Peak area, peak current: Critical comparison. Application to real samples

被引:0
|
作者
Locatelli, C [1 ]
Torsi, G [1 ]
机构
[1] Univ Bologna, Dept Chem G Ciamician, I-40126 Bologna, Italy
关键词
peak area; stripping analysis; data processing;
D O I
10.1002/(SICI)1521-4109(199810)10:13<904::AID-ELAN904>3.0.CO;2-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of using peak area as instrumental datum for determining the concentration of metal species in solution (instead of peak height) is proposed for analytical voltammetric determinations. In this work a comparison is made between peak area and peak current in voltammetric metal determinations. The metals considered are copper(II), lead(II), cadmium(II) and zinc(II) in seawater. The influence of the instrumental parameters (pulse amplitude, electrodeposition time, stirring rate, potential scan rate, drop size, delay before sweep) on the data is studied, in order to optimize the analytical procedure. The precision and accuracy of the analytical method was tested on the reference material Sea Water BCR-CRM 403. The precision, expressed as relative standard deviation (s(r)), and the accuracy, expressed as relative error (e), were, in all cases of the order of 3 to 5%, while the detection limit was around 10(-3) mu g L-1 for all the metals.
引用
收藏
页码:904 / 907
页数:4
相关论文
共 50 条
  • [41] Design Comparison of Peak Current Mode Switching Power Converter for DC Distribution Systems
    Kajiwara, Kazuhiro
    Koga, Yasuyuki
    Hattori, Shinichiro
    Matsui, Nobumasa
    Kurokawa, Fujio
    2019 8TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA 2019), 2019, : 1038 - 1041
  • [42] Sharp peak of the critical current density in BaFe2-xNixAs2 at optimal composition
    Van Gennep, Derrick
    Hassan, Abdelwahab
    Luo, Huiqian
    Abdel-Hafiez, Mahmoud
    PHYSICAL REVIEW B, 2020, 101 (23)
  • [43] THEORY OF THE THERMALLY-STIMULATED-CURRENT TRANSPORT PEAK - APPLICATION TO A DISPERSIVE TRANSPORT CASE
    PLANS, J
    ZIELINSKI, M
    KRYSZEWSKI, M
    PHYSICAL REVIEW B, 1981, 23 (12): : 6557 - 6569
  • [44] Second peak and critical current for YBa1.9Na0.1Cu3Oy
    Leng, X
    Luo, H
    Qiu, L
    Liu, Y
    Wang, ZH
    Ding, SY
    Zhang, H
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2003, 386 : 245 - 248
  • [45] Network Robustness Index Application at Pikes Peak Area Council of Governments, Colorado Springs, Colorado
    Lupa, Mary R.
    Prather, Ken
    de Araujo, Maureen Paz
    Casper, Craig
    TRANSPORTATION RESEARCH RECORD, 2015, (2499) : 10 - 17
  • [46] Application of TELUM by the Pikes Peak, Colorado, Area Council of Governments Lessons Learned in Colorado Springs
    Casper, Craig T.
    O'Brien, Jason
    Lupa, Mary R.
    Dimitrijevic, Branislav
    de Araujo, Maureen Paz
    TRANSPORTATION RESEARCH RECORD, 2009, (2119) : 45 - 53
  • [47] Comparison of Peak Inspiratory Flow Rate Between Clinical Trial and Real-World Populations
    Mularski, R. A.
    Drummond, M. B.
    Jain, R.
    Corbridge, T. C.
    Moretz, C.
    Zhu, C. Q.
    Collison, K.
    Hamilton, M.
    Prime, D.
    Martin, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [48] Development and Application of Peak Shaving Real-time Supervision System of Thermal Power Units
    Zhao Qingchuan
    Su Jianjun
    Wang Yong
    Zhao Yan
    Yang Minghui
    Wang Lei
    Li Wendong
    Wang Shouen
    Liu Ke
    Zhang Xuhui
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 1739 - 1744
  • [49] Investigation of the active surface area of tool electrode and peak current on discharge energy during the ECDM process
    Rathore, Ranjeet Singh
    Dvivedi, Akshay
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2022, 29 (04) : 459 - 464
  • [50] Comparison of Lightning Peak Current Estimation Between Triggered Lightning Striking the Overhead Line and the Ground
    Cai L.
    Hu Q.
    Peng X.
    Chen S.
    Zhou M.
    Wang J.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (06): : 2589 - 2597