In vitro study of a modified sagittal split osteotomy fixation technique of the mandible: a mechanical test

被引:3
|
作者
Sonego, C. L. [1 ]
Scheffer, M. A. R. [1 ]
Chagas Junior, O. L. [2 ]
Vetromilla, B. M. [3 ]
Fernandes, L. P. [1 ]
Ozkomur, A. [1 ]
Silva Junior, A. N. [1 ]
Miguens Junior, S. A. Q. [1 ]
Hernandez, P. A. G. [1 ]
机构
[1] Univ Luterana Brasil, Grad Program Dent Oral & Maxillofacial Surg, Canoas, RS, Brazil
[2] Univ Fed Pelotas, Univ Hosp, Oral & Maxillofacial Surg Residency Program, Pelotas, RS, Brazil
[3] Univ Fed Pelotas, Grad Program Dent Prosthodont, Sch Dent, Pelotas, RS, Brazil
关键词
sagittal split osteotomy of the mandibular ramus; fracture fixation; material resistance; RIGID INTERNAL-FIXATION; RAMUS OSTEOTOMY; BIOMECHANICAL EVALUATION; PLATE FIXATION; ORTHOGNATHIC SURGERY; ADVANCEMENT SURGERY; SCREW FIXATION; STABILITY; SETBACK; MINIPLATE;
D O I
10.1016/j.ijom.2018.03.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study was performed to evaluate the compressive mechanical strength of rigid internal fixation (RIF) using 1.5-mm L-shaped plates fixed with monocortical screws in sagittal split osteotomy (SSO). Thirty synthetic hemimandibles, which had all undergone a 5-mm advancement, were divided into three groups: three 12-mm bicortical titanium screws were placed in an inverted L pattern in group A; one straight 2.0-mm system spaced titanium plate fixed with four 5-mm monocortical screws was used in group B; two 1.5-mm system L-shaped titanium plates, each fixed with four 5-mm monocortical screws, were used in group C. The models were subjected to compressive and progressive mechanical tests with forces applied in the area between the second premolar and first molar to verify resistance in Newtons (N). A displacement speed of 1 mm/min was applied, with a maximum 10 mm displacement of the distal segment or until disruption of the fixation. The deformity and/or eventual rupture of the plates were evaluated, and consequently their technical stability was determined. The results showed that the modified fixation technique tested in this study on synthetic mandibles resulted in adequate stability and superior mechanical behaviour compared to simulated osteosynthesis with the use of a straight 2.0-mm titanium plate.
引用
收藏
页码:1330 / 1335
页数:6
相关论文
共 50 条
  • [41] A modified surgical technique of parallel sagittal split osteotomy of the ramus (parallel method)
    Sasaki, K
    Noma, H
    Takaki, T
    Tamura, H
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (11) : 1366 - 1368
  • [42] Bad split during bilateral sagittal split osteotomy of the mandible with separators: a retrospective study of 427 patients
    Mensink, Gertjan
    Verweij, Jop P.
    Frank, Michael D.
    Bergsma, J. Eelco
    van Merkesteyn, J. P. Richard
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (06): : 525 - 529
  • [44] An in vitro comparison of the mechanical characteristics of three sagittal ramus osteotomy fixation techniques
    Murphy, MT
    Haug, RH
    Barber, JE
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (05) : 489 - 494
  • [45] Stability of fixation methods in large mandibular advancements after sagittal split ramus osteotomy: an in vitro biomechanical study
    Kuik, K.
    Ho, J. P. T. F.
    de Ruiter, M. H. T.
    Klop, C.
    Kleverlaan, C. J.
    de Lange, J.
    Hoekema, A.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2021, 59 (04): : 466 - 471
  • [47] Mandibular remodeling after bilateral sagittal split osteotomy for prognathism of the mandible
    Huang, CS
    de Villa, GH
    Lion, EJW
    Chen, YR
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (02) : 167 - 172
  • [48] Sagittal Split Osteotomy on the Previously Reconstructed Mandible With Fibula Free Flap
    Kim, Jin-Wook
    Lee, Cheong-Hee
    Kwon, Tae-Geon
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (05) : 1833 - 1835
  • [49] Patient perception of neurosensory deficit after sagittal split osteotomy in the mandible
    Bothur, S
    Blomqvist, JE
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (01) : 373 - 377
  • [50] Concomitant Third Molar Removal During Sagittal Split Osteotomy of the Mandible
    Sasaki, Ryo
    Yao, Chuan-Fong
    Chen, Ying-an
    Lin, Cheng-Hui
    Chen, Yu-Ray
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (01) : E34 - E36