Comparison of Three-Dimensional Proximal Isovelocity Surface Area to Cardiac Magnetic Resonance Imaging for Quantifying Mitral Regurgitation

被引:24
|
作者
Brugger, Nicolas [1 ]
Wustmann, Kerstin [1 ]
Huerzeler, Michael [1 ]
Wahl, Andreas [1 ]
de Marchi, Stefano F. [1 ]
Steck, Helene [1 ]
Zuercher, Fabian [1 ]
Seiler, Christian [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2015年 / 115卷 / 08期
关键词
COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE; IN-VITRO; QUANTIFICATION; VALIDATION; RECOMMENDATIONS;
D O I
10.1016/j.amjcard.2015.01.550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to evaluate 3-dimensional (3D) color Doppler proximal isovelocity surface area (PISA) as a tool for quantitative assessment of mitral regurgitation (MR) against in vitro and in vivo reference methods. A customized 3D PISA software was validated in vitro against a flowmeter MR phantom. Sixty consecutive patients, with >= mild MR of any cause, were recruited and the regurgitant volume (RVol) was measured by 2D PISA, 3D peak PISA, and 3D integrated PISA, using transthoracic (TTE) and transesophageal echocardiography (TEE). Cardiac magnetic resonance imaging (CMR) was used as reference method. Flowmeter RVol was associated with 3D integrated PISA as follows: y = 0.64x + 4.7, r(2) = 0.97, p < 0.0001 for TEE and y = 0.88x + 4.07, r(2) = 0.96, p < 0.0001 for TTE. The bias and limit of agreement in the Bland-Altman analysis were 6.8 ml [-3.5 to 17.1] for TEE and -0.059 ml [-6.2 to 6.1] for TTE. In vivo, TEE-derived 3D integrated PISA was the most accurate method for MR quantification compared to CMR: r(2) = 0.76, y = 0.95x - 3.95, p < 0.0001; 5.1 ml (-14.7 to 26.5). It was superior to TEE 3D peak PISA (r(2) = 0.67, y = 1.00x + 6.20, p < 0.0001; -6.3 ml [-33.4 to 21.0]), TEE 2D PISA (r(2) = 0.54,y = 0.76x + 0.18, p < 0.0001; 8.4 ml [-20.4 to 37.2]), and TTE-derived measurements. It was also most accurate by receiver operating characteristic analysis (area under the curve 0.99) for the detection of severe MR, RVol cutoff = 48 ml, sensibility 100%, and specificity 96%. RVol and the cutoff to define severe MR were underestimated using the most accurate method. In conclusion, quantitative 3D color Doppler echocardiography of the PISA permits a more accurate MR assessment than conventional techniques and, consequently, should enable an optimized management of patients suffering from MR. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [41] Comparison of three-dimensional echo and proximal flow convergence method for quantification of mitral regurgitation
    Breburda, CS
    Griffin, BP
    Pu, M
    Scalia, GM
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7305 - 7305
  • [42] A SIMPLIFIED PROXIMAL ISOVELOCITY SURFACE-AREA APPROACH FOR ESTIMATING SEVERITY OF MITRAL REGURGITATION - MEASUREMENT OF PISA RADIUS VERSUS ISOVELOCITY
    YAMACHIKA, S
    REID, CL
    GARDIN, JM
    CIRCULATION, 1993, 88 (04) : 109 - 109
  • [43] Geometric determinants of chronic functional ischemic mitral regurgitation: Insights from three-dimensional cardiac magnetic resonance imaging - Meeting discussion
    不详
    JOURNAL OF HEART VALVE DISEASE, 2008, 17 (01): : 23 - 23
  • [44] Clinical value of parameters derived by the application of the proximal isovelocity surface area method in the assessment of mitral regurgitation
    Palau, VM
    Salvador, A
    De Arellano, AR
    Cebolla, R
    Algarra, F
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 68 (02) : 209 - 216
  • [45] Quantification of mitral valve regurgitation in dogs with degenerative mitral valve disease by use of the proximal isovelocity surface area method
    Gouni, Vassiliki
    Serres, Francois J.
    Pouchelon, Jean-Louis
    Tissier, Renaud
    Lefebvre, Herve R.
    Nicolle, Audrey P.
    Sampedrano, Carolina Carlos
    Chetboul, Valerie
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2007, 231 (03): : 399 - 406
  • [46] In vitro Assessment of Proximal Isovelocity Surface Area (PISA) Method on Double Orifice Mitral Regurgitation: Implication for Mitral Clipping
    Lee, Jeesoo
    El Hangouche, Nadia
    Van Assche, Lowie M.
    O'Brien, Ellie
    Barker, Alexander J.
    Markl, Michael
    Thomas, James D.
    CIRCULATION, 2019, 140
  • [47] Real-Time Three-Dimensional Echocardiographic Assessment of Severity of Mitral Regurgitation Using Proximal Isovelocity Surface Area and Vena Contracta Area Method. Lessons We Learned and Clinical Implications
    Buck T.
    Plicht B.
    Current Cardiovascular Imaging Reports, 2015, 8 (10)
  • [48] Quantification of Multiple Mitral Regurgitant Jets: An In Vitro Validation Study Comparing Two- and Three-Dimensional Proximal Isovelocity Surface Area Methods
    Zurcher, Fabian
    Brugger, Nicolas
    Jahren, Silje Ekroll
    de Marchi, Stefano Fausto
    Seiler, Christian
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (05) : 511 - 521
  • [49] Left ventricular sphericity: comparison of three-dimensional echocardiography and cardiac magnetic resonance imaging
    Patel, A. A.
    Onuora, A. A.
    Toole, R. S.
    Goldman, M.
    Alexander, D.
    Gupta, D.
    Kadiyala, M.
    Cao, J.
    Reichek, N.
    Gopal, A. S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 883 - 883
  • [50] Three-dimensional echocardiography of the athlete’s heart: a comparison with cardiac magnetic resonance imaging
    Ruben De Bosscher
    Mathias Claeys
    Christophe Dausin
    Kaatje Goetschalckx
    Piet Claus
    Lieven Herbots
    Olivier Ghekiere
    Caroline Van De Heyning
    Bernard P. Paelinck
    Kristel Janssens
    Leah Wright
    Michael Darragh Flannery
    André La Gerche
    Rik Willems
    Hein Heidbuchel
    Jan Bogaert
    Guido Claessen
    The International Journal of Cardiovascular Imaging, 2023, 39 : 295 - 306