Study of truncated cone filters using GEANT4

被引:0
|
作者
Himukai, T
Takada, Y
Kohno, R
机构
[1] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 305, Japan
[2] Natl Inst Radiol Sci, Chiba 260, Japan
关键词
D O I
10.1118/1.1998077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A ridge filter has been used for proton therapy to form a spread‐out Bragg peak (SOBP). As the SOBP width becomes larger and the distal falloff becomes smaller, more number of ridge elements is required for the ridge filter. Then extremity of the ridge filter becomes too sharp to machine for large SOBP widths. Since an aperture collimator shapes the proton beam, beam mixing by adjacent ridges is affected by scattering in the ridge elements in the peripheral region. Namely, the proximal part of the SOBP begins to fall at depth deeper than the expected depth. A purpose in this study is to achieve uniformities of both the SOBP and the lateral dose distribution by improving a conventional ridge filter. Method and Materials: We have designed a two‐dimensional array of truncated cone filters (TCF) in honeycomb structure. Since extremity of the TCF is moderate compared with a conventional ridge filter (CRF), manufacturing the TCF is relatively easy. Thus the TCF enables selection of lighter material with smaller scattering effect. In this study, a CRF (aluminum alloy) and a TCF (Lucite) with a SOBP width of 60mm were designed for a 155MeV proton beam. We simulated dose distribution in water for a therapeutic beam with GEANT4 to investigate the influence of both ridge filters. Results: While a few% dose decrease is observed in the proximal part of the SOBP region for the CRF, the dose distribution is more uniform in entire of SOBP region for the TCF. Conclusion: We designed a two‐dimensional array of TCF. It is easier to machine the TCF for SOBP filters with large SOBP widths especially for low‐energy protons. Overall dose uniformity of the SOBP region in the TCF was improved as compared with the CRF. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2030 / 2031
页数:2
相关论文
共 50 条
  • [41] Calorimeter studies with Geant4
    de Freitas, PM
    PHYSICS AND EXPERIMENTS WITH FUTURE LINEAR E(PLUS) E(MINUS) COLLIDERS, 2001, 578 : 658 - 661
  • [42] GEANT4 APPLICATIONS IN SPACE
    Asai, Makoto
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 719 - 728
  • [43] Analysis Tools in Geant4
    Hrivnacova, Ivana
    Barrand, Guy
    26TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS, CHEP 2023, 2024, 295
  • [44] Geant4 in Scientific Literature
    Pia, Maria Grazia
    Basaglia, Tullio
    Bell, Zane W.
    Dressendorfer, Paul V.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 189 - +
  • [45] An overview of the Geant4 toolkit
    Apostolakis, John
    Wright, Dennis H.
    HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 1 - +
  • [46] Study on GEANT4 code applications to dose calculation using imaging data
    Jeong Ok Lee
    Jeong Ku Kang
    Jhin Kee Kim
    Hyeong Cheol Kwon
    Jung Soo Kim
    Bu Gil Kim
    Dong Hyeok Jeong
    Journal of the Korean Physical Society, 2015, 67 : 195 - 198
  • [47] THE STUDY OF RESPONSE OF WIDE BAND GAP SEMICONDUCTOR DETECTORS USING THE GEANT4
    Hussain, Riaz
    Mirza, Sikander M.
    Mirza, Nasir M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 242 - 248
  • [48] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, A
    Pokorski, W
    Ranjard, F
    Robbe, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1665 - 1668
  • [49] Simulation Validation Epistemics in a Geant4 Case Study
    Basaglia, Tullio
    Han, Min Cheol
    Hoff, Gabriela
    Kim, Chan Hyeong
    Kim, Sung Hun
    Pia, Maria Grazia
    Saracco, Paolo
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [50] GEANT4 for breast dosimetry: parameters optimization study
    Fedon, C.
    Longo, F.
    Mettivier, G.
    Longo, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16): : N311 - N323