Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files

被引:21
|
作者
Zubizarreta-Macho, Alvaro [1 ]
Mena Alvarez, Jesus [1 ]
Albaladejo Martinez, Alberto [2 ]
Jose Segura-Egea, Juan [3 ]
Caviedes Brucheli, Javier [4 ]
Agustin-Panadero, Ruben [5 ]
Lopez Piriz, Roberto [6 ]
Alonso-Ezpeleta, Oscar [7 ]
机构
[1] Alfonso X El Sabio Univ, Fac Hlth Sci, Dept Endodont, Madrid 28691, Spain
[2] Univ Salamanca, Sch Med, Dept Dent, E-37008 Salamanca, Spain
[3] Univ Seville, Fac Dent, C Avicena S-N, E-41009 Seville, Spain
[4] Pontificia Univ Javeriana, CIO, Bogota 1101, Colombia
[5] Univ Valencia, Fac Med & Dent, Dept Stomatol, Valencia 46010, Spain
[6] Inst Mat Sci Madrid, Super Council Sci Invest, Madrid 28222, Spain
[7] Univ Zaragoza, Sch Hlth Sci, Dept Endodont, Aragorn 22006, Spain
关键词
endodontics; cyclic fatigue; pecking motion; endodontic rotary files; NiTi rotary files; PROTAPER UNIVERSAL INSTRUMENTS; NICKEL-TITANIUM FILES; ROTATIONAL SPEED; SEPARATION; RECIPROC; OPERATOR; DEFECTS; SYSTEMS; CANALS; LIFE;
D O I
10.3390/jcm9010045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To analyze the influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files. Material and Methods: Sixty PlexV 25.06 endodontic rotary files were selected and distributed into three groups: 30 movements/min (n = 20), 60 movements/min (n = 20), and 120 movements/min (n = 20). A dynamic cyclic fatigue device was designed using Computer Aided Design/ Computer Aided Engineering (CAD/CAE) technology and manufactured by 3D impressions to simulate the pecking motion performed by an operator. Failures of the endodontic rotary files were detected by a Light-Emitting Diode (LED)/Light-Dependent Resistor (LDR) system controlled by an Arduino-Driver complex and management software. Endodontic rotary files were tested on an artificial root canal manufactured by wire electrical discharge machining (EDM), with similar dimensions to those of the instrument under examination. Endodontic rotary files were used following the manufacturer's recommendations. The results were analyzed by ANOVA and Weibull statistics. Results: All pairwise comparisons revealed statistically significant differences in all three variables, except for the difference in the number of cycles between the groups with 60 and 120 movements/min (p = 0.298). The scale distribution parameter of Weibull statistics showed statistically significant differences in all three variables, except for the differences in the number of cycles between groups with 30 and 60 movements/min (p = 0.0722). No statistically significant differences in the three variables were observed for the shape distribution parameter. Conclusion: A low frequency of pecking motion is recommended to reduce the risk of failure of endodontic rotary files associated with cyclic fatigue.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Influence of clinical usage of GT and GTX files on cyclic fatigue resistance
    Arias, A.
    Perez-Higueras, J. J.
    de la Macorra, J. C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (03) : 257 - 263
  • [42] Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files
    Pedulla, Eugenio
    Carlesi, Teocrito
    Pappalardo, Alfio
    Canova, Francesco Saverio
    Malagnino, Vito Antonio
    La Rosa, Giusy Rita Maria
    Generali, Luigi
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (01):
  • [43] Significance of heat treatment on the mechanical and fatigue properties of NiTi endodontic rotary files
    Naghibi, Mohaddeseh Sadat
    Shahmir, Hamed
    Omidian, Sajjad
    Mirzavand-Borujeni, Ali
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2025, 35 : 6497 - 6504
  • [44] Blue Treatment Enhances Cyclic Fatigue Resistance of Vortex Nickel-Titanium Rotary Files
    Plotino, Gianluca
    Grande, Nicola M.
    Cotti, Elisabetta
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1451 - 1453
  • [45] Novel Electronic Device to Quantify the Cyclic Fatigue Resistance of Endodontic Reciprocating Files after Using and Sterilization
    Zubizarreta-Macho, Alvaro
    Alonso-Ezpeleta, Oscar
    Albaladejo Martinez, Alberto
    Faus Matoses, Vicente
    Caviedes Brucheli, Javier
    Agustin-Panadero, Ruben
    Mena Alvarez, Jesus
    Vizmanos Martinez-Berganza, Fernando
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [46] Influence of Different Manufacturing Methods on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Rodrigues, Renata C. V.
    Lopes, Helio P.
    Elias, Carlos N.
    Amaral, Georgiana
    Vieira, Victor T. L.
    De Martin, Alexandre S.
    JOURNAL OF ENDODONTICS, 2011, 37 (11) : 1553 - 1557
  • [47] THE EFFECTS OF CYCLICAL AXIAL MOTION ON ROTARY ENDODONTIC INSTRUMENT FATIGUE
    DEDERICH, DN
    ZAKARIASEN, KL
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 61 (02): : 192 - 196
  • [48] EFFECTS OF CYCLICAL AXIAL MOTION ON ROTARY ENDODONTIC INSTRUMENT FATIGUE
    DEDERICH, D
    ZAKARIASEN, KL
    JOURNAL OF DENTAL RESEARCH, 1983, 62 : 174 - 174
  • [49] Influence of Continuous or Reciprocating Motion on Cyclic Fatigue Resistance of 4 Different Nickel-Titanium Rotary Instruments
    Pedulla, Eugenio
    Grande, Nicola M.
    Plotino, Gianluca
    Gambarini, Gianluca
    Rapisarda, Ernesto
    JOURNAL OF ENDODONTICS, 2013, 39 (02) : 258 - 261
  • [50] Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?
    Emmanuel João Nogueira Leal Silva
    Rafael Santos Attademo
    Marcia Cristina Dutra da Silva
    Karem Paula Pinto
    Henrique dos Santos Antunes
    Victor Talarico Leal Vieira
    Clinical Oral Investigations, 2021, 25 : 3691 - 3698