Study of truncated cone filters using GEANT4

被引:0
|
作者
Himukai, T
Takada, Y
Kohno, R
机构
[1] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 305, Japan
[2] Natl Inst Radiol Sci, Chiba 260, Japan
关键词
D O I
10.1118/1.1998077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A ridge filter has been used for proton therapy to form a spread‐out Bragg peak (SOBP). As the SOBP width becomes larger and the distal falloff becomes smaller, more number of ridge elements is required for the ridge filter. Then extremity of the ridge filter becomes too sharp to machine for large SOBP widths. Since an aperture collimator shapes the proton beam, beam mixing by adjacent ridges is affected by scattering in the ridge elements in the peripheral region. Namely, the proximal part of the SOBP begins to fall at depth deeper than the expected depth. A purpose in this study is to achieve uniformities of both the SOBP and the lateral dose distribution by improving a conventional ridge filter. Method and Materials: We have designed a two‐dimensional array of truncated cone filters (TCF) in honeycomb structure. Since extremity of the TCF is moderate compared with a conventional ridge filter (CRF), manufacturing the TCF is relatively easy. Thus the TCF enables selection of lighter material with smaller scattering effect. In this study, a CRF (aluminum alloy) and a TCF (Lucite) with a SOBP width of 60mm were designed for a 155MeV proton beam. We simulated dose distribution in water for a therapeutic beam with GEANT4 to investigate the influence of both ridge filters. Results: While a few% dose decrease is observed in the proximal part of the SOBP region for the CRF, the dose distribution is more uniform in entire of SOBP region for the TCF. Conclusion: We designed a two‐dimensional array of TCF. It is easier to machine the TCF for SOBP filters with large SOBP widths especially for low‐energy protons. Overall dose uniformity of the SOBP region in the TCF was improved as compared with the CRF. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2030 / 2031
页数:2
相关论文
共 50 条
  • [21] A CAD interface for GEANT4
    C. M. Poole
    I. Cornelius
    J. V. Trapp
    C. M. Langton
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 329 - 334
  • [22] PIXE simulation in Geant4
    Mantero, A.
    Ben Abdelouahed, H.
    Champion, C.
    El Bitar, Z.
    Francis, Z.
    Gueye, P.
    Incerti, S.
    Ivanchenko, V.
    Maire, M.
    X-RAY SPECTROMETRY, 2011, 40 (03) : 135 - 140
  • [23] Geant4 Anthropomorphic Phantoms
    Guatelli, Susanna
    Mascialino, Barbara
    Pia, Maria Grazia
    Pokorski, Witold
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1359 - 1362
  • [24] PIXE Simulation With Geant4
    Pia, Maria Grazia
    Weidenspointner, Georg
    Augelli, Mauro
    Quintieri, Lina
    Saracco, Paolo
    Sudhakar, Manju
    Zoglauer, Andreas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) : 3614 - 3649
  • [25] Recent developments in GEANT4
    Allison, J.
    Amako, K.
    Apostolakis, J.
    Arce, P.
    Asai, M.
    Aso, T.
    Bagli, E.
    Bagulya, A.
    Banerjee, S.
    Barrand, G.
    Beck, B. R.
    Bogdanov, A. G.
    Brandt, D.
    Brown, J. M. C.
    Burkhardt, H.
    Canal, Ph.
    Cano-Ott, D.
    Chauvie, S.
    Cho, K.
    Cirrone, G. A. P.
    Cooperman, G.
    Cortes-Giraldo, M. A.
    Cosmo, G.
    Cuttone, G.
    Depaola, G.
    Desorgher, L.
    Dong, X.
    Dotti, A.
    Elvira, V. D.
    Folger, G.
    Francis, Z.
    Galoyan, A.
    Garnier, L.
    Gayer, M.
    Genser, K. L.
    Grichine, V. M.
    Guatelli, S.
    Gueye, P.
    Gumplinger, P.
    Howard, A. S.
    Hrivnacova, I.
    Hwang, S.
    Incerti, S.
    Ivanchenko, A.
    Ivanchenko, V. N.
    Jones, F. W.
    Jun, S. Y.
    Kaitaniemi, P.
    Karakatsanis, N.
    Karamitrosi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 835 : 186 - 225
  • [26] Geant4 atomic relaxation
    Guatelli, S
    Mantero, A
    Mascialino, B
    Nieminen, P
    Pia, MG
    Saliceti, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2178 - 2181
  • [27] Geant4 simulation of continuum
    Silva, Z.
    Ferrer, A.
    Cristancho, F.
    VII LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2007, 947 : 489 - +
  • [28] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, J
    Pokorski, W
    Ranjard, F
    Robbe, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2182 - 2185
  • [29] TRANSMISSION EFFICIENCY OF THE SAGE SPECTROMETER USING GEANT4
    Cox, D. M.
    Herzberg, R. -D.
    Papadakis, P.
    Ali, F.
    Butler, P. A.
    Cresswell, J. R.
    Mistry, A.
    Sampson, J.
    Seddon, D. A.
    Thornhill, J.
    Wells, D.
    Konki, J.
    Greenlees, P. T.
    Rahkila, P.
    Pakarinen, J.
    Sandzelius, M.
    Sorri, J.
    Julin, R.
    Coleman-Smith, P. J.
    Lazarus, I. H.
    Letts, S. C.
    Simpson, J.
    Pucknell, V. F. E.
    FISSION AND PROPERTIES OF NEUTRON-RICH NUCLEI, ICFN5, 2013, : 332 - 339
  • [30] Geant4 electromagnetic physics
    Chauvie, S
    Grichine, V
    Gumplinger, P
    Ivanchenko, V
    Kokoulin, R
    Magni, S
    Maire, M
    Nieminen, P
    Pia, MG
    Rybin, A
    Urban, L
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 153 - 158