Transient test-based technique for leak detection in outfall pipes

被引:223
|
作者
Brunone, B [1 ]
机构
[1] Univ Perugia, Dept Water & Struct Engn, I-06125 Perugia, Italy
关键词
D O I
10.1061/(ASCE)0733-9496(1999)125:5(302)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A technique is proposed for leak detection and evaluation in outfall pipes based on properties of transient pressure waves. Transients are caused by an increase of the piezometric head at the initial section of the outfall pipe. Since high overpressures are not necessary for the success of the technique and simple equipment is required, tests may be repeated periodically to check the state of the pipe. In order to verify the possibility of locating a possible leak on the basis of the results of transient tests, the effects of a leak on wave propagation from the numerical point of view are discussed first. A first-order formula for preliminary evaluation of the discharge behavior of the leak is also given. Results of some laboratory tests carried out on a long pipe are shown in order to confirm the reliability and validity of the proposed technique. Inverse transient calculations are proved to be able to provide precise information about the characteristics of the leak.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 50 条
  • [1] Transient test-based technique for leak detection in outfall pipes
    Department of Hydr., Dept. of Water and Struct. Engrg., Univ. of Perugia, via G. Duranti 93, 06125 Perugia, Italy
    J. Water Resour. Plann. Manage., 5 (302-306):
  • [2] Backward transient analysis: A conceptual method for leak detection in pressurized pipes
    Haghighi, A.
    Covas, D.
    Ramos, H.
    ENVIRONMENTAL HYDRAULICS: THEORETICAL, EXPERIMENTAL AND COMPUTATIONAL SOLUTIONS, 2010, : 333 - +
  • [3] Effectiveness assessment of pipe systems by means of transient test-based techniques
    Brunone, B.
    Ferrante, M.
    Meniconi, S.
    Massari, C.
    FOUR DECADES OF PROGRESS IN MONITORING AND MODELING OF PROCESSES IN THE SOIL-PLANT-ATMOSPHERE SYSTEM: APPLICATIONS AND CHALLENGES, 2013, 19 : 814 - 822
  • [4] Coherenceogram for leak detection in water pipes
    Zeng, Wei
    Cazzolato, Benjamin
    Lambert, Martin
    Stephens, Mark
    Gong, Jinzhe
    JOURNAL OF SOUND AND VIBRATION, 2022, 530
  • [5] Block Averaging Based Leak Detection for Water Pipes Based On Vibration Sensors
    Kim, Kibeom
    Oh, Heeseok
    Choi, Jihoon
    2019 34TH INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS AND COMMUNICATIONS (ITC-CSCC 2019), 2019, : 432 - 434
  • [6] Experimental Investigation of Coupled Frequency and Time-Domain Transient Test-Based Techniques for Partial Blockage Detection in Pipelines
    Meniconi, S.
    Duan, H. F.
    Lee, P. J.
    Brunone, B.
    Ghidaoui, M. S.
    Ferrante, M.
    JOURNAL OF HYDRAULIC ENGINEERING, 2013, 139 (10) : 1033 - 1040
  • [7] Test-Based Educational Accountability
    Koretz, Daniel
    ZEITSCHRIFT FUR PADAGOGIK, 2008, 54 (06): : 777 - 790
  • [8] Leak detection in pipes by frequency response method
    Mpesha, W
    Gassman, SL
    Chaudhry, MH
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2001, 127 (02): : 134 - 147
  • [9] Signal Detection for Medical Scientists: Likelihood Ratio Based Test-Based Methodology
    Chaturvedi, Anoop
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES A-STATISTICS IN SOCIETY, 2022, 185 (02) : 725 - 726
  • [10] FRF-based transient wave analysis for the viscoelastic parameters identification and leak detection in water-filled plastic pipes
    Pan, Bin
    Duan, Huan-Feng
    Meniconi, Silvia
    Brunone, Bruno
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 146