Low radiation dose in computed tomography: the role of iodine

被引:50
|
作者
Aschoff, Andrik J. [1 ]
Catalano, Carlo [2 ]
Kirchin, Miles A. [3 ]
Krix, Martin [4 ]
Albrecht, Thomas [5 ]
机构
[1] Klinikum Kempten, Dept Diagnost & Intervent Radiol & Neuroradiol, Kempten, Germany
[2] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
[3] Bracco Imaging SpA, Global Med & Regulatory Affairs, Milan, Italy
[4] Bracco Imaging Germany, Global Med & Regulatory Affairs, Constance, Germany
[5] Vivantes Klinikum Neukolln, Inst Radiol & Intervent Therapie, Berlin, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2017年 / 90卷 / 1076期
关键词
LOW-TUBE-VOLTAGE; CONCENTRATION CONTRAST-MEDIUM; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; AFFIRMED ITERATIVE RECONSTRUCTION; MEDICAL IMAGING PROCEDURES; PULMONARY ANGIOGRAPHY; IONIZING-RADIATION; DELIVERY RATE; CHEST CT;
D O I
10.1259/bjr.20170079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography RESPONSE
    Alkadhi, Hatem
    von Ballmoos, Moritz Wyler
    ANNALS OF INTERNAL MEDICINE, 2011, 155 (04) : 278 - +
  • [32] Low-dose computed tomography of the paranasal sinuses: radiation doses and reliability analysis
    Abul-Kasim, Kasim
    Strombeck, Anita
    Sahlstrand-Johnson, Pernilla
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2011, 32 (01) : 47 - 51
  • [33] A Feasibility Study to Evaluate Replacing Conventional Computed Tomography at 120 KVP with Low Radiation Dose and Low Iodine Intake Based on Body Mass Index-Adapted Abdominal Computed Tomography Angiography in 291 Patients
    Fang, Xin
    Liu, Yijun
    Zhang, Zijing
    Wei, Wei
    Wang, Xu
    Li, Beibei
    Tong, Xiaoyu
    MEDICAL SCIENCE MONITOR, 2023, 29 : e939228
  • [34] Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations
    Schmidt, Bernhard T.
    Hupfer, Martin
    Saltybaeva, Natalia
    Kolditz, Daniel
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (02) : 81 - 86
  • [35] The Expanding Role of Radiation Dose Index Monitoring Systems in Computed Tomography Protocol Optimization
    O'Connell, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3104 - 3104
  • [36] Radiation Dose in Abdominal Computed Tomography: The Role of Patient Size and the Selection of Tube Current
    Aldrich, John E.
    Chang, Silvia D.
    Bilawich, Ana-Marie
    Mayo, John R.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2006, 57 (03): : 152 - 158
  • [37] LOW-DOSE COMPUTED-TOMOGRAPHY
    GHOLKAR, A
    HART, CW
    MOTT, D
    GILLESPIE, JE
    ISHERWOOD, I
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 773 - 773
  • [38] The effect of trauma backboards on computed tomography radiation dose
    Lee, A. Y.
    Elojeimy, S.
    Kanal, K. M.
    Linnau, K. F.
    Gunn, M. L.
    CLINICAL RADIOLOGY, 2016, 71 (05) : 499.e1 - 499.e8
  • [39] Glandular dose in breast computed tomography with synchrotron radiation
    Mettivier, G.
    Fedon, C.
    Di Lillo, F.
    Longo, R.
    Sarno, A.
    Tromba, G.
    Russo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 569 - 587
  • [40] MAXIMUM UTILIZATION OF RADIATION-DOSE IN COMPUTED TOMOGRAPHY
    JUDY, PF
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 251 - 251