Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files

被引:3
|
作者
Pedulla, Eugenio [1 ]
Carlesi, Teocrito [2 ,3 ]
Pappalardo, Alfio
Canova, Francesco Saverio [1 ]
Malagnino, Vito Antonio [3 ]
La Rosa, Giusy Rita Maria [1 ]
Generali, Luigi [4 ]
机构
[1] Univ Catania, Dept Gen Surg & Med Surg Specialties, Catania, Italy
[2] Univ Chieti Pescara G DAnnunzio, Fac Med & Surg, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[3] Univ Chieti Pescara G DAnnunzio, Fac Med & Surg, Dept Innovat Technol Med & Dent, Chieti, Italy
[4] Univ Modena & Reggio Emilia, Dept Surg Med Dent & Morphol Sci Transplant Surg, Modena, Italy
来源
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH | 2024年 / 10卷 / 01期
关键词
dynamic cyclic fatigue; endodontics; Mtwo Minimal; pecking motion; RECIPROC BLUE; WAVEONE GOLD; HYFLEX EDM; INSTRUMENTS; RESISTANCE; MOTION; SPEED;
D O I
10.1002/cre2.811
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature.Materials and Methods: Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35 degrees C (+/- 1 degrees C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05).Results: The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05).Conclusion: Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (11) : 1034 - 1039
  • [2] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Lee, S. W.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1100 - 1100
  • [3] Effect from Cyclic Fatigue of Nickel-Titanium Rotary Files on Torsional Resistance
    Kim, Ju-Yeong
    Cheung, Gary Shun-Pan
    Park, Se-Hee
    Ko, Dae-Cheol
    Kim, Jin-Wook
    Kim, Hyeon-Cheol
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 527 - 530
  • [4] Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
    Yao, JH
    Schwartz, SA
    Beeson, TJ
    JOURNAL OF ENDODONTICS, 2006, 32 (01) : 55 - 57
  • [5] Effect of reciprocation usage of nickel-titanium rotary files on the cyclic fatigue resistance
    Lee, WooCheol
    Hwang, You-Jeong
    You, Sung-Yeop
    Kim, Hyeon-Cheol
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 146 - 150
  • [6] The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue
    Zinelis, Spiros
    Darabara, Myrsini
    Takase, Toshiyuki
    Ogane, Kaoru
    Papadimitriou, George D.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (06): : 843 - 847
  • [7] Cyclic Fatigue and Fracture Characteristics of Ground and Twisted Nickel-Titanium Rotary Files
    Kim, Hyeon-Cheol
    Yum, Jiwan
    Hur, Bock
    Cheung, Gary Shun-Pan
    JOURNAL OF ENDODONTICS, 2010, 36 (01) : 147 - 152
  • [8] Finite element study of the fatigue behaviour of nickel-titanium endodontic files utilised with pecking motion technique
    Kokan, Eyup Can
    Atik, Yasin
    Ozupek, Sebnem
    Podnos, Evgeny
    Erisen, Raif
    AUSTRALIAN ENDODONTIC JOURNAL, 2024, 50 (01) : 97 - 109
  • [9] Blue Treatment Enhances Cyclic Fatigue Resistance of Vortex Nickel-Titanium Rotary Files
    Plotino, Gianluca
    Grande, Nicola M.
    Cotti, Elisabetta
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1451 - 1453
  • [10] Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
    Abuhulaibah, Hind F.
    AbuMostafa, Ammar
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020