Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files

被引:3
|
作者
Pedulla, Eugenio [1 ]
Carlesi, Teocrito [2 ,3 ]
Pappalardo, Alfio
Canova, Francesco Saverio [1 ]
Malagnino, Vito Antonio [3 ]
La Rosa, Giusy Rita Maria [1 ]
Generali, Luigi [4 ]
机构
[1] Univ Catania, Dept Gen Surg & Med Surg Specialties, Catania, Italy
[2] Univ Chieti Pescara G DAnnunzio, Fac Med & Surg, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[3] Univ Chieti Pescara G DAnnunzio, Fac Med & Surg, Dept Innovat Technol Med & Dent, Chieti, Italy
[4] Univ Modena & Reggio Emilia, Dept Surg Med Dent & Morphol Sci Transplant Surg, Modena, Italy
来源
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH | 2024年 / 10卷 / 01期
关键词
dynamic cyclic fatigue; endodontics; Mtwo Minimal; pecking motion; RECIPROC BLUE; WAVEONE GOLD; HYFLEX EDM; INSTRUMENTS; RESISTANCE; MOTION; SPEED;
D O I
10.1002/cre2.811
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature.Materials and Methods: Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35 degrees C (+/- 1 degrees C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05).Results: The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05).Conclusion: Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Low Environmental Temperature Influences the Fatigue Resistance of Nickel-titanium Files
    Shen, Ya
    Huang, Xiangya
    Wang, Zhejun
    Wei, Xi
    Haapasalo, Markus
    JOURNAL OF ENDODONTICS, 2018, 44 (04) : 626 - 629
  • [22] Nickel-titanium files in endodontics: development, improvement, and modifications of nickel-titanium alloy
    Zivkovic, Slavoljub
    Jovanovic-Medojevic, Milica
    Neskovic, Jelena
    Popovic-Bajic, Marijana
    VOJNOSANITETSKI PREGLED, 2023, 80 (03) : 262 - 269
  • [23] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files (vol 48, pg 1100, 2015)
    Lee, S. H.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (02) : 220 - 220
  • [24] Influence of Different Heat Treatments on Torsional and Cyclic Fatigue Resistance of Nickel-Titanium Rotary Files: A Comparative Study
    Gambarini, Gianluca
    Cicconetti, Andrea
    Di Nardo, Dario
    Miccoli, Gabriele
    Zanza, Alessio
    Testarelli, Luca
    Seracchiani, Marco
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [25] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [26] A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments
    Plotino, Gianluca
    Grande, Nicola M.
    Cordaro, Massimo
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1469 - 1476
  • [27] Cyclic fatigue of new nickel-titanium instruments in artificial canals with single and double curvature
    Miglio, Cristiano
    Grande, Nicola M.
    Plotino, Gianluca
    Milana, Valerio
    Testarelli, Luca
    Gambarini, Gianluca
    GIORNALE ITALIANO DI ENDODONZIA, 2012, 26 (03): : 106 - 110
  • [28] Effect of Glide Path Creating on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Nickel-titanium Files: A Laboratory Study
    Ozyurek, Taha
    Uslu, Gulsah
    Yilmaz, Koray
    Gundogar, Mustafa
    JOURNAL OF ENDODONTICS, 2018, 44 (06) : 1033 - 1037
  • [29] A method to assess rotary nickel-titanium files
    Svec, TA
    Powers, JM
    JOURNAL OF ENDODONTICS, 2000, 26 (09) : 517 - 518
  • [30] Impacts of NaOCl and Irritrol irrigation solutions with/without autoclave sterilisation on the cyclic fatigue resistance of different nickel-titanium files
    Kermeoglu, Fatma
    Abduljalil, Mohamad
    AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (03) : 392 - 399