On the closing sounds of a mechanical heart valve

被引:14
|
作者
Wu, CF
Herman, BA
Retta, SM
Grossman, LW
Liu, JS
Hwang, NHC
机构
[1] Florida Atlantic Univ, Coll Engn, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[2] US FDA, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[3] Natl Hlth Res Inst, Div Med Engn Res, Miaoli, Taiwan
基金
美国国家科学基金会;
关键词
mechanical heart valves; cavitation detection; cavitation noise; impact sound;
D O I
10.1007/s10439-005-3237-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Bjork-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 50 条
  • [1] On the Closing Sounds of a Mechanical Heart Valve
    Changfu Wu
    Bruce A. Herman
    Stephen M. Retta
    Laurence W. Grossman
    Jia-Shing Liu
    Ned H. C. Hwang
    Annals of Biomedical Engineering, 2005, 33 : 743 - 750
  • [2] Spectral characteristics of mechanical heart valve closing sounds
    Johansen, P
    Lomholt, M
    Nygaard, H
    JOURNAL OF HEART VALVE DISEASE, 2002, 11 (05): : 736 - 744
  • [3] Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis
    Andrea Bagno
    Federico Anzil
    Roberto Buselli
    Elena Pesavento
    Vincenzo Tarzia
    Vittorio Pengo
    Tomaso Bottio
    Gino Gerosa
    Journal of Artificial Organs, 2009, 12 : 172 - 181
  • [4] Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis
    Bagno, Andrea
    Anzil, Federico
    Buselli, Roberto
    Pesavento, Elena
    Tarzia, Vincenzo
    Pengo, Vittorio
    Bottio, Tomaso
    Gerosa, Gino
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (03) : 172 - 181
  • [5] Application of wavelet analysis to the phonocardiographic signal of mechanical heart valve closing sounds
    Bagno, Andrea
    Anzil, Federico
    Tarzia, Vincenzo
    Pengo, Vittorio
    Ruggeri, Alfredo
    Gerosa, Gino
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (03): : 166 - 172
  • [6] PERCEPTION OF MECHANICAL HEART-VALVE SOUNDS
    THULIN, LI
    LUHRS, CH
    OLIN, CL
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 23 (03): : 259 - 261
  • [7] Classification of mechanical prosthetic heart valve sounds
    Zhang, Di
    He, Jiazhong
    Jiang, Yueping
    Du, Minghui
    INTERNATIONAL JOURNAL OF COMPUTATIONAL SCIENCE AND ENGINEERING, 2013, 8 (04) : 368 - 375
  • [8] DETECTION OF MECHANICAL CHANGES TO PROSTHETIC HEART-VALVES BY SPECTRAL-ANALYSIS OF VALVE CLOSING SOUNDS
    REYNOLDS, KJ
    STEPHEN, RO
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (01): : 60 - 68
  • [9] Closing behavior of the mechanical heart valve in a total artificial heart
    H. S. Lee
    T. Tsukiya
    A. Homma
    Y. Taenaka
    E. Tatsumi
    H. Takano
    Journal of Artificial Organs, 2003, 6 (1) : 0037 - 0041
  • [10] PROBLEMS ASSOCIATED WITH MECHANICAL HEART-VALVE SOUNDS
    LIMB, D
    KAY, PH
    MURDAY, AJ
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (11) : 618 - 620