Scattered radiation from applicators in clinical electron beams

被引:25
|
作者
van Battum, LJ
van der Zee, W
Huizenga, H
机构
[1] Dr Daniel Den Hoed Canc Ctr, Dept Radiotherapy, Subdiv Clin Phys, Erasmus MC, NL-3008 AE Rotterdam, Netherlands
[2] Reiner De Graaf Grp, NL-2600 GA Delft, Netherlands
[3] Catholic Univ Nijmegen, Ctr Med, NL-6500 HB Nijmegen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 15期
关键词
D O I
10.1088/0031-9155/48/15/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. Inmost currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight change of the intensity of the primary beam. The scattered radiation from an applicator changes with the field size and distance from the applicator. The amount of scattered radiation is dependent on the applicator design and on the formation of the electron beam in the treatment head. Electron applicators currently applied in most treatment machines are essentially a set of diaphragms, but still do produce scattered radiation. This paper investigates the present level of scattered dose from electron applicators, and as such provides an extensive set of measured data. The data provided could for instance serve as example input data or benchmark data for advanced treatment planning algorithms which employ a parametrized initial phase space to characterize the clinical electron beam. Central axis depth dose curves of the electron beams have been measured with and without applicators in place, for various applicator sizes and energies, for a Siemens Primus, a Varian 2300 C/D and an Elekta SLi accelerator. Scattered radiation generated by the applicator has been found by subtraction of the central axis depth dose curves, obtained with and without applicator. Scattered radiation from Siemens, Varian and Elekta electron applicators is still significant and cannot be neglected in advanced treatment planning. Scattered radiation at the surface of a water phantom can be as high as 12%. Scattered radiation decreases almost linearly with depth. Scattered radiation from Varian applicators shows clear dependence on beam energy. The Elekta applicators produce less scattered radiation than those of Varian and Siemens, but feature a higher effective angular variance. The scattered radiation decreases somewhat with increasing field size and is spread uniformly over the aperture. Experimental results comply with the results of simulations of the treatment head and electron applicator, using the BEAM Monte Carlo code.
引用
收藏
页码:2493 / 2507
页数:15
相关论文
共 50 条
  • [1] Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams
    Jabbari, Nasrollah
    Hashemi-Malayeri, Bijan
    Farajollahi, Ali Reza
    Kazemnejad, Anoshiravan
    NUKLEONIKA, 2007, 52 (03) : 97 - 103
  • [2] LEAKAGE RADIATION FROM ELECTRON APPLICATORS ON A MEDICAL ACCELERATOR
    PENNINGTON, EC
    JANI, SK
    WEN, BC
    MEDICAL PHYSICS, 1988, 15 (05) : 763 - 765
  • [3] Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators
    Di Venanzio, Cristina
    Marinelli, Marco
    Tonnetti, Alessia
    Verona-Rinati, Gianluca
    Bagala, Paolo
    Falco, Maria Daniela
    Guerra, Antonio Stefano
    Pimpinella, Maria
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 329 - 335
  • [4] Peripheral dose outside applicators in electron beams
    Chow, James C. L.
    Grigorov, Grigor N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12): : N231 - N240
  • [5] Radiation leakage and scatter from electron applicators in modern accelerators
    Lazarescu, G
    Das, I
    Fallon, K
    Xiao, Y
    Zhu, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1798 - 1799
  • [6] Radiation qualities of electron beams in clinical trials
    Nevelsky, A
    Glicksman, A
    Bar-Deroma, R
    Tatcher, M
    Kuten, A
    Pawtucket, RI
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S112 - S112
  • [7] SOME MEASUREMENTS OF SCATTERED RADIATION FROM ROENTGEN DIAGNOSTIC BEAMS
    FLATBY, J
    MAUDAL, S
    ACTA RADIOLOGICA, 1956, 46 (05) : 690 - 699
  • [8] The absorption of the scattered electron beams.
    Recknagel, A.
    ZEITSCHRIFT FUR PHYSIK, 1935, 94 (5-6): : 356 - 360
  • [9] RADIATION LEAKAGE ASSESSMENT OF INTRAOPERATIVE ELECTRON APPLICATORS
    BAGNE, F
    SAMSAMI, N
    MEDICAL PHYSICS, 1987, 14 (03) : 484 - 484
  • [10] MICROWAVE RADIATION FROM RELATIVISTIC ELECTRON BEAMS
    NATION, JA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1572 - &