The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study

被引:75
|
作者
Amornvit, Pokpong [1 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
关键词
digital; face scanners; accuracy; three-dimensional analysis; face analysis; facial driven design; INTRAORAL SCANNERS; FACIAL ASYMMETRY; ARCH IMPRESSIONS; RELIABILITY; TECHNOLOGY; WORKFLOW; 2D;
D O I
10.3390/ijerph16245061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Face scanners promise wide applications in medicine and dentistry, including facial recognition, capturing facial emotions, facial cosmetic planning and surgery, and maxillofacial rehabilitation. Higher accuracy improves the quality of the data recorded from the face scanner, which ultimately, will improve the outcome. Although there are various face scanners available on the market, there is no evidence of a suitable face scanner for practical applications. The aim of this in vitro study was to analyze the face scans obtained from four scanners; EinScan Pro (EP), EinScan Pro 2X Plus (EP+) (Shining 3D Tech. Co., Ltd. Hangzhou, China), iPhone X (IPX) (Apple Store, Cupertino, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA), and to compare scans obtained from various scanners with the control (measured from Vernier caliper). This should help to identify the appropriate scanner for face scanning. A master face model was created and printed from polylactic acid using the resolution of 200 microns on x, y, and z axes and designed in Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The face models were 3D scanned with four scanners, five times, according to the manufacturer's recommendations; EinScan Pro (Shining 3D Tech. Co., Ltd. Hangzhou, China), EinScan Pro 2X Plus (Shining 3D Tech. Co., Ltd. Hangzhou, China) using Shining Software, iPhone X (Apple Store, Cupertino, CA, USA) using Bellus3D Face Application (Bellus3D, version 1.6.2, Bellus3D, Inc. Campbell, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA). Scan data files were saved as stereolithography (STL) files for the measurements. From the STL files, digital face models are created in the computer using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). Various measurements were measured five times from the reference points in three axes (x, y, and z) using a digital Vernier caliper (VC) (Mitutoyo 150 mm Digital Caliper, Mitutoyo Co., Kanagawa, Japan), and the mean was calculated, which was used as the control. Measurements were measured on the digital face models of EP, EP+, IPX, and PM using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The descriptive statistics were done from SPSS version 20 (IBM Company, Chicago, USA). One-way ANOVA with post hoc using Scheffe was done to analyze the differences between the control and the scans (EP, EP+, IPX, and PM). The significance level was set at p = 0.05. EP+ showed the highest accuracy. EP showed medium accuracy and some lesser accuracy (accurate until 10 mm of length), but IPX and PM showed the least accuracy. EP+ showed accuracy in measuring the 2 mm of depth (diameter 6 mm). All other scanners (EP, IPX, and PM) showed less accuracy in measuring depth. Finally, the accuracy of an optical scan is dependent on the technology used by each scanner. It is recommended to use EP+ for face scanning.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Hole Filling in 3D Scans for Digital Anthropometric Applications
    Sobhiyeh, Sima
    Dechenaud, Marcelline
    Dunkel, Alexander
    LaBorde, Margarite
    Kennedy, Samantha
    Shepherd, John
    Heymsfield, Steven
    Wolenski, Peter
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 2752 - 2757
  • [42] Confocal 3D Optical Intraoral Scanners and Comparison of Image Capturing Accuracy
    Amornvit, Pokpong
    Rokaya, Dinesh
    Peampring, Chaimongkon
    Sanohkan, Sasiwimol
    CMC-COMPUTERS MATERIALS & CONTINUA, 2021, 66 (01): : 303 - 314
  • [43] Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment
    Grant, Caroline A.
    Johnston, Melissa
    Adam, Clayton J.
    Little, J. Paige
    MEDICAL ENGINEERING & PHYSICS, 2019, 63 : 63 - 71
  • [44] From range scans to 3D models
    Curless, B
    COMPUTER GRAPHICS-US, 1999, 33 (04): : 38 - 41
  • [45] Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons
    Renne, Walter
    Ludlow, Mark
    Fryml, John
    Schurch, Zach
    Mennito, Anthony
    Kessler, Ray
    Lauer, Abigail
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (01): : 36 - 42
  • [46] Surgical accuracy in 3D planned bimaxillary osteotomies: intraoral scans and plaster casts as digital dentition models
    Beek, D-M
    Baan, F.
    Liebregts, J.
    Berge, S.
    Maal, T.
    Xi, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 51 (07) : 922 - 928
  • [47] From Range Scans to 3D Models
    Curless, Brian
    Computer Graphics (ACM), 1999, 33 (04): : 38 - 41
  • [48] CONFOCAL MICROENDOSCOPIC 3D IMAGING USING MEMS SCANNERS FOR BOTH LATERAL AND AXIAL SCANS
    Liu, Lin
    Wang, Erkang
    Zhang, Xiaoyang
    Tang, Yiqi
    Xie, Huikai
    26TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2013), 2013, : 1085 - 1088
  • [49] Accuracy of 3D facial scans: a comparison of three different scanning system in an in vivo study
    Federica Pellitteri
    Fabrizio Scisciola
    Francesca Cremonini
    Matilde Baciliero
    Luca Lombardo
    Progress in Orthodontics, 24
  • [50] Accuracy of 3D facial scans: a comparison of three different scanning system in an in vivo study
    Pellitteri, Federica
    Scisciola, Fabrizio
    Cremonini, Francesca
    Baciliero, Matilde
    Lombardo, Luca
    PROGRESS IN ORTHODONTICS, 2023, 24 (01)