Peak area, peak current: Critical comparison. Application to real samples

被引:0
|
作者
Locatelli, C [1 ]
Torsi, G [1 ]
机构
[1] Univ Bologna, Dept Chem G Ciamician, I-40126 Bologna, Italy
关键词
peak area; stripping analysis; data processing;
D O I
10.1002/(SICI)1521-4109(199810)10:13<904::AID-ELAN904>3.0.CO;2-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of using peak area as instrumental datum for determining the concentration of metal species in solution (instead of peak height) is proposed for analytical voltammetric determinations. In this work a comparison is made between peak area and peak current in voltammetric metal determinations. The metals considered are copper(II), lead(II), cadmium(II) and zinc(II) in seawater. The influence of the instrumental parameters (pulse amplitude, electrodeposition time, stirring rate, potential scan rate, drop size, delay before sweep) on the data is studied, in order to optimize the analytical procedure. The precision and accuracy of the analytical method was tested on the reference material Sea Water BCR-CRM 403. The precision, expressed as relative standard deviation (s(r)), and the accuracy, expressed as relative error (e), were, in all cases of the order of 3 to 5%, while the detection limit was around 10(-3) mu g L-1 for all the metals.
引用
收藏
页码:904 / 907
页数:4
相关论文
共 50 条
  • [21] A Peak Dilation Angle Model Considering the Real Contact Area for Rock Joints
    Liren Ban
    Weisheng Du
    Chengzhi Qi
    Rock Mechanics and Rock Engineering, 2020, 53 : 4909 - 4923
  • [22] Elastic properties of the Abrikosov lattice near the upper critical field and peak effect in the critical current
    Rosenstein, B.
    Zhuravlev, V.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (04): : 362 - 367
  • [23] MICROWAVE PEAK POWER MEASUREMENT INDEPENDENT OF DETECTOR CHARACTERISTICS BY COMPARISON OF VIDEO SAMPLES
    WEINERT, FK
    WEINSCHEL, BO
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1972, IM21 (04) : 474 - +
  • [24] Comparison of transient performance in a peak current-mode flyback converter
    Dallago, E
    Danioni, A
    Passoni, M
    Venchi, G
    ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 1049 - 1052
  • [25] Application of a double interaction model to the backscattering peak observed for polydisperse particulate samples
    de la Peña, JL
    Saiz, JM
    González, F
    Valle, PJ
    Moreno, F
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 658 - 659
  • [26] Effect of peak current mode control on transient response for VRM application
    Abe, Seiya
    Ninomiya, Tamotsu
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1647 - +
  • [27] Peak effect of critical current in a Bi-2212 superconducting single crystal
    Matsushita, T
    Hirano, T
    Yamato, H
    Kiuchi, M
    Nakayama, Y
    Shimoyama, J
    Kishio, K
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1998, 11 (10): : 925 - 928
  • [28] Comparison of the Capability of Peak Function in Describing Real Condensation Particle Counter Profiles
    Djebara, Abdelhakim
    Khettabi, Riad
    Kouam, Jules
    Songmene, Victor
    LASER AND PLASMA APPLICATIONS IN MATERIALS SCIENCE, 2011, 227 : 96 - 100
  • [29] Improving the reproducibility in capillary electrophoresis by incorporating current drift in mobility and peak area calculations
    Petersen, Nickolaj J.
    Hansen, Steen H.
    ELECTROPHORESIS, 2012, 33 (06) : 1021 - 1031
  • [30] Average and Peak Current Mode Control Comparison for Full-Bridge Converter
    Caliskan, Alihan Cemal
    Kocaaga, Ertugrul
    Kasnakoglu, Cosku
    2021 8TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ICEEE 2021), 2021, : 202 - 206