Fabry-Perot cavity cascaded sagnac loops for temperature and strain measurements

被引:3
|
作者
Shangguan, Chunmei [1 ,2 ,3 ]
Zhang, Wen [1 ,2 ,3 ]
Hei, Wei [1 ,2 ,3 ]
Luo, Fei [1 ,2 ,3 ]
Zhu, Lianqing [1 ,2 ,3 ]
机构
[1] Beijing Informat Sci & Technol Univ, Beijing Engn Res Ctr Optoelect Informat & Instrum, Beijing, Peoples R China
[2] Minist Educ, Key Lab Modern Measurement Control Technol, Beijing, Peoples R China
[3] Beijing Informat Sci & Technol Univ, Beijing Key Lab Optoelect Test Technol, Beijing, Peoples R China
关键词
chemical etched; Fabry-Perot cavity; sagnac loops; temperature; strain;
D O I
10.1117/1.OE.57.4.047103
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The fabrication process and temperature and strain characterizations of an all-fiber sensor are presented. The sensing structure based on a Fabry-Perot cavity (FPC) and sagnac loops was proposed and experimentally demonstrated for measurements of temperature and strain. The FPC consists of a micro-piece of chemical etched multimode fiber end face, welded with another single mode fiber. Then, the sagnac loops composed of polarization maintaining fiber was connected to the FPC. The sensor was fabricated and tested for temperature and strain. Experimental results show that sensitivity of temperature and strain is 0.71 +/- 0.03 nm/degrees C and 1.30 +/- 0.01 pm/mu epsilon, respectively; the linearity are 0.9970 and 0.9996, respectively. (C)2018society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Fabry-Perot cavity cascaded sagnac loops for temperature and strain measurements (vol 57, 047103, 2018)
    Shangguan, Chunmei
    Zhang, Wen
    He, Wei
    Luo, Fei
    Zhu, Lianqing
    OPTICAL ENGINEERING, 2018, 57 (12)
  • [2] High sensitivity temperature and pressure sensor based on cascaded Fabry-Perot and Sagnac interferometers
    Chen, Hai-lin
    Zhu, Xi-ping
    Jiang, Chao
    Li, Hong
    Guo, Xiao-shan
    Sun, Si-mei
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2022, 50 (04) : 422 - 436
  • [3] High sensitivity temperature and pressure sensor based on cascaded Fabry-Perot and Sagnac interferometers
    Chen, Hai-lin
    Zhu, Xi-ping
    Jiang, Chao
    Li, Hong
    Guo, Xiao-shan
    Sun, Si-mei
    Instrumentation Science and Technology, 2022, 50 (04): : 422 - 436
  • [4] FABRY-PEROT CAVITY FOR DIELECTRIC MEASUREMENTS
    BREEDEN, KH
    LANGLEY, JB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (09): : 1162 - &
  • [5] Intrinsic Fabry-Perot fiber sensor for temperature and strain measurements
    Huang, ZY
    Zhu, YZ
    Chen, XP
    Wang, AB
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (11) : 2403 - 2405
  • [6] Cascaded-cavity Fabry-Perot interferometer for simultaneous measurement of temperature and strain with cross-sensitivity compensation
    Tian, Jiajun
    Jiao, Yuzhu
    Ji, Shaobo
    Dong, Xiaolong
    Yao, Yong
    OPTICS COMMUNICATIONS, 2018, 412 : 121 - 126
  • [7] Cascaded Fabry-Perot cavity and fiber Bragg grating on sapphire fibers for high-temperature strain sensing
    Shen, Yafeng
    Jiang, Yi
    Xie, Shangran
    Sui, Guanghui
    Zhang, Xinying
    OPTICS AND LASERS IN ENGINEERING, 2025, 184
  • [8] Time resolved Fabry-Perot measurements of cavity temperature in pulsed QCLs
    Gundogdu, S.
    Pisheh, H. S.
    Demir, A.
    Gunoven, M.
    Aydinli, A.
    Sirtori, C.
    OPTICS EXPRESS, 2018, 26 (06): : 6572 - 6580
  • [9] Multiparameter Sensing of the Vernier Effect Based on Cascaded Sagnac and Fabry-Perot Interferometers
    Cheng, Ao
    Wang, Chaoqi
    Xu, Jiadong
    Dai, Shixun
    Zheng, Yu
    IEEE SENSORS JOURNAL, 2024, 24 (12) : 19090 - 19097
  • [10] Dislocated Fabry-Perot fiber cavity for strain measurement
    Liu, Jing
    Liu, Ye
    Wang, D. N.
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,