Measurements of wound edge microvascular blood flow during negative pressure wound therapy using thermodiffusion and transcutaneous and invasive laser Doppler velocimetry

被引:46
|
作者
Borgquist, Ola [1 ,2 ,3 ]
Anesater, Erik [2 ,3 ]
Hedstrom, Erik [3 ,4 ]
Lee, Charles K. [5 ]
Ingemansson, Richard [3 ,6 ]
Malmsjo, Malin [2 ,3 ]
机构
[1] Lund Univ, Dept Anesthesiol & Intens Care, Lund, Sweden
[2] Lund Univ, Dept Ophthalmol, Lund, Sweden
[3] Skane Univ Hosp, Lund, Sweden
[4] Lund Univ, Dept Clin Physiol, Lund, Sweden
[5] Univ Calif San Francisco, Div Plast & Reconstruct Surg, San Francisco, CA 94143 USA
[6] Lund Univ, Dept Cardiothorac Surg, Lund, Sweden
基金
英国医学研究理事会;
关键词
VACUUM-ASSISTED CLOSURE; MICROCIRCULATION; VALIDATION; GAUZE; FOAM;
D O I
10.1111/j.1524-475X.2011.00741.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The effects of negative pressure wound therapy (NPWT) on wound edge microvascular blood flow are not clear. The aim of the present study was therefore to further elucidate the effects of NPWT on periwound blood flow in a porcine peripheral wound model using different blood flow measurement techniques. NPWT at -20, -40, -80, and -125 mmHg was applied to a peripheral porcine wound (n = 8). Thermodiffusion, transcutaneous, and invasive laser Doppler velocimetry were used to measure the blood perfusion 0.5, 1.0, and 2.5 cm from the wound edge. Thermodiffusion (an invasive measurement technique) generally showed a decrease in perfusion close to the wound edge (0.5 cm), and an increase further from the edge (2.5 cm). Invasive laser Doppler velocimetry showed a similar response pattern, with a decrease in blood flow 0.5 cm from the wound edge and an increase further away. However, 1.0 cm from the wound edge blood flow decreased with high pressure levels and increased with low pressure levels. A different response pattern was seen with transcutaneous laser Doppler velocimetry, showing an increase in blood flow regardless of the distance from the wound edge (0.5, 1.0, and 2.5 cm). During NPWT, both increases and decreases in blood flow can be seen in the periwound tissue depending on the distance from the wound edge and the pressure level. The pattern of response depends partly on the measurement technique used. The combination of hypoperfusion and hyperperfusion caused by NPWT may accelerate wound healing.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 47 条
  • [31] Effective management of continuous salivary flow through a pharyngocutaneous fistula using a negative pressure wound therapy device
    Maeda, Taku
    Tsushima, Nayuta
    Ishikawa, Kosuke
    Yamamoto, Yuhei
    JPRAS OPEN, 2025, 43 : 74 - 78
  • [32] Microvascular blood flow in scalds in children and its relation to duration of wound healing: A study using laser speckle contrast imaging
    Mirdell, Robin
    Iredahl, Fredrik
    Sjoberg, Folke
    Farnebo, Simon
    Tesselaar, Erik
    BURNS, 2016, 42 (03) : 648 - 654
  • [33] Analysis of blood flow and local expression of angiogenesis-associated growth factors in infected wounds treated with negative pressure wound therapy
    Xia, Cheng-Yan
    Yu, Ai-Xi
    Qi, Baiwen
    Zhou, Min
    Li, Zong-Huan
    Wang, Wei-Yang
    MOLECULAR MEDICINE REPORTS, 2014, 9 (05) : 1749 - 1754
  • [34] Pressure transduction and fluid evacuation during conventional negative pressure wound therapy of the open abdomen and NPWT using a protective disc over the intestines
    Lindstedt, Sandra
    Malmsjo, Malin
    Hansson, Johan
    Hlebowicz, Joanna
    Ingemansson, Richard
    BMC SURGERY, 2012, 12
  • [35] Pressure transduction and fluid evacuation during conventional negative pressure wound therapy of the open abdomen and NPWT using a protective disc over the intestines
    Sandra Lindstedt
    Malin Malmsjö
    Johan Hansson
    Joanna Hlebowicz
    Richard Ingemansson
    BMC Surgery, 12
  • [36] Measurement of blood flow velocity in a model of stenosis in vitro and in mesenteric vessels in vivo using non-invasive micro multipoint laser Doppler velocimetry
    Akiguchi, Shunsuke
    Ishida, Hiroki
    Andoh, Tsugunobu
    Hachiga, Tadashi
    Shimizu, Tadamichi
    Kuraishi, Yasushi
    Shirakawa, Hiroki
    Ueyama, Koji
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (04)
  • [37] Effects on drainage of the mediastinum and pleura during negative pressure wound therapy when using a rigid barrier to prevent heart rupture
    Lindstedt, Sandra
    Malmsjo, Malin
    Ingemansson, Richard
    INTERNATIONAL WOUND JOURNAL, 2011, 8 (05) : 454 - 458
  • [38] Non-invasive assessment of negative pressure wound therapy using high frequency diagnostic ultrasound: oedema reduction and new tissue accumulation
    Young, Stephen R.
    Hampton, Sylvie
    Martin, Robin
    INTERNATIONAL WOUND JOURNAL, 2013, 10 (04) : 383 - 388
  • [39] DYNAMICS OF CHANGES IN BRAIN-STEM BLOOD-FLOW DURING HYPERCAPNIA AND ASPHYXIA USING LASER DOPPLER (LD) VELOCIMETRY IN THE NEWBORN PIGLET
    NORTHINGTON, F
    PINTO, L
    DARNALL, R
    PEDIATRIC RESEARCH, 1989, 25 (04) : A359 - A359
  • [40] Topical negative pressure therapy of a sternotomy wound increases sternal fluid content but does not affect internal thoracic artery blood flow:: Assessment using magnetic resonance imaging
    Petzina, Rainer
    Ugander, Martin
    Gustafsson, Lotta
    Engblom, Henrik
    Hetzer, Roland
    Arheden, Hakan
    Ingemansson, Richard
    Malmsjo, Malin