Liquid chromatography-tandem mass spectrometric assay with a novel method of quantitation for the simultaneous determination of bulaquine and its metabolite, primaquine, in monkey plasma

被引:20
|
作者
Nitin, M
Rajanikanth, M
Lal, J
Madhusudanan, KP
Gupta, RC [1 ]
机构
[1] Cent Drug Res Inst, Pharmacokinet & Metab Div, Lucknow 226001, Uttar Pradesh, India
[2] Cent Drug Res Inst, Reg Sophisticated Instrumentat Ctr, Lucknow 226001, Uttar Pradesh, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 793卷 / 02期
关键词
bulaquine; primaquine;
D O I
10.1016/S1570-0232(03)00322-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective liquid chromatography-tandemmass spectrometry method (LC-MS-MS) for the simultaneous estimation of bulaquine and primaquine has been developed and validated in monkey plasma. The mobile phase consisted of acetonitrile/ammonium acetate buffer (20 mM, pH 6) (50:50 v/v) at a flow-rate of 1 ml/min. The chromatographic separations were achieved on two spheri cyano columns (5 mum, 30X4.6 mm I.D.) connected in series. The quantitation was carried out using a Micromass LC-MS-MS with an electrospray source in the multiple reaction monitoring (MRM) mode. The analytes were quantified from the summed total ion value of their two most intense molecular transitions. This is another novel method leading to increased sensitivity and precision. A simple liquid-liquid extraction with 2X1.0 ml n-hexane/ethyl acetate/dimethyloctyl an-fine (90:10:0.05, v/v) was utilized. The method was validated in terms of recovery, linearity, accuracy and precision (within- and between-assay variation). The recoveries from spiked control samples were greater than or equal to90 and 50% for bulaquine and primaquine, respectively. Linearity in plasma was observed over a dynamic range of 1.56-400 and 3.91-1000 ng/ml for bulaquine and primaquine, respectively. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 50 条
  • [41] Liquid Chromatography-Tandem Mass Spectrometric Assay for AZD9291 in Rat Plasma
    Su, Xin-juan
    Hu, Jie
    Zhang, Lei
    Li, Li
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (04): : 737 - 742
  • [42] Liquid chromatography-tandem mass spectrometric method for determination of E121 in mouse plasma and its application to pharmacokinetics
    Mater, Kama M.
    El-Hashim, Ahmed Z.
    Edafiogho, Ivan O.
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (13) : 1888 - 1896
  • [43] Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma
    Zhang, Mengqi
    Liu, Haiming
    He, Jiajin
    Gui, Yuzhou
    Qian, Hongjie
    Jia, Jingying
    Yu, Chen
    Wang, Zhen
    Shen, Jing Shan
    Liu, Gangyi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 191
  • [44] Liquid chromatography-tandem mass spectrometric assay for the ALK inhibitor crizotinib in mouse plasma
    Sparidans, Rolf W.
    Tang, Seng Chuan
    Nguyen, Luan N.
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 150 - 154
  • [45] Liquid Chromatography Tandem Mass Spectrometric Assay for the Determination of Forskolin in Rat Plasma
    Guo Ji-Fen
    Lu Bing
    Meng Fan-Hua
    Zhao Yi-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 399 - 402
  • [46] Simultaneous quantitation of hydrochlorothiazide and metoprolol in human plasma by liquid chromatography-tandem mass spectrometry
    Gao, Feng
    Zhang, Mengliang
    Cui, Xiangyong
    Wang, Zhonghua
    Sun, Yantong
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (01) : 149 - 154
  • [47] Liquid chromatography-tandem mass spectrometry for the simultaneous quantitation of enmetazobactam and cefepime in human plasma
    Mameli, M.
    Vezzelli, A.
    Verze', S.
    Biondi, S.
    Motta, P.
    Greco, A.
    Michi, M.
    Breda, M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 655 - 662
  • [48] Evaluation of a Novel Commercial Assay for the Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus by Liquid Chromatography-Tandem Mass Spectrometric Assay
    Becker, Susen
    Thiery, Joachim
    Ceglarek, Uta
    THERAPEUTIC DRUG MONITORING, 2013, 35 (01) : 129 - 132
  • [49] Simultaneous determination of fraxin and its metabolite, fraxetin, in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Wang, Haidong
    Xiao, Bingxin
    Hao, Zhiqiang
    Sun, Zengxian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1017 : 70 - 74
  • [50] Optimisation of a liquid chromatography-tandem mass spectrometric method for the determination of acrylamide in foods
    Govaert, Y
    Arisseto, A
    Van Loco, J
    Scheers, E
    Fraselle, S
    Weverbergh, E
    Degroodt, JM
    Goeyens, L
    ANALYTICA CHIMICA ACTA, 2006, 556 (02) : 275 - 280