A DEMOUNTABLE PRECAST REINFORCED CONCRETE BUILDING SYSTEM OF MULTI-STORY BUILDINGS

被引:0
|
作者
Witzany, Jiri [1 ]
Zigler, Radek [1 ]
Cejka, Tomas [1 ]
Polak, Ales [1 ]
机构
[1] Czech Tech Univ, Dept Bldg Struct, Prague, Czech Republic
关键词
Frame; Dynamic characteristics; Bearings; Natural oscillation; Forced oscillation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The demountable precast reinforced concrete building system consists of bar and thin-walled units allowing designing hybrid integrated systems of multi-storey buildings. The system's characteristic property are demountable, self-rectifiable and dry joints enabling assembly without wet processes and, in case of need, the disassembly and relocation of the structure. The system applies special mounting, the joint of prestressed hollow core floor units and the load-bearing structure by steel pins additionally embedded in the hollow cores. The article presents the results of experimental research into the major parts and joints of the load-bearing system and the verification of the load-bearing system's prototype exposed to static load tests with an example of the load-bearing system's assembly and disassembly.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [41] Experimental study on multi-story precast concrete shear walls with horizontal joints restrained from slipping
    Matsumoto, Toshio
    Nishihara, Hiroshi
    Transactions of the Japan Concrete Institute, 1999, 21 : 335 - 342
  • [42] Continuous time parameter estimation of multi-story buildings
    Ma, David
    Xu, Ning-Shou
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2007, PTS 1 AND 2, 2007, 6529
  • [43] Effects of Story-by-Story Post-Tensioning on Multi-Story Buildings
    Guo, Guohui
    Joseph, Leonard M.
    Darwin, David
    ACI STRUCTURAL JOURNAL, 2013, 110 (04) : 649 - 657
  • [44] Multi-story logistics buildings in precast design for self-driving robots: Construction in earthquake zone 2
    Molter, Matthias
    Betonwerk und Fertigteil-Technik/Concrete Plant and Precast Technology, 2019, 85 (02): : 28 - 29
  • [45] Floor Determination for Positioning in Multi-story Building
    Abd Rahman, Mohd Amiruddin
    Dashti, Marzieh
    Zhang, Jie
    2014 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC), 2014, : 2540 - 2545
  • [46] Effects of story-by-story post-tensioning on multi-story buildings
    1600, American Concrete Institute (110):
  • [47] Estimation of earthquake induced story hysteretic energy of multi-Story buildings
    Wang, Feng
    Zhang, Ning
    Huang, Zhiyu
    EARTHQUAKES AND STRUCTURES, 2016, 11 (01) : 165 - 178
  • [48] Unsymmetricity effects on seismic performance of multi-story buildings
    Pandian, Antony Vimal Paul
    Arunachalam, Krishna Prakash
    Bahrami, Alireza
    Romero, Lenin Miguel Bendezu
    Avudaiappan, Siva
    Awoyera, Paul O.
    DISCOVER APPLIED SCIENCES, 2024, 6 (09)
  • [49] Building Construction from Precast Reinforced Concrete
    不详
    BAUINGENIEUR, 2014, 89 : A22 - A22
  • [50] SEISMIC STRUCTURAL ANALYSIS OF MULTI-STORY CONCRETE BUILDING BASED ON HALABJA 2017 EARTHQUAKE
    Mohammed, Aymen R.
    Abdulwahed, Larah R.
    Rashid, Bushra