Monitoring free light chains in serum using mass spectrometry

被引:38
|
作者
Barnidge, David R. [1 ]
Dispenzieri, Angela [1 ,2 ]
Merlini, Giampaolo [3 ]
Katzmann, Jerry A. [1 ]
Murray, David L. [1 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] IRCCS Policlin S Matteo, Biotechnol Res Labs, Pavia, Italy
关键词
free light chains; kappa; l; mass spectrometry; microflow LC-ESI-Q-TOF MS; monoclonal; INTACT MONOCLONAL-ANTIBODIES; ABSOLUTE QUANTIFICATION; POSTTRANSLATIONAL MODIFICATIONS; ELECTROSPRAY-IONIZATION; PROTEIN; IDENTIFICATION; MS;
D O I
10.1515/cclm-2015-0917
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Serum immunoglobulin free light chains (FLC) are secreted into circulation by plasma cells as a by-product of immunoglobulin production. In a healthy individual the population of FLC is polyclonal as no single cell is secreting more FLC than the total immunoglobulin secreting cell population. In a person with a plasma cell dyscrasia, such as multiple myeloma (MM) or light chain amyloidosis (AL), a clonal population of plasma cells secretes a monoclonal light chain at a concentration above the normal polyclonal background. Methods: We recently showed that monoclonal immunoglobulin rapid accurate mass measurement (miRAMM) can be used to identify and quantify a monoclonal light chain (LC) in serum and urine above the polyclonal background. This was accomplished by reducing immunoglobulin disulfide bonds releasing the LC to be analyzed by microLC-ESI-Q-TOF mass spectrometry. Here we demonstrate that the methodology can also be applied to the detection and quantification of FLC by analyzing a non-reduced sample. Results: Proof of concept experiments were performed using purified FLC spiked into normal serum to assess linearity and precision. In addition, a cohort of 27 patients with AL was analyzed and miRAMM was able to detect a monoclonal FLC in 23 of the 27 patients that had abnormal FLC values by immunonephelometry. Conclusions: The high resolution and high mass measurement accuracy provided by the mass spectrometry based methodology eliminates the need for kappa/lambda ratios as the method can quantitatively monitor the abundance of the kappa and lambda polyclonal background at the same time it measures the monoclonal FLC.
引用
收藏
页码:1073 / 1083
页数:11
相关论文
共 50 条
  • [1] Quantitative Measurement of Immunoglobulins and Free Light Chains Using Mass Spectrometry
    VanDuijn, Martijn M.
    Jacobs, Joannes F. M.
    Wevers, Ron A.
    Engelke, Udo F.
    Joosten, Irma
    Luider, Theo M.
    ANALYTICAL CHEMISTRY, 2015, 87 (16) : 8268 - 8274
  • [2] Serum free light chains for monitoring multiple myeloma
    Tate, J
    Mollee, P
    Gill, D
    BRITISH JOURNAL OF HAEMATOLOGY, 2005, 128 (03) : 405 - 406
  • [3] Serum free light chains for monitoring multiple myeloma
    Mead, GP
    Carr-Smith, HD
    Drayson, MT
    Morgan, GJ
    Child, JA
    Bradwell, AR
    BRITISH JOURNAL OF HAEMATOLOGY, 2004, 126 (03) : 348 - 354
  • [4] Myeloma monitoring using serum free light chains in patients with renal involvment
    Flisar, Ziva
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 256 - 256
  • [5] Serum free light chains for monitoring multiple myeloma - Response
    Mead, GP
    Carr-Smith, H
    Drayson, MT
    Morgan, GT
    Child, AJ
    BRITISH JOURNAL OF HAEMATOLOGY, 2005, 128 (03) : 406 - 407
  • [6] Detection and monitoring of nonsecretory myeloma using an assay for free light chains in serum.
    Bradwell, AR
    Carr-Smith, HD
    Smith, L
    Mead, GP
    CLINICAL CHEMISTRY, 2001, 47 (06) : A43 - A44
  • [7] Serum free light chains
    Forsyth, Julia
    Hill, Peter
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 444 - 445
  • [8] Monitoring of Systemic Light-Chain Amyloidosis Patients Using Mass Spectrometry (MinSight) in Serum
    Mouktadi, Zarouki
    Diemont, Paul-Henri
    Di Stefano, Luciano
    Bonifay, Vincent
    Bender, Sebastien
    Pascal, Virginie
    Sirac, Christophe
    Roussel, Murielle
    Dubroc, Caroline Rouge
    Sonigo, Pierre
    BLOOD, 2023, 142
  • [9] Quantitation of Serum Free Light Chains
    Bakker, Andries J.
    Bierma-Ram, Ageeth
    Elderman-van der Werf, Coby
    Strijdhaftig, Marcia L.
    van Zanden, Jelmer J.
    CLINICAL CHEMISTRY, 2009, 55 (08) : 1585 - 1587
  • [10] Serum free light chains in the diagnosis and monitoring of patients with plasma cell dyscrasias
    Mayo, Mary M.
    Johns, Gretchen Schaef
    KIDNEY IN PLASMA CELL DYSCRASIAS, 2007, 153 : 44 - 65