Study of truncated cone filters using GEANT4

被引:0
|
作者
Himukai, T
Takada, Y
Kohno, R
机构
[1] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 305, Japan
[2] Natl Inst Radiol Sci, Chiba 260, Japan
关键词
D O I
10.1118/1.1998077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A ridge filter has been used for proton therapy to form a spread‐out Bragg peak (SOBP). As the SOBP width becomes larger and the distal falloff becomes smaller, more number of ridge elements is required for the ridge filter. Then extremity of the ridge filter becomes too sharp to machine for large SOBP widths. Since an aperture collimator shapes the proton beam, beam mixing by adjacent ridges is affected by scattering in the ridge elements in the peripheral region. Namely, the proximal part of the SOBP begins to fall at depth deeper than the expected depth. A purpose in this study is to achieve uniformities of both the SOBP and the lateral dose distribution by improving a conventional ridge filter. Method and Materials: We have designed a two‐dimensional array of truncated cone filters (TCF) in honeycomb structure. Since extremity of the TCF is moderate compared with a conventional ridge filter (CRF), manufacturing the TCF is relatively easy. Thus the TCF enables selection of lighter material with smaller scattering effect. In this study, a CRF (aluminum alloy) and a TCF (Lucite) with a SOBP width of 60mm were designed for a 155MeV proton beam. We simulated dose distribution in water for a therapeutic beam with GEANT4 to investigate the influence of both ridge filters. Results: While a few% dose decrease is observed in the proximal part of the SOBP region for the CRF, the dose distribution is more uniform in entire of SOBP region for the TCF. Conclusion: We designed a two‐dimensional array of TCF. It is easier to machine the TCF for SOBP filters with large SOBP widths especially for low‐energy protons. Overall dose uniformity of the SOBP region in the TCF was improved as compared with the CRF. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2030 / 2031
页数:2
相关论文
共 50 条
  • [1] A Study on Multiplex Proton Imaging Using GEANT4
    Aso, Tsukasa
    Kawashima, Kazuki
    Nishio, Teiji
    Lee, Se Byeong
    Sasaki, Takashi
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1717 - 1719
  • [2] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [3] Simulation study of Fast Neutron Radiography using GEANT4
    Bishnoi, S.
    Thomas, R. G.
    Sarkar, P. S.
    Datar, V. M.
    Sinha, A.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [4] Study of small time projection chamber using Geant4
    Garcia, F.
    Kalliokoski, M.
    Numminen, A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 839 - 842
  • [5] Study of proton computed tomography using GEANT4 simulation
    Aso, Tsukasa
    Fujisaka, Katsuhiko
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 876 - 879
  • [6] MUON TELESCOPE (MUTE): A FIRST STUDY USING GEANT4
    Asorey, H.
    Balaguera-Rojas, A.
    Calderon-Ardila, R.
    Nunez, L. A.
    Sanabria-Gomez, J. D.
    Suarez-Duran, M.
    Tapia, A.
    XV LATIN AMERICAN REGIONAL IAU MEETING, 2016, 2017, 49 : 144 - 144
  • [7] Simulation study for a single TOF scintillator using GEANT4
    Zhang, LM
    Peng, HP
    Zhang, ZP
    Chen, HF
    Shao, M
    Wu, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (07) : N54 - N57
  • [8] A Roadmap For Geant4
    Asai, Makoto
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [9] Introduction to GEANT4
    Asai, M
    2000 CERN SCHOOL OF COMPUTING, 2000, 2000 (13): : 107 - 116
  • [10] Visualization in GEANT4
    Allison, J
    HEPVIS96 WORKSHOP ON VISUALIZATION IN HIGH-ENERGY PHYSICS, 1997, 97 (01): : 61 - 65