Scattered radiation from applicators in clinical electron beams

被引:25
|
作者
van Battum, LJ
van der Zee, W
Huizenga, H
机构
[1] Dr Daniel Den Hoed Canc Ctr, Dept Radiotherapy, Subdiv Clin Phys, Erasmus MC, NL-3008 AE Rotterdam, Netherlands
[2] Reiner De Graaf Grp, NL-2600 GA Delft, Netherlands
[3] Catholic Univ Nijmegen, Ctr Med, NL-6500 HB Nijmegen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 15期
关键词
D O I
10.1088/0031-9155/48/15/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. Inmost currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight change of the intensity of the primary beam. The scattered radiation from an applicator changes with the field size and distance from the applicator. The amount of scattered radiation is dependent on the applicator design and on the formation of the electron beam in the treatment head. Electron applicators currently applied in most treatment machines are essentially a set of diaphragms, but still do produce scattered radiation. This paper investigates the present level of scattered dose from electron applicators, and as such provides an extensive set of measured data. The data provided could for instance serve as example input data or benchmark data for advanced treatment planning algorithms which employ a parametrized initial phase space to characterize the clinical electron beam. Central axis depth dose curves of the electron beams have been measured with and without applicators in place, for various applicator sizes and energies, for a Siemens Primus, a Varian 2300 C/D and an Elekta SLi accelerator. Scattered radiation generated by the applicator has been found by subtraction of the central axis depth dose curves, obtained with and without applicator. Scattered radiation from Siemens, Varian and Elekta electron applicators is still significant and cannot be neglected in advanced treatment planning. Scattered radiation at the surface of a water phantom can be as high as 12%. Scattered radiation decreases almost linearly with depth. Scattered radiation from Varian applicators shows clear dependence on beam energy. The Elekta applicators produce less scattered radiation than those of Varian and Siemens, but feature a higher effective angular variance. The scattered radiation decreases somewhat with increasing field size and is spread uniformly over the aperture. Experimental results comply with the results of simulations of the treatment head and electron applicator, using the BEAM Monte Carlo code.
引用
收藏
页码:2493 / 2507
页数:15
相关论文
共 50 条
  • [31] FREQUENCY OF SCATTERED RADIATION BY RELATIVISTIC ELECTRON BEAM
    CHAN, YW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 506 - &
  • [32] Monte Carlo simulation and measurement of radiation leakage from applicators used in external electron radiotherapy
    Shimozato, Tomohiro
    Okudaira, Kuniyasu
    Fuse, Hiraku
    Tabushi, Katsuyoshi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 388 - 396
  • [33] Betatron radiation from electron beams in plasma focusing channels
    Esarey, E
    Catravas, P
    Leemans, WP
    ADVANCED ACCELERATOR CONCEPTS, 2001, 569 : 473 - 486
  • [34] Coherent spontaneous radiation from highly bunched electron beams
    Berryman, KW
    Crosson, ER
    Ricci, KN
    Smith, TI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 375 (1-3): : 526 - 529
  • [35] Enhanced coherent undulator radiation from bunched electron beams
    Berryman, KW
    Crosson, ER
    Ricci, KN
    Smith, TI
    MICRO BUNCHES WORKSHOP, 1996, (367): : 357 - 366
  • [36] The Radiation from Curvilinear Electron Beams in Periodical Magnetic Fields
    B. P. Yefimov
    International Journal of Infrared and Millimeter Waves, 2000, 21 : 21 - 30
  • [37] The radiation from curvilinear electron beams in periodical magnetic fields
    Yefimov, BP
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 21 (01): : 21 - 30
  • [38] RADIATION FROM PULSED ELECTRON-BEAMS IN SPACE PLASMAS
    HARKER, KJ
    BANKS, PM
    RADIO SCIENCE, 1984, 19 (02) : 454 - 470
  • [39] Stimulated radiation from spatiotemporally gyrating relativistic electron beams
    Davies, JA
    Chen, C
    PHYSICS OF PLASMAS, 2000, 7 (10) : 4291 - 4302
  • [40] Towards Evaluating the Biological Impact of Increased Scattered Radiation in Highly Modulated Radiation Beams
    Nusrat, H.
    Pang, G.
    Medrek, A.
    Ahmad, S.
    Keller, B.
    Sarfehnia, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2885 - 2885