Liquid chromatography-tandem mass spectrometric assay with a novel method of quantitation for the simultaneous determination of bulaquine and its metabolite, primaquine, in monkey plasma

被引:20
|
作者
Nitin, M
Rajanikanth, M
Lal, J
Madhusudanan, KP
Gupta, RC [1 ]
机构
[1] Cent Drug Res Inst, Pharmacokinet & Metab Div, Lucknow 226001, Uttar Pradesh, India
[2] Cent Drug Res Inst, Reg Sophisticated Instrumentat Ctr, Lucknow 226001, Uttar Pradesh, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 793卷 / 02期
关键词
bulaquine; primaquine;
D O I
10.1016/S1570-0232(03)00322-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective liquid chromatography-tandemmass spectrometry method (LC-MS-MS) for the simultaneous estimation of bulaquine and primaquine has been developed and validated in monkey plasma. The mobile phase consisted of acetonitrile/ammonium acetate buffer (20 mM, pH 6) (50:50 v/v) at a flow-rate of 1 ml/min. The chromatographic separations were achieved on two spheri cyano columns (5 mum, 30X4.6 mm I.D.) connected in series. The quantitation was carried out using a Micromass LC-MS-MS with an electrospray source in the multiple reaction monitoring (MRM) mode. The analytes were quantified from the summed total ion value of their two most intense molecular transitions. This is another novel method leading to increased sensitivity and precision. A simple liquid-liquid extraction with 2X1.0 ml n-hexane/ethyl acetate/dimethyloctyl an-fine (90:10:0.05, v/v) was utilized. The method was validated in terms of recovery, linearity, accuracy and precision (within- and between-assay variation). The recoveries from spiked control samples were greater than or equal to90 and 50% for bulaquine and primaquine, respectively. Linearity in plasma was observed over a dynamic range of 1.56-400 and 3.91-1000 ng/ml for bulaquine and primaquine, respectively. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 50 条
  • [21] Simultaneous determination of flupirtine and its major active metabolite in human plasma by liquid chromatography-tandem mass spectrometry
    Chen, XY
    Zhong, DF
    Xu, HY
    Schug, B
    Blume, H
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 195 - 202
  • [22] Simultaneous determination of alflutinib and its active metabolite in human plasma using liquid chromatography-tandem mass spectrometry
    Liu, Xiaoyun
    Li, Wei
    Zhang, Yifan
    Jian, Yong
    Zhao, Qianyu
    Zhong, Dafang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 176
  • [23] Determination of cryptotanshinone and its metabolite in rat plasma by liquid chromatography-tandem mass spectrometry
    Song, M
    Hang, TJ
    Zhang, ZHX
    Du, R
    Chen, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02): : 205 - 209
  • [24] Development and validation of high-throughput liquid chromatography-tandem mass spectrometric method for simultaneous quantification of Clopidogrel and its metabolite in human plasma
    Reddy S, Raghunadha
    Divi, Koteswara Rao
    Chandiran, I. Sarath
    Jayaveera, K. N.
    Naidu, Y. K.
    Reddy, M. P. Kalyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (3-4): : 502 - 508
  • [25] Simultaneous determination of polydatin and its metabolite in plasma by liquid chromatography/tandem mass spectrometry
    Yang Run-Tao
    Zhou Si-Yuan
    Zhang Xiang
    Teng Zeng-Hui
    Zhang Bang-Le
    Liu Xin-You
    Yang Xi
    Zhang Li-Juan
    Mei Qi-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (09) : 1309 - 1313
  • [26] Liquid chromatography-tandem mass spectrometric assay for the multikinase inhibitor regorafenib in plasma
    Luethi, Dino
    Durmus, Selvi
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    Sparidans, Rolf W.
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (10) : 1366 - 1370
  • [27] Liquid chromatography-tandem mass spectrometric assay for the PARP inhibitor rucaparib in plasma
    Sparidans, Rolf W.
    Durmus, Selvi
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 626 - 629
  • [28] Liquid chromatography-tandem mass spectrometry assay for the quantitation of β-dihydroartemisinin in rat plasma
    Xing, Jie
    Yan, Hong-Xia
    Wang, Rui-Li
    Zhang, Li-Feng
    Zhang, Shu-Qiu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 202 - 207
  • [29] Validation of a simple liquid chromatography-tandem mass spectrometric method for the determination of propiverine hydrochloride and its N-oxide metabolite in human plasma
    Komoto, I
    Yoshida, K
    Matsushima, E
    Yamashita, K
    Aikawa, T
    Akashi, S
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 141 - 147
  • [30] Liquid Chromatography-Tandem Mass Spectrometric Determination of Geniposide in Rat Plasma and its Pharmacokinetic Application
    Jin, Ming Ji
    Kim, In Sook
    Kim, Dong-Hyun
    Yoo, Hye Hyun
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (09): : 2760 - 2764