An assessment of the quality of optical coherence tomography image acquisition

被引:5
|
作者
Zago, Elder Iarossi [1 ]
Samdani, Abdul Jawwad [1 ]
Pereira, Gabriel Tensol Rodrigues [1 ]
Vergara-Martel, Armando [1 ]
Alaiti, Mohamad Amer [2 ,3 ]
Dallan, Luis Augusto [1 ]
Pizzato, Patricia Ely [1 ]
Zimin, Vladislav [1 ]
Fares, Anas [1 ]
Bezerra, Hiram G. [1 ]
机构
[1] Univ Hosp Cleveland Med Ctr, Harrington Heart & Vasc Inst, Cardiovasc Imaging Core Lab, 11100 Euclid Ave,Lakeside Bldg,Room 3113, Cleveland, OH 44106 USA
[2] Univ Texas Southwestern, Dallas, TX USA
[3] VA North Texas Healthcare Syst, Dallas, TX USA
来源
关键词
Image acquisition; Optical coherence tomography; Intravascular imaging; PERCUTANEOUS CORONARY INTERVENTION; MOLECULAR-WEIGHT DEXTRAN; GUIDE DECISION-MAKING; CLINICAL-APPLICATIONS; DOCUMENT; SAFETY; OPTIMIZATION; FEASIBILITY; TERMINOLOGY; METHODOLOGY;
D O I
10.1007/s10554-020-01795-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optical coherence tomography (OCT) provides excellent image resolution, however OCT optimal acquisition is essential but could be challenging owing to several factors. We sought to assess the quality of OCT pullbacks and identify the causes of suboptimal image acquisition. We evaluated 784 (404 pre-PCI; 380 post-PCI) coronary pullbacks from an anonymized OCT database from our Cardiovascular Imaging Core Laboratory. Imaging of the region-of-interest (ROI-lesion or stented segment plus references) was incomplete in 16.1% pullbacks, caused by pullback starting too proximal (63.7%), inappropriate pullback length (17.1%) and pullback starting too distal (11.4%). The quality of image acquisition was excellent in 36.3% pullbacks; whereas 4% pullbacks were unanalyzable. Pullback quality was most commonly affected by poor blood displacement from inadequate contrast volume (27.4%) or flow (25.6%), followed by artifacts (24.1%). Acquisition mode was 'High-Resolution' (54 mm) in 74.4% and 'Survey' (75 mm) in 25.6% of cases. The 54 mm mode was associated with incomplete ROI imaging (p = 0.020) and inadequate contrast volume (p = 0.035). We observed a substantial frequency of suboptimal image acquisition and identified its causes, most of which can be addressed with minor modifications during the procedure, ultimately improving patient outcomes.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 50 条
  • [21] Factors influencing image quality in Tibetan children by optical coherence tomography
    Yao, Yao
    Liu, Jiawen
    Li, Lei
    Chen, Weiwei
    Meng, Zhaojun
    Fu, Jing
    FRONTIERS IN MEDICINE, 2025, 12
  • [22] Effect of night work on image quality of optical coherence tomography angiography
    Abrishami, Mojtaba
    Fadakar, Pouran
    Mirghorbani, Masoud
    Masoumi, Ahmad
    Hassanzadeh, Samira
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (04): : 438 - 441
  • [23] Image Quality in Adaptive Optics Optical Coherence Tomography of Diabetic Patients
    Brunner, Elisabeth
    Kunze, Laura
    Drexler, Wolfgang
    Pollreisz, Andreas
    Pircher, Michael
    DIAGNOSTICS, 2025, 15 (04)
  • [24] Safety and Feasibility of Non-occlusion Image Acquisition Technique for Optical Coherence Tomography
    Kataiwa, Hideaki
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Takarada, Shigeho
    Nakamura, Nobuo
    Hirata, Kumiko
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 197I - 197I
  • [25] Fast optical coherence tomography angiography image acquisition and reconstruction pipeline for skin application
    Liao, Jinpeng
    Yang, Shufan
    Zhang, Tianyu
    Li, Chunhui
    Huang, Zhihong
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (08) : 3899 - 3913
  • [26] Safety and usefulness of non-occlusion image acquisition technique for optical coherence tomography
    Kataiwa, Hideaki
    Tanaka, Atsushi
    Kitabata, Hironori
    Imanishi, Toshio
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2008, 72 (09) : 1536 - 1537
  • [27] Image Averaging, a Powerful Tool in Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Waheed, Nadia K.
    Duker, Jay S.
    JAMA OPHTHALMOLOGY, 2017, 135 (11) : 1204 - 1205
  • [28] Image Distortion of Optical Coherence Tomography
    安源
    姚建铨
    Transactions of Tianjin University, 2004, (01) : 81 - 84
  • [29] OPTICAL COHERENCE TOMOGRAPHY IMAGE SEGMENTATION
    Duan, Jinming
    Tench, Christopher
    Gottlob, Irene
    Proudlock, Frank
    Bai, Li
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 4278 - 4282
  • [30] Evaluation of potential image acquisition pitfalls during optical coherence tomography and their influence on retinal image segmentation
    Somfai, Gabor Mark
    Salinas, Harry M.
    Puliafito, Carmen A.
    Fernandez, Delia Cabrera
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)