Cavity length dependence on strain sensitivity for Fabry-Perot sensors

被引:0
|
作者
Rodrigues, Antonio V. [1 ,2 ,3 ]
Reis, Joao [1 ,2 ]
Martins, Antonio Jose M. [4 ]
Monteiro, Catarina S. [1 ,2 ,3 ]
Silva, Susana O. [2 ]
Caridade, Cristina M. R. [4 ]
Tavares, Sergio O. [5 ]
Frazao, Orlando [1 ,2 ]
机构
[1] Univ Porto, Dept Phys & Astron, Fac Sci, Rua Campo Alegre,S-N, P-4169007 Porto, Portugal
[2] Ctr Appl Photon INESC TEC, Porto, Portugal
[3] Univ Porto, Dept Engn Phys, Fac Engn, Porto, Portugal
[4] Polytech Coimbra, Inst Engn, Coimbra, Portugal
[5] Univ Aveiro, Dept Mech Engn, Ctr Mech Technol & Automat, Aveiro, Portugal
关键词
Fabry-Perot; hollow core; interferometer; optical fiber sensing; strain; temperature;
D O I
10.1002/mop.33405
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents the dependence of strain sensitivity on cavity length in conventional Fabry-Perot (F-P) sensors. A high number of F-P sensors were required and to ensure their reproducibility, a manufacturing process was developed to obtain similar sensors but with different types of lengths. A hollow-core silica tube was used to fabricate several F-P cavities by fusion splicing it between two sections of SMF28 fiber. The fabricated F-P has a varying length ranging from 15 to 2500 mu m. The cavities were measured under a microscope and the reflected spectrum was acquired for each one. Strain measurements were performed for a maximum strain of 1000 mu epsilon. The strain sensitivity showed a highly linear correlation with increment lambda(FSR). Small length variations for short cavities heavily affect the FSR value. The smallest and longest cavities present sensitivities of 8.71 and 2.68 pm/mu epsilon, respectively. Thermal characterization for low- and high-temperature regimes was also performed and is constant for tested sensors.
引用
收藏
页码:1951 / 1957
页数:7
相关论文
共 50 条
  • [21] Self-referenced composite Fabry-Perot cavity vapor sensors
    Reddy, Karthik
    Fan, Xudong
    OPTICS EXPRESS, 2012, 20 (02): : 966 - 971
  • [22] Design for manufacture of micromachined Fabry-Perot cavity-based sensors
    Kim, YM
    Neikirk, DP
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 50 (1-2) : 141 - 146
  • [23] Modeling of multi-cavity Fabry-Perot optical fiber sensors
    Wierzba, Pawel
    OPTICAL FIBERS AND THEIR APPLICATIONS 2015, 2015, 9816
  • [24] Fabry-Perot vector curvature sensor based on cavity length demodulation
    Zhu, Fuxing
    Zhang, Yundong
    Qu, Yanchen
    Su, Huaiyin
    Jiang, Weiguo
    Guo, Ying
    Qi, Kaiyue
    OPTICAL FIBER TECHNOLOGY, 2020, 60 (60)
  • [25] Fabry-Perot cavity cascaded sagnac loops for temperature and strain measurements
    Shangguan, Chunmei
    Zhang, Wen
    Hei, Wei
    Luo, Fei
    Zhu, Lianqing
    OPTICAL ENGINEERING, 2018, 57 (04)
  • [26] FABRY-PEROT WITH AN ABSORBING ETALON CAVITY
    HERNANDEZ, G
    APPLIED OPTICS, 1985, 24 (18): : 3062 - 3067
  • [27] Light squeezing in a Fabry-Perot cavity
    Gahir, HK
    Sen, G
    Sen, P
    OPTICAL AND QUANTUM ELECTRONICS, 2004, 36 (07) : 615 - 626
  • [28] Quantization of fields in a Fabry-Perot cavity
    Ezawa, H
    PHYSICS ESSAYS, 1996, 9 (04) : 604 - 608
  • [29] A Fabry-Perot cavity for Compton polarimetry
    Jorda, JP
    Burtin, E
    Cavata, C
    Jardillier, J
    Frois, B
    Neyret, D
    Martino, J
    Platchkov, S
    Pussieux, T
    Authier, M
    Deck, P
    Falletto, N
    Sellier, JC
    Veyssiere, C
    Delbart, A
    Mangeot, P
    Rebourgeard, P
    Colombel, N
    Girardot, P
    Zavattini, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (01): : 1 - 18
  • [30] Fabry-Perot cavity for Compton polarimetry
    Jorda, J.P.
    Burtin, E.
    Cavata, Ch.
    Jardillier, J.
    Frois, B.
    Neyret, D.
    Martino, J.
    Platchkov, S.
    Pussieux, T.
    Authier, M.
    Deck, P.
    Falletto, N.
    Sellier, J.C.
    Veyssiere, C.
    Delbart, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 412 (01): : 1 - 18