Measurements of wound edge microvascular blood flow during negative pressure wound therapy using thermodiffusion and transcutaneous and invasive laser Doppler velocimetry

被引:46
|
作者
Borgquist, Ola [1 ,2 ,3 ]
Anesater, Erik [2 ,3 ]
Hedstrom, Erik [3 ,4 ]
Lee, Charles K. [5 ]
Ingemansson, Richard [3 ,6 ]
Malmsjo, Malin [2 ,3 ]
机构
[1] Lund Univ, Dept Anesthesiol & Intens Care, Lund, Sweden
[2] Lund Univ, Dept Ophthalmol, Lund, Sweden
[3] Skane Univ Hosp, Lund, Sweden
[4] Lund Univ, Dept Clin Physiol, Lund, Sweden
[5] Univ Calif San Francisco, Div Plast & Reconstruct Surg, San Francisco, CA 94143 USA
[6] Lund Univ, Dept Cardiothorac Surg, Lund, Sweden
基金
英国医学研究理事会;
关键词
VACUUM-ASSISTED CLOSURE; MICROCIRCULATION; VALIDATION; GAUZE; FOAM;
D O I
10.1111/j.1524-475X.2011.00741.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The effects of negative pressure wound therapy (NPWT) on wound edge microvascular blood flow are not clear. The aim of the present study was therefore to further elucidate the effects of NPWT on periwound blood flow in a porcine peripheral wound model using different blood flow measurement techniques. NPWT at -20, -40, -80, and -125 mmHg was applied to a peripheral porcine wound (n = 8). Thermodiffusion, transcutaneous, and invasive laser Doppler velocimetry were used to measure the blood perfusion 0.5, 1.0, and 2.5 cm from the wound edge. Thermodiffusion (an invasive measurement technique) generally showed a decrease in perfusion close to the wound edge (0.5 cm), and an increase further from the edge (2.5 cm). Invasive laser Doppler velocimetry showed a similar response pattern, with a decrease in blood flow 0.5 cm from the wound edge and an increase further away. However, 1.0 cm from the wound edge blood flow decreased with high pressure levels and increased with low pressure levels. A different response pattern was seen with transcutaneous laser Doppler velocimetry, showing an increase in blood flow regardless of the distance from the wound edge (0.5, 1.0, and 2.5 cm). During NPWT, both increases and decreases in blood flow can be seen in the periwound tissue depending on the distance from the wound edge and the pressure level. The pattern of response depends partly on the measurement technique used. The combination of hypoperfusion and hyperperfusion caused by NPWT may accelerate wound healing.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 47 条
  • [21] MEASUREMENTS OF BLOOD-FLOW IN HUMAN RETINAL BLOOD-VESSELS USING LASER DOPPLER VELOCIMETRY
    TANAKA, T
    ROSS, B
    BENSIRA, I
    RIVA, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 480 - 480
  • [22] Macroscopic changes during negative pressure wound therapy of the open abdomen using conventional negative pressure wound therapy and NPWT with a protective disc over the intestines
    Sandra Lindstedt
    Malin Malmsjö
    Johan Hansson
    Joanna Hlebowicz
    Richard Ingemansson
    BMC Surgery, 11
  • [23] Macroscopic changes during negative pressure wound therapy of the open abdomen using conventional negative pressure wound therapy and NPWT with a protective disc over the intestines
    Lindstedt, Sandra
    Malmsjo, Malin
    Hansson, Johan
    Hlebowicz, Joanna
    Ingemansson, Richard
    BMC SURGERY, 2011, 11
  • [24] A Rigid Disc for Protection of Exposed Blood Vessels During Negative Pressure Wound Therapy
    Anesater, Erik
    Borgquist, Ola
    Torbrand, Christian
    Roupe, K. Markus
    Ingemansson, Richard
    Lindstedt, Sandra
    Malmsjo, Malin
    SURGICAL INNOVATION, 2013, 20 (01) : 74 - 80
  • [25] New microvascular blood flow research challenges practice protocols in negative pressure wound therapy (vol 17, pg 290, 2005)
    Miller, MS
    WOUNDS-A COMPENDIUM OF CLINICAL RESEARCH AND PRACTICE, 2005, 17 (12): : A4 - A4
  • [26] Blood flow response in small intestinal loops at different depths during negative pressure wound therapy of the open abdomen
    Lindstedt, Sandra
    Hlebowicz, Joanna
    INTERNATIONAL WOUND JOURNAL, 2013, 10 (04) : 411 - 417
  • [27] Microvascular blood flow in the deep brain structures - Laser doppler measurements during DBS-implantations
    Wardell, K.
    Hemm-Ode, S.
    Rejmstad, P.
    Richter, J.
    Zsigmond, P.
    MOVEMENT DISORDERS, 2014, 29 : S467 - S467
  • [28] LASER DOPPLER FLOWMETRY IN EVALUATION OF CUTANEOUS WOUND BLOOD-FLOW USING VARIOUS SUTURING TECHNIQUES
    ZOGRAFOS, GC
    MARTIS, K
    MORRIS, DL
    ANNALS OF SURGERY, 1992, 215 (03) : 266 - 268
  • [29] Sternum wound contraction and distension during negative pressure wound therapy when using a rigid disc to prevent heart and lung rupture
    Sandra Lindstedt
    Richard Ingemansson
    Malin Malmsjö
    Journal of Cardiothoracic Surgery, 6
  • [30] Sternum wound contraction and distension during negative pressure wound therapy when using a rigid disc to prevent heart and lung rupture
    Lindstedt, Sandra
    Ingemansson, Richard
    Malmsjo, Malin
    JOURNAL OF CARDIOTHORACIC SURGERY, 2011, 6