Comparative Study of In Situ Techniques to Enlarge Gold Nanoparticles for Highly Sensitive Lateral Flow Immunoassay of SARS-CoV-2

被引:19
|
作者
Panferov, Vasily G. [1 ]
Byzova, Nadezhda A. [1 ]
Biketov, Sergey F. [2 ]
Zherdev, Anatoly, V [1 ]
Dzantiev, Boris B. [1 ]
机构
[1] Russian Acad Sci, AN Bach Inst Biochem, Res Ctr Biotechnol, Moscow 119071, Russia
[2] State Res Ctr Appl Microbiol & Biotechnol, Obolensk 142279, Moscow Region, Russia
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 07期
关键词
immunochromatography; point-of-care testing; limit of detection; antigen test; coronavirus; receptor-binding domain; silver enhancement; gold enhancement; galvanic replacement; spike protein; AU NANOPARTICLES; SILVER; ENHANCEMENT; ASSAYS;
D O I
10.3390/bios11070229
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three techniques were compared for lowering the limit of detection (LOD) of the lateral flow immunoassay (LFIA) of the receptor-binding domain of severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) based on the post-assay in situ enlargement of Au nanoparticles (Au NPs) on a test strip. Silver enhancement (growth of a silver layer over Au NPs-Au@Ag NPs) and gold enhancement (growth of a gold layer over Au NPs) techniques and the novel technique of galvanic replacement of Ag by Au in Au@Ag NPs causing the formation of Au@Ag-Au NPs were performed. All the enhancements were performed on-site after completion of the conventional LFIA and maintained equipment-free assay. The assays demonstrated lowering of LODs in the following rows: 488 pg/mL (conventional LFIA with Au NPs), 61 pg/mL (silver enhancement), 8 pg/mL (galvanic replacement), and 1 pg/mL (gold enhancement). Using gold enhancement as the optimal technique, the maximal dilution of inactivated SARS-CoV-2-containing samples increased 500 times. The developed LFIA provided highly sensitive and rapid (8 min) point-of-need testing.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Evaluation of SARS-CoV-2 total antibody detection via a lateral flow nanoparticle fluorescence immunoassay
    Sibai, Mamdouh
    Solis, Daniel
    Roltgen, Katharina
    Stevens, Bryan A.
    Mfuh, Kenji O.
    Sahoo, Malaya K.
    Shi, Run Z.
    Zehnder, James
    Boyd, Scott D.
    Pinsky, Benjamin A.
    JOURNAL OF CLINICAL VIROLOGY, 2021, 139
  • [32] Development of a Lateral Flow Strip Membrane Assay for Rapid and Sensitive Detection of the SARS-CoV-2
    Yu, Sangheon
    Nimse, Satish Balasaheb
    Kim, Junghoon
    Song, Keum-Soo
    Kim, Taisun
    ANALYTICAL CHEMISTRY, 2020, 92 (20) : 14139 - 14144
  • [33] Interpreting a lateral flow SARS-CoV-2 antigen test
    Mytton, Oliver T.
    McCarthy, Noel
    Watson, Jessica
    Whiting, Penny
    BMJ-BRITISH MEDICAL JOURNAL, 2021, 373
  • [34] Development of a highly specific and sensitive VHH-based sandwich immunoassay for the detection of the SARS-CoV-2 nucleoprotein
    Gransagne, Marion
    Ayme, Gabriel
    Brier, Sebastien
    Chauveau-Le Friec, Gaelle
    Meriaux, Veronique
    Nowakowski, Mireille
    Dejardin, Francois
    Levallois, Sylvain
    de Melo, Guilherme Dias
    Donati, Flora
    Prot, Matthieu
    Brule, Sebastien
    Raynal, Bertrand
    Bellalou, Jacques
    Goncalves, Pedro
    Montagutelli, Xavier
    Di Santo, James P.
    Lazarini, Francoise
    England, Patrick
    Petres, Stephane
    Escriou, Nicolas
    Lafaye, Pierre
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2022, 298 (01)
  • [35] Nanobody-Based Lateral Flow Immunoassay for Rapid Antigen Detection of SARS-CoV-2 and MERS-CoV Proteins
    Peng, Yuli
    Huang, Yaning
    Kiessling, Fabian
    Renn, Dominik
    Rueping, Magnus
    ACS SYNTHETIC BIOLOGY, 2025, 14 (02): : 420 - 430
  • [36] Quantitative and ultrasensitive in situ immunoassay technology for SARS-CoV-2 detection in saliva
    Chen, Yuchao
    Liu, Fei
    Lee, Luke P.
    SCIENCE ADVANCES, 2022, 8 (21)
  • [37] Development of a lateral flow immunoassay strip for rapid detection of IgG antibody against SARS-CoV-2 virus
    Wen, Tian
    Huang, Chao
    Shi, Feng-Juan
    Zeng, Xiao-Yan
    Lu, Tian
    Ding, Shou-Nian
    Jiao, Yong-Jun
    ANALYST, 2020, 145 (15) : 5345 - 5352
  • [38] Analytical performance of lateral flow immunoassay for SARS-CoV-2 exposure screening on venous and capillary blood samples
    Black, Margaret A.
    Shen, Guomiao
    Feng, Xiaojun
    Beltran, Wilfredo F. Garcia
    Feng, Yang
    Vasudevaraja, Varshini
    Allison, Douglas
    Lin, Lawrence H.
    Gindin, Tatyana
    Astudillo, Michael
    Yang, Diane
    Murali, Mandakolathur
    Iafrate, A. John
    Jour, George
    Cotzia, Paolo
    Snuderl, Matija
    JOURNAL OF IMMUNOLOGICAL METHODS, 2021, 489
  • [39] Comparison of a Prototype SARS-CoV-2 Lateral Flow IMMUNOASSAY with the BinaxNOW™ COVID-19 Antigen CARD
    Hill, Haydon J.
    Uppal, Timsy
    Hau, Derrick
    Pandit, Sujata G.
    Arias-Umana, Jose
    Foster, Abigail J.
    Gorzalski, Andrew
    Pflughoeft, Kathryn J.
    Burnham-Marusich, Amanda R.
    Reed, Dana E.
    Gates-Hollingsworth, Marcellene A.
    Gumbleton, Lynette
    Verma, Subhash C.
    AuCoin, David P.
    VIRUSES-BASEL, 2022, 14 (12):
  • [40] A Lateral Flow Immunoassay Coupled with a Spectrum-Based Reader for SARS-CoV-2 Neutralizing Antibody Detection
    Huang, Rui-Lin
    Fu, Yi-Chen
    Wang, Yung-Chih
    Hong, Chitsung
    Yang, Wei-Chieh
    Wang, I-Jen
    Sun, Jun-Ren
    Chen, Yunching
    Shen, Ching-Fen
    Cheng, Chao-Min
    VACCINES, 2022, 10 (02)