Comparison of Three-Dimensional Proximal Isovelocity Surface Area to Cardiac Magnetic Resonance Imaging for Quantifying Mitral Regurgitation

被引:24
|
作者
Brugger, Nicolas [1 ]
Wustmann, Kerstin [1 ]
Huerzeler, Michael [1 ]
Wahl, Andreas [1 ]
de Marchi, Stefano F. [1 ]
Steck, Helene [1 ]
Zuercher, Fabian [1 ]
Seiler, Christian [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2015年 / 115卷 / 08期
关键词
COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE; IN-VITRO; QUANTIFICATION; VALIDATION; RECOMMENDATIONS;
D O I
10.1016/j.amjcard.2015.01.550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to evaluate 3-dimensional (3D) color Doppler proximal isovelocity surface area (PISA) as a tool for quantitative assessment of mitral regurgitation (MR) against in vitro and in vivo reference methods. A customized 3D PISA software was validated in vitro against a flowmeter MR phantom. Sixty consecutive patients, with >= mild MR of any cause, were recruited and the regurgitant volume (RVol) was measured by 2D PISA, 3D peak PISA, and 3D integrated PISA, using transthoracic (TTE) and transesophageal echocardiography (TEE). Cardiac magnetic resonance imaging (CMR) was used as reference method. Flowmeter RVol was associated with 3D integrated PISA as follows: y = 0.64x + 4.7, r(2) = 0.97, p < 0.0001 for TEE and y = 0.88x + 4.07, r(2) = 0.96, p < 0.0001 for TTE. The bias and limit of agreement in the Bland-Altman analysis were 6.8 ml [-3.5 to 17.1] for TEE and -0.059 ml [-6.2 to 6.1] for TTE. In vivo, TEE-derived 3D integrated PISA was the most accurate method for MR quantification compared to CMR: r(2) = 0.76, y = 0.95x - 3.95, p < 0.0001; 5.1 ml (-14.7 to 26.5). It was superior to TEE 3D peak PISA (r(2) = 0.67, y = 1.00x + 6.20, p < 0.0001; -6.3 ml [-33.4 to 21.0]), TEE 2D PISA (r(2) = 0.54,y = 0.76x + 0.18, p < 0.0001; 8.4 ml [-20.4 to 37.2]), and TTE-derived measurements. It was also most accurate by receiver operating characteristic analysis (area under the curve 0.99) for the detection of severe MR, RVol cutoff = 48 ml, sensibility 100%, and specificity 96%. RVol and the cutoff to define severe MR were underestimated using the most accurate method. In conclusion, quantitative 3D color Doppler echocardiography of the PISA permits a more accurate MR assessment than conventional techniques and, consequently, should enable an optimized management of patients suffering from MR. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [31] CON: Proximal isovelocity surface area should not be measured routinely in all patients with mitral regurgitation
    Savage, Robert M.
    Konstadt, Steven
    ANESTHESIA AND ANALGESIA, 2007, 105 (04): : 944 - 946
  • [32] Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: A core review
    Lambert, A. Stephane
    ANESTHESIA AND ANALGESIA, 2007, 105 (04): : 940 - 943
  • [33] QUANTIFICATION OF MITRAL REGURGITATION BY COLOR-FLOW DOPPLER IMAGING - VALUE OF THE PROXIMAL ISOVELOCITY SURFACE-AREA METHOD
    GROSSMANN, G
    GIESLER, M
    SCHMIDT, A
    KOCHS, M
    WIESHAMMER, S
    EGGELING, T
    FELDER, C
    HOMBACH, V
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1993, 42 (02) : 165 - 173
  • [34] Comparison of eccentric mitral regurgitant volumes using traditional proximal isovelocity surface area method and multiple radii proximal isovelocity surface area method
    Chaliki, H
    Moreno, C
    Appleton, C
    CIRCULATION, 2001, 104 (17) : 676 - 676
  • [35] Annular remodeling in patients with chronic ischemic mitral regurgitation: Three-dimensional magnetic resonance imaging study
    Kaji, S
    Yamamoto, A
    Kinoshita, M
    CIRCULATION, 2004, 110 (17) : 589 - 589
  • [36] Annular geometry in patients with chronic ischemic mitral regurgitation - Three-dimensional magnetic resonance imaging study
    Kaji, S
    Nasu, M
    Yamamuro, A
    Tanabe, K
    Nagai, K
    Tani, T
    Tamita, K
    Shiratori, K
    Kinoshita, M
    Senda, M
    Okada, Y
    Morioka, S
    CIRCULATION, 2005, 112 (09) : I409 - I414
  • [37] Leaning Too Much on the Power of Proximal Isovelocity Surface Area? Don't Forget the Volumetric Method for Quantifying Functional Mitral Regurgitation
    Hu, Ray
    Chen, Tiffany
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (11):
  • [38] Quantifying Mitral Regurgitation: Added Value of Three-Dimensional Echocardiography
    Little S.H.
    Current Cardiovascular Imaging Reports, 2011, 4 (5) : 361 - 369
  • [39] Reproducibility of Proximal Isovelocity Surface Area, Vena Contracta, and Regurgitant Jet Area for Assessment of Mitral Regurgitation Severity
    Biner, Simon
    Rafique, Asim
    Rafii, Farhad
    Tolstrup, Kirsten
    Noorani, Omid
    Shiota, Takahiro
    Gurudevan, Swaminatha
    Siegel, Robert J.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) : 235 - 243
  • [40] The Value of Dynamic Three-Dimensional Proximal Isovelocity Surface Area: Preventing Unnecessary Mitral Valve Replacement in a High-Risk Patient
    Gosling, Andre
    Lyvers, Jeffrey
    Warner, Kenneth
    Cobey, Frederick C.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (02) : 566 - 572