Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty

被引:0
|
作者
Hofmann, S [1 ]
Romero, J
Roth-Schiffl, E
Albrecht, T
机构
[1] Allgemeines & Orthopaed LKH, A-8852 Stolzlape, Austria
[2] Univ Zurich, Orthopad Klin Balgrist, Zurich, Switzerland
[3] LKH, Abt Radiol, Judenburg, Austria
来源
ORTHOPADE | 2003年 / 32卷 / 06期
关键词
total knee arthroplasty; rotational malalignment; clinical consequences; revision surgery; results;
D O I
10.1007/s00132-003-0503-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rotational alignment of the tibial and femoral component plays an important role in modern total knee replacement surgery. After correct frontal alignment and proper soft tissue balancing, the rotational placement of the components represents the "third dimension" in knee endoprosthetic surgery. Improved surgical techniques with modified instruments and better rotational component positioning will lead to better functional outcomes. Patients with painful total knee arthroplasties (TKA) or early failure without evident classic implantation failures or signs of infection should be evaluated for malrotation of the components. In a prospective study in 26 patients with painful TKA and malrotation of the tibia and/or femur component, revision surgery with exchange of the components was performed. Twenty-five cases showed clinically relevant internal malrotation of the tibial component (circle divide 8.4degrees) and/or femoral component (circle divide 5.6degrees). Only one patient had 10degrees of external malrotation of the femoral component. Combined malrotations of the tibia and femur were found in ten knees (38%). After revision surgery and correction of malrotations, 20 patients (78%) were scored with excellent and good results. Patients with painful TKA resistant to conservative therapy and evident malrotations of the component should be considered for revision surgery with change of the malrotated components.
引用
收藏
页码:469 / +
页数:8
相关论文
共 50 条
  • [31] Failure following revision total knee arthroplasty: infection is the major cause
    S. M. Javad Mortazavi
    Jeremy Molligan
    Matthew S. Austin
    James J. Purtill
    William J. Hozack
    Javad Parvizi
    International Orthopaedics, 2011, 35 : 1157 - 1164
  • [32] Opioid Use as an Early Indication of Total Knee Arthroplasty Failure
    Inacio, Maria C. S.
    Namba, Robert S.
    Pratt, Nicole L.
    Graves, Stephen E.
    Roughead, Elizabeth E.
    Cheetham, Craig T.
    Paxton, Elizabeth W.
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2015, 24 : 296 - 297
  • [33] Effect of rotation of the femoral and tibial components on patellofemoral malalignment in knee arthroplasty
    Kienapfel, H
    Springorum, HP
    Ziegler, A
    Klose, KJ
    Georg, C
    Griss, P
    ORTHOPADE, 2003, 32 (04): : 312 - +
  • [34] ASSESSING ROTATIONAL ALIGNMENT IN TOTAL KNEE ARTHROPLASTY
    ECKHOFF, DG
    PIATT, BE
    GNADINGER, CA
    BLASCHKE, RC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (318) : 176 - 181
  • [35] Femoral Bow Predicts Postoperative Malalignment in Revision Total Knee Arthroplasty
    Sebastian, Arjun S.
    Wilke, Benjamin K.
    Taunton, Michael J.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1605 - 1609
  • [36] Metastatic Carcinoma as an Unusual Cause of Knee Pain After Total Knee Arthroplasty A Case Report
    Fehring, Keith
    Hamilton, William
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03): : 693 - 695
  • [37] Improved design decreases wear in total knee arthroplasty with varus malalignment
    Nishikawa, Kazutaka
    Okazaki, Ken
    Matsuda, Shuichi
    Tashiro, Yasutaka
    Kawahara, Shinya
    Nakahara, Hiroyuki
    Okamoto, Shigetoshi
    Shimoto, Takeshi
    Higaki, Hidehiko
    Iwamoto, Yukihide
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (11) : 2635 - 2640
  • [38] An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components
    Alfonso Manzotti
    Cesare Chemello
    Chris Pullen
    Pietro Cerveri
    Norberto Confalonieri
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2518 - 2522
  • [39] An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components
    Manzotti, Alfonso
    Chemello, Cesare
    Pullen, Chris
    Cerveri, Pietro
    Confalonieri, Norberto
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (11) : 2518 - 2522
  • [40] False malalignment after computer-navigated total knee arthroplasty
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    KNEE, 2021, 30 : 100 - 105