Essential system response information for transient-based leak detection methods

被引:47
|
作者
Duan, Huan-Feng [1 ]
Lee, Pedro J. [2 ]
Ghidaoui, Mohamed S. [1 ]
Tung, Yeou-Koung [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
[2] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch 1, New Zealand
关键词
Inverse transient analysis; leak detection; pipe system; system response function; transient damping; transient reflection; PIPELINES;
D O I
10.1080/00221686.2010.507014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many transient-based techniques have been developed for leak detection in piping fluid systems, and they are thought to use leak-induced damping and reflection effects to detect and locate the problem. This work investigates the relative importance of the damping and reflective effects from the leak to the leak detection methods with the importance of both effects tested using four representative methods, which vary significantly in their modes of operation and provide the coverage of the major developments in the transient leak detection field. It was found that all transient-based methods are unable to detect and locate the leak in the absence of the leak-reflected signal, whereas the leak is detected and located even in the absence of leak-induced damping. The results indicate that the information previously thought to be contained in the damping of slow transients was found to be low frequency reflections from the leak.
引用
收藏
页码:650 / 657
页数:8
相关论文
共 50 条
  • [31] Multiple-fault detection in water pipelines using transient-based time-frequency analysis
    Sun, Jilong
    Wang, Ronghe
    Duan, Huan-Feng
    JOURNAL OF HYDROINFORMATICS, 2016, 18 (06) : 975 - 989
  • [32] Incorporation of prior information on parameters in inverse transient analysis for leak detection and roughness calibration
    Kapelan, Z.
    Savic, D. A.
    Walters, G. A.
    URBAN WATER JOURNAL, 2004, 1 (02) : 129 - 143
  • [33] Transient test-based technique for leak detection in outfall pipes
    Department of Hydr., Dept. of Water and Struct. Engrg., Univ. of Perugia, via G. Duranti 93, 06125 Perugia, Italy
    J. Water Resour. Plann. Manage., 5 (302-306):
  • [34] Transient test-based technique for leak detection in outfall pipes
    Brunone, B
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1999, 125 (05): : 302 - 306
  • [35] Sensitivity Analysis of a Transient-Based Frequency Domain Method for Extended Blockage Detection in Water Pipeline Systems
    Duan, H. F.
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2016, 142 (04)
  • [36] Study on Personal Information Leak Detection Based on Machine Learning
    Lee, Sangdo
    Woo, Hanchul
    Shin, Yongtae
    ADVANCED SCIENCE LETTERS, 2017, 23 (12) : 12818 - 12821
  • [37] Leak Detection in a Branched System by Inverse Transient Analysis with the Admittance Matrix Method
    Capponi, Caterina
    Ferrante, Marco
    Zecchin, Aaron C.
    Gong, Jinzhe
    WATER RESOURCES MANAGEMENT, 2017, 31 (13) : 4075 - 4089
  • [38] Leak Detection in a Branched System by Inverse Transient Analysis with the Admittance Matrix Method
    Caterina Capponi
    Marco Ferrante
    Aaron C. Zecchin
    Jinzhe Gong
    Water Resources Management, 2017, 31 : 4075 - 4089
  • [39] The Gas Leak Detection Based on a Wireless Monitoring System
    Dong, Linxi
    Qiao, Zhiyuan
    Wang, Haonan
    Yang, Weihuang
    Zhao, Wensheng
    Xu, Kuiwen
    Wang, Gaofeng
    Zhao, Libo
    Yan, Haixia
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (12) : 6240 - 6251
  • [40] Development of Pipeline Leak Detection System based on LabVIEW
    Hu Qiong
    Fan Shidong
    2008 IEEE INTERNATIONAL SYMPOSIUM ON KNOWLEDGE ACQUISITION AND MODELING WORKSHOP PROCEEDINGS, VOLS 1 AND 2, 2008, : 671 - 674