A DEMOUNTABLE PRECAST REINFORCED CONCRETE BUILDING SYSTEM OF MULTI-STORY BUILDINGS

被引:0
|
作者
Witzany, Jiri [1 ]
Zigler, Radek [1 ]
Cejka, Tomas [1 ]
Polak, Ales [1 ]
机构
[1] Czech Tech Univ, Dept Bldg Struct, Prague, Czech Republic
关键词
Frame; Dynamic characteristics; Bearings; Natural oscillation; Forced oscillation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The demountable precast reinforced concrete building system consists of bar and thin-walled units allowing designing hybrid integrated systems of multi-storey buildings. The system's characteristic property are demountable, self-rectifiable and dry joints enabling assembly without wet processes and, in case of need, the disassembly and relocation of the structure. The system applies special mounting, the joint of prestressed hollow core floor units and the load-bearing structure by steel pins additionally embedded in the hollow cores. The article presents the results of experimental research into the major parts and joints of the load-bearing system and the verification of the load-bearing system's prototype exposed to static load tests with an example of the load-bearing system's assembly and disassembly.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [1] Precast reinforced concrete demountable system of multi-storey buildings
    Witzany, J.
    Zigler, R.
    Polak, A.
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1300 - 1305
  • [2] Analysis on columns of multi-story buildings in precast concrete during the transitory stage
    Otrente, Joao Francisco
    Ferreira, Marcelo de Araujo
    Rocha, Arthur Lima
    Catoia, Bruna
    MATERIA-RIO DE JANEIRO, 2022, 27 (02):
  • [3] A new shallow precast/prestressed concrete floor system for multi-story buildings in low seismic zones
    Morcous, George
    Henin, Eliya
    Fawzy, Faten
    Lafferty, Mark
    Tadros, Maher K.
    ENGINEERING STRUCTURES, 2014, 60 : 287 - 299
  • [4] Seismic Vulnerability Assessment of Existing Multi-Story Reinforced Concrete Buildings in Egypt
    Said A. El-Kholy
    Mohamed S. El-Assaly
    Medhat Maher
    Arabian Journal for Science and Engineering, 2012, 37 : 341 - 355
  • [5] Seismic Vulnerability Assessment of Existing Multi-Story Reinforced Concrete Buildings in Egypt
    El-Kholy, Said A.
    El-Assaly, Mohamed S.
    Maher, Medhat
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (02): : 341 - 355
  • [6] Effect of seismic torsional component on nonlinear behavior of reinforced concrete multi-story buildings
    Ouazir, Abderrahmane
    Hadjadj, Asma
    Ouazir, Mansour
    Boukendakji, Mustapha
    Gasmi, Hatem
    STRUCTURAL ENGINEERING AND MECHANICS, 2024, 91 (04) : 349 - 355
  • [7] The behavior of cross-laminated timber and reinforced concrete floors in a multi-story building
    Bahrami, Alireza
    Edas, Martin
    Magnenat, Kevin
    Noren, Johan
    INTERNATIONAL JOURNAL OF ADVANCED AND APPLIED SCIENCES, 2022, 9 (06): : 43 - 50
  • [8] Mid-Column Pounding of Multi-Story Reinforced Concrete Buildings Considering Soil Effects
    Shakya, Kabir
    Wijeyewickrema, Anil C.
    ADVANCES IN STRUCTURAL ENGINEERING, 2009, 12 (01) : 71 - 85
  • [9] Numerical study of demountable shear wall system for multistory precast concrete buildings
    Naserpour, Afshin
    Fathi, Mojtaba
    STRUCTURES, 2021, 34 : 700 - 715
  • [10] DEVELOPMENTS IN MULTI-STORY BUILDINGS
    HARYOTT, RB
    GLOVER, MJ