Low radiation dose in computed tomography: the role of iodine

被引:50
|
作者
Aschoff, Andrik J. [1 ]
Catalano, Carlo [2 ]
Kirchin, Miles A. [3 ]
Krix, Martin [4 ]
Albrecht, Thomas [5 ]
机构
[1] Klinikum Kempten, Dept Diagnost & Intervent Radiol & Neuroradiol, Kempten, Germany
[2] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
[3] Bracco Imaging SpA, Global Med & Regulatory Affairs, Milan, Italy
[4] Bracco Imaging Germany, Global Med & Regulatory Affairs, Constance, Germany
[5] Vivantes Klinikum Neukolln, Inst Radiol & Intervent Therapie, Berlin, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2017年 / 90卷 / 1076期
关键词
LOW-TUBE-VOLTAGE; CONCENTRATION CONTRAST-MEDIUM; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; AFFIRMED ITERATIVE RECONSTRUCTION; MEDICAL IMAGING PROCEDURES; PULMONARY ANGIOGRAPHY; IONIZING-RADIATION; DELIVERY RATE; CHEST CT;
D O I
10.1259/bjr.20170079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Variation in computed tomography radiation dose in community hospitals
    Calvert, Catherine
    Strauss, Keith J.
    Mooney, David P.
    JOURNAL OF PEDIATRIC SURGERY, 2012, 47 (06) : 1167 - 1169
  • [42] Trauma computed tomography and radiation dose: A matter of concern
    Baker, Stephen
    CRITICAL CARE MEDICINE, 2009, 37 (04) : 1508 - 1509
  • [43] Radiation Dose at Cardiac Computed Tomography Facts and Fiction
    Huda, Walter
    Rowlett, W. Taylor
    Schoepf, U. Joseph
    JOURNAL OF THORACIC IMAGING, 2010, 25 (03) : 204 - 212
  • [44] Optimizing Radiation Dose in Computed Tomography of Articular Fractures
    Mansfield, Colin
    Ali, Sayed
    Komperda, Kazimierz
    Zhao, Huaqing
    Rehman, Saqib
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (08) : 401 - 406
  • [45] Radiation Dose from Diagnostic Computed Tomography in Saskatchewan
    Leswick, David A.
    Syed, Nida S.
    Dumaine, Chance S.
    Lim, Hyun J.
    Fladeland, Derek A.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2009, 60 (02): : 71 - 78
  • [46] Computed Tomography Radiation Dose in Patients With Suspected Urolithiasis
    Smith-Bindman, Rebecca
    Moghadassi, Michelle
    Griffey, Richard T.
    Camargo, Carlos A., Jr.
    Bailitz, John
    Beland, Michael
    Miglioretti, Diana L.
    JAMA INTERNAL MEDICINE, 2015, 175 (08) : 1413 - 1416
  • [47] The reliability of radiation dose display of a computed tomography scanner
    Fross, V.
    Yli-Ollila, H.
    Vatanen, J.
    Kohli, P.
    Poutanen, V. P.
    Palomaki, A.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [48] Radiation exposure in spiral computed tomography -: Dose distribution and dose reduction
    Hidajat, N
    Mäurer, J
    Schröder, RJ
    Wolf, M
    Vogl, T
    Felix, R
    INVESTIGATIVE RADIOLOGY, 1999, 34 (01) : 51 - 57
  • [49] Achieving Very-Low-Dose Radiation Exposure in Cardiac Computed Tomography, Single-Photon Emission Computed Tomography, and Positron Emission Tomography
    Dey, Damini
    Slomka, Piotr J.
    Berman, Daniel S.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (04) : 723 - 734
  • [50] Impact of Low-Dose Computed Tomography on Computed Tomography Orders and Scan Length
    Simmons, Curtis
    Milburn, James
    OCHSNER JOURNAL, 2019, 19 (04): : 303 - 308