Passive 3D Needle Tip Tracking in Freehand MR-Guided Interventions with Needle Model Visualization

被引:0
|
作者
Schmitt, Sebastian [1 ]
Sobotta, Christian [1 ]
Choli, Morwan [2 ]
Overhoff, Heinrich M. [1 ]
机构
[1] Univ Appl Sci, Westfal Hsch, Med Engn Lab, Gelsenkirchen, Germany
[2] MR Comp GmbH, Testing Serv MR Safety & Compatibil, Gelsenkirchen, Germany
关键词
D O I
10.1007/978-3-662-46224-9_17
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In freehand MR-guided interventions, the monitoring of the current needle position relative to the target is crucial. In this work, a method for fast passive needle tip tracking in 3D is presented. For a true-FISP sequence, it is shown that proper k-space sub-sampling and signal processing allow for an accurate estimation of the needle tip position. A reduction in scan time is achieved by drastically reducing the number of measurements. The calculated needle tip positions are superimposed on a pre-interventional 3D planning volume in form of a needle model to ensure a continuous monitoring of the current needle tip position.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 50 条
  • [31] Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy
    de Battisti, Maxence Borot
    de Senneville, Baudouin Denis
    Maenhout, Metha
    Lagendijk, Jan J. W.
    van Vulpen, Marco
    Hautvast, Gilion
    Binnekamp, Dirk
    Moerland, Marinus A.
    MEDICAL PHYSICS, 2016, 43 (10) : 5288 - 5297
  • [32] 3D Parametric model of lesion geometry for evaluation of MR-guided radiofrequency ablation therapy
    Lazebnik, RS
    Weinberg, BD
    Breen, MS
    Lewin, JS
    Wilson, DL
    MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 : 360 - 367
  • [33] Automatic Shape-Based 3D Level Set Segmentation for Needle Tracking in 3D TRUS Guided Prostate Brachytherapy
    Yan, P.
    Chao, K.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [34] The 3D Eyeball FEA Model with Needle Rotation
    Wu, Jing
    Nasseri, M. A.
    Eder, M.
    Gavaldon, M. Azqueta
    Lohmann, C. P.
    Knoll, Alois
    3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND TECHNOLOGY - ICBET 2013, 2013, 7 : 4 - 10
  • [35] Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy
    de Battisti, M. Borot
    de Senneville, B. Denis
    Maenhout, M.
    Hautvast, G.
    Binnekamp, D.
    Lagendijk, J. J. W.
    Van Vulpen, M.
    Moerland, M. A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3793 - 3793
  • [36] A novel manipulator for 3D ultrasound guided percutaneous needle insertion
    Bassan, H.
    Hayes, T.
    Patel, R. V.
    Moallem, M.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 617 - 622
  • [37] Use of 3D Gels for Determining MR and Radiation Isocenters in MR-Guided Radiation Therapy
    Lee, H.
    Bosco, G.
    Kadbi, Ni
    Ibbott, G.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [38] Reusable, MR-Visible, and Radiosensitive 3D Dosimeters for MR-Guided Radiation Therapy
    Lee, H.
    Bosco, G.
    Kadbi, M.
    Ibbott, G.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [39] Lesion 3D modeling in transcranial MR-guided focused ultrasound thalamotomy
    Lopez-Aguirre, Miguel
    Caballero-Insaurriaga, Jaime
    Urso, Daniele
    Rodriguez-Rojas, Rafael
    Manez-Miro, Jorge U.
    Del-Alamo, Marta
    Rachmilevitch, Itay
    Martinez-Fernandez, Raul
    Pineda-Pardo, Jose A.
    MAGNETIC RESONANCE IMAGING, 2021, 80 : 71 - 80
  • [40] A simulation technique for 3D MR-guided acoustic radiation force imaging
    Payne, Allison
    de Bever, Josh
    Farrer, Alexis
    Coats, Brittany
    Parker, Dennis L.
    Christensen, Douglas A.
    MEDICAL PHYSICS, 2015, 42 (02) : 674 - 684