A DEMOUNTABLE PRECAST REINFORCED CONCRETE BUILDING SYSTEM OF MULTI-STORY BUILDINGS

被引:0
|
作者
Witzany, Jiri [1 ]
Zigler, Radek [1 ]
Cejka, Tomas [1 ]
Polak, Ales [1 ]
机构
[1] Czech Tech Univ, Dept Bldg Struct, Prague, Czech Republic
关键词
Frame; Dynamic characteristics; Bearings; Natural oscillation; Forced oscillation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The demountable precast reinforced concrete building system consists of bar and thin-walled units allowing designing hybrid integrated systems of multi-storey buildings. The system's characteristic property are demountable, self-rectifiable and dry joints enabling assembly without wet processes and, in case of need, the disassembly and relocation of the structure. The system applies special mounting, the joint of prestressed hollow core floor units and the load-bearing structure by steel pins additionally embedded in the hollow cores. The article presents the results of experimental research into the major parts and joints of the load-bearing system and the verification of the load-bearing system's prototype exposed to static load tests with an example of the load-bearing system's assembly and disassembly.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [31] Efficiency in the delivery of multi-story timber buildings
    Ruuska, Antti
    Hakkinen, Tarja
    SUSTAINABLE BUILT ENVIRONMENT TALLINN AND HELSINKI CONFERENCE SBE16 BUILD GREEN AND RENOVATE DEEP, 2016, 96 : 190 - 201
  • [32] Damage detection of multi-story buildings with torsion
    Hamamoto, T
    Tanohata, T
    Kondo, I
    STRUCTURAL SAFETY AND RELIABILITY, VOLS. 1-3, 1998, : 339 - 347
  • [33] Automated construction planning for multi-story buildings
    Department of Civil Engineering and Construction, 120H CME Building, North Dakota State University, Fargo, ND 58105
    ASCE, Construction Institute, CI; IAARC; Lean Construction Institute; University of California, Berkely: PoPSyCal, 1600, 1213-1222 (2005):
  • [34] Problems associated with pipework in multi-story buildings
    Williams, Campbell
    Australian refrigeration, Air conditioning and heating, 1990, 44 (09):
  • [35] HYDRONIC CONTROLS FOR MULTI-STORY BUILDINGS.
    Boss, William
    HPAC Heating, Piping, Air Conditioning, 1986, 58 (12): : 123 - 124
  • [36] Efficient seismic analysis of multi-story buildings
    Lee, DG
    Kim, HC
    STRUCTURAL ENGINEERING AND MECHANICS, 1996, 4 (05) : 497 - 511
  • [37] Experimental study on the behavior of reinforced concrete buildings with precast floor system
    López-Bátiz, O
    Silva-Olivera, H
    INNOVATIONS IN DESIGN WITH EMPHASIS ON SEISMIC, WIND, AND ENVIRONMENTAL LOADING: QUALITY CONTROL AND INNOVATIONS IN MATERIALS/HOT-WEATHER CONCRETING, 2002, 209 : 571 - 591
  • [38] Performance of a multi-story reinforced concrete flat plate slab building with and without steel bracing under Seismic loading
    Ibrahim S. I. Harba
    Abdulkhalik J. Abdulridha
    Ahmed A. M. Al-Shaar
    Asian Journal of Civil Engineering, 2025, 26 (3) : 1321 - 1338
  • [39] A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building
    Wang, Y.
    Dong, Y. -L.
    Li, B.
    Zhou, G. -C.
    FIRE SAFETY JOURNAL, 2013, 61 : 232 - 242
  • [40] Analysis on the Exhaust Air Recirculation of the Ventilation System in Multi-Story Building
    Park, Seonghyun
    Park, Hyungyu
    Seo, Janghoo
    APPLIED SCIENCES-BASEL, 2021, 11 (10):