Comparative Study of In Situ Techniques to Enlarge Gold Nanoparticles for Highly Sensitive Lateral Flow Immunoassay of SARS-CoV-2

被引:19
|
作者
Panferov, Vasily G. [1 ]
Byzova, Nadezhda A. [1 ]
Biketov, Sergey F. [2 ]
Zherdev, Anatoly, V [1 ]
Dzantiev, Boris B. [1 ]
机构
[1] Russian Acad Sci, AN Bach Inst Biochem, Res Ctr Biotechnol, Moscow 119071, Russia
[2] State Res Ctr Appl Microbiol & Biotechnol, Obolensk 142279, Moscow Region, Russia
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 07期
关键词
immunochromatography; point-of-care testing; limit of detection; antigen test; coronavirus; receptor-binding domain; silver enhancement; gold enhancement; galvanic replacement; spike protein; AU NANOPARTICLES; SILVER; ENHANCEMENT; ASSAYS;
D O I
10.3390/bios11070229
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three techniques were compared for lowering the limit of detection (LOD) of the lateral flow immunoassay (LFIA) of the receptor-binding domain of severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) based on the post-assay in situ enlargement of Au nanoparticles (Au NPs) on a test strip. Silver enhancement (growth of a silver layer over Au NPs-Au@Ag NPs) and gold enhancement (growth of a gold layer over Au NPs) techniques and the novel technique of galvanic replacement of Ag by Au in Au@Ag NPs causing the formation of Au@Ag-Au NPs were performed. All the enhancements were performed on-site after completion of the conventional LFIA and maintained equipment-free assay. The assays demonstrated lowering of LODs in the following rows: 488 pg/mL (conventional LFIA with Au NPs), 61 pg/mL (silver enhancement), 8 pg/mL (galvanic replacement), and 1 pg/mL (gold enhancement). Using gold enhancement as the optimal technique, the maximal dilution of inactivated SARS-CoV-2-containing samples increased 500 times. The developed LFIA provided highly sensitive and rapid (8 min) point-of-need testing.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A lateral flow immunoassay test performance in SARS-CoV-2 seroprevalence surveys: a validation study among healthcare workers
    Garlantezec, Ronan
    Heslan, Christopher
    Tadie, Emilie
    Tattevin, Pierre
    Thibault, Vincent
    Paris, Christophe
    EMERGING MICROBES & INFECTIONS, 2020, 9 (01) : 2547 - 2549
  • [22] Development of a quantum dot-based lateral flow immunoassay strip for rapid and sensitive detection of SARS-CoV-2 neutralizing antibodies
    Wang, Xirong
    Shao, Shulin
    Ye, Huan
    Li, Sen
    Gu, Bing
    Tang, Bo
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [23] Development of a quantum dot-based lateral flow immunoassay strip for rapid and sensitive detection of SARS-CoV-2 neutralizing antibodies
    Xirong Wang
    Shulin Shao
    Huan Ye
    Sen Li
    Bing Gu
    Bo Tang
    Scientific Reports, 13 (1)
  • [24] A rapid lateral flow immunoassay strip for detection of SARS-CoV-2 antigen using latex microspheres
    Shen, Lin
    Zhang, Qihan
    Luo, Xiaolu
    Xiao, Haolin
    Gu, Miao
    Cao, Liangli
    Zhao, Feijun
    Chen, Zhencheng
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (12)
  • [25] Challenges in the Detection of SARS-CoV-2: Evolution of the Lateral Flow Immunoassay as a Valuable Tool for Viral Diagnosis
    Shantal Castrejon-Jimenez, Nayeli
    Estela Garcia-Perez, Blanca
    Edith Reyes-Rodriguez, Nydia
    Vega-Sanchez, Vicente
    Manuel Martinez-Juarez, Victor
    Carlos Hernandez-Gonzalez, Juan
    BIOSENSORS-BASEL, 2022, 12 (09):
  • [26] Highly Sensitive and Quantitative Diagnosis of SARS-CoV-2 Using a Gold/Platinum Particle-Based Lateral Flow Assay and a Desktop Scanning Electron Microscope
    Kawasaki, Hideya
    Suzuki, Hiromi
    Furuhashi, Kazuki
    Yamashita, Keita
    Ishikawa, Jinko
    Nagura, Osanori
    Maekawa, Masato
    Miwa, Takafumi
    Tandou, Takumi
    Hariyama, Takahiko
    BIOMEDICINES, 2022, 10 (02)
  • [27] Comparison of Three Lateral Flow Immunoassay Formats for the Detection of Antibodies against the SARS-CoV-2 Antigen
    Sotnikov, Dmitriy V.
    Byzova, Nadezhda A.
    Zherdev, Anatoly V.
    Xu, Youchun
    Dzantiev, Boris B.
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [28] Next-Generation Rapid and Ultrasensitive Lateral Flow Immunoassay for Detection of SARS-CoV-2 Variants
    Lin, Chenglong
    Liu, Zhenzhen
    Fang, Fanghao
    Zhao, Shuai
    Li, Yanyan
    Xu, Meimei
    Peng, Yusi
    Chen, Hongyou
    Yuan, Fang
    Zhang, Wanju
    Zhang, Xi
    Teng, Zheng
    Xiao, Rui
    Yang, Yong
    ACS SENSORS, 2023, 8 (10) : 3733 - 3743
  • [29] Evaluation of a Lateral Flow Immunoassay COVIDTECH® SARS-CoV-2 IgM/IgG Antibody Rapid Test
    Exinger, Julien
    Hartard, Cedric
    Lafferriere, Fanny
    Fenninger, Christelle
    Charbonniere, Loic J.
    Jeulin, Helene
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2022, 75 (04) : 334 - 340
  • [30] Pushing the Limits of Lateral Flow Immunoassay by Digital SERS for the Ultralow Detection of SARS-CoV-2 Virus
    Gonzalez-Cabaleiro, Lara
    Fernandez-Lodeiro, Carlos
    Vazquez-Iglesias, Lorena
    Soriano-Maldonado, Pablo
    van Raaij, Mark J.
    Bodelon, Gustavo
    Perez-Juste, Jorge
    Pastoriza-Santos, Isabel
    SMALL SCIENCE, 2024, 4 (11):