Autoradiography in BNCT: a preliminary study for a novel technique

被引:0
|
作者
Ruffolo, MD [1 ]
de la Hoz, AP [1 ]
Saint Martin, G [1 ]
Cruz, GS [1 ]
Bernaola, OA [1 ]
机构
[1] Univ Nacl Gen San Martin, Buenos Aires, DF, Argentina
关键词
nuclear track; BNCT; autoradiography; dosimetry;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to simplify the process and handling of the samples detector-tissue, during the developing of autoradiography process used in BNCT, were herein propose an alternative to conventional techniques. In so we employed: 1.- Thin Makrofol-E and Polyvinil chloride acetate fell as detector and tissue protector respectively. 2.- Two teflon rings to support the samples (detector-protector-tissue) where all the following steps can be carried on minimizing the sample handling. Those rings provide a mechanical support for the external cover of tissue during the etching attack and for the mounting of the glass slide during the microscope observation. 3.- A silicon sealing replacing the glycerol/gelatin is used as tissue protector thus, decreasing the hardening time from 2 days at 4 degreesC to 25 minutes at room temperature. 4.- A drop of fluorescein between the Makrofol E and the slide is included, in order to increasing the track resolution by microscopy.
引用
收藏
页码:876 / 878
页数:3
相关论文
共 50 条
  • [41] A preliminary study on a novel bioaugmentation technique enhancing lactic acid production by mixed cultures fermentation
    Policastro, Grazia
    Carraturo, Federica
    Compagnone, Mariacristina
    Giugliano, Marco
    Guida, Marco
    Luongo, Vincenzo
    Napolitano, Raffaele
    Fabbricino, Massimiliano
    BIORESOURCE TECHNOLOGY, 2021, 340
  • [42] Assessment of a Novel Augmented Closure Technique for Surgical Wounds Associated with Transmetatarsal Amputation A Preliminary Study
    Alexander, Jeffery
    Desai, Vishal
    Denden, Sharif
    Alianello, Nicholas
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2022, 112 (05)
  • [43] Dosimetry of BNCT beams with novel thermoluminescent detectors
    Bilski, P
    Budzanowski, M
    Ochab, E
    Olko, P
    Czopyk, L
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 623 - 626
  • [44] CITATION CLASSIC - IMPROVEMENTS IN THE COATING TECHNIQUE OF AUTORADIOGRAPHY
    KOPRIWA, BM
    CURRENT CONTENTS/LIFE SCIENCES, 1988, (03): : 15 - 15
  • [45] CITATION CLASSIC - IMPROVEMENTS IN THE COATING TECHNIQUE OF AUTORADIOGRAPHY
    KOPRIWA, BM
    CURRENT CONTENTS/ENGINEERING TECHNOLOGY & APPLIED SCIENCES, 1988, (02): : 16 - 16
  • [46] AUTORADIOGRAPHY OF BACTERIA AND STREPTOMYCETACEAE BY STRIPPING FILM TECHNIQUE
    GROSSBARD, E
    NATURE, 1962, 193 (4818) : 853 - &
  • [47] CITATION CLASSIC - IMPROVEMENTS IN THE COATING TECHNIQUE OF AUTORADIOGRAPHY
    KOPRIWA, BM
    CURRENT CONTENTS/PHYSICAL CHEMICAL & EARTH SCIENCES, 1988, (02): : 16 - 16
  • [48] An automatic tooth preparation technique: A preliminary study
    Yuan, Fusong
    Wang, Yong
    Zhang, Yaopeng
    Sun, Yuchun
    Wang, Dangxiao
    Lyu, Peijun
    SCIENTIFIC REPORTS, 2016, 6
  • [49] An automatic tooth preparation technique: A preliminary study
    Fusong Yuan
    Yong Wang
    Yaopeng Zhang
    Yuchun Sun
    Dangxiao Wang
    Peijun Lyu
    Scientific Reports, 6
  • [50] SIMPLE TECHNIQUE FOR AUTORADIOGRAPHY OF CYLINDRICAL POLYACRYLAMIDE GELS
    WATTS, JW
    KING, JM
    SAKAI, F
    ANALYTICAL BIOCHEMISTRY, 1977, 79 (1-2) : 579 - 582