Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People

被引:139
|
作者
Nana, Alisa [1 ,2 ]
Slater, Gary J. [3 ]
Hopkins, Will G. [4 ]
Burke, Louise M. [1 ]
机构
[1] Australian Inst Sport, AIS Sports Nutr, Canberra, ACT, Australia
[2] RMIT Univ, Exercise Metab Grp, Bundoora, Vic, Australia
[3] Univ Sunshine Coast, Maroochydore, Qld, Australia
[4] Auckland Univ Technol, Auckland, New Zealand
来源
关键词
DXA; LEAN MASS; BODY FAT; RELIABILITY; ATHLETES; FOOTBALL SOCCER PLAYERS; SOFT-TISSUE COMPOSITION; FAT MEASUREMENT; SPORTS-MEDICINE; MINERAL-CONTENT; BONE-DENSITY; DXA; MODEL; VALIDATION; PERFORMANCE;
D O I
10.1249/MSS.0b013e318228b60e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
NANA, A., G. J. SLATER, W. G. HOPKINS, and L. M. BURKE. Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 180-189, 2012. Purpose: Dual-energy x-ray absorptiometry (DXA) is becoming a popular tool to measure body composition in athletes, owing to its ease of operation and comprehensive analysis of body composition. This study represents the first systematic investigation of the reliability of DXA measurements of body composition in trained individuals and includes measurements of daily variability as well as the specific effect of the intake of a meal. Methods: Physically active young adults (15 females, 16 males) underwent five whole-body DXA scans during a 2-d period: in the morning after an overnight fast, similar to 5 min later after repositioning on the scanning bed, similar to 8 h later after usual daily activities, and the next morning before and similar to 30 min after consumption of a simple breakfast. Magnitudes of typical (standard) errors of measurement and changes in the mean of DXA measures were assessed by standardization. Results: Repositioning produced trivial typical errors for whole-body composition, whereas regional body composition showed substantial errors. Daily activities and consumption of breakfast generally produced a substantial increase in the typical error and mean of DXA estimates of total and regional lean mass and associated body mass. Conclusions: Having a standardized scanning protocol and fasted subjects is the most practical way to minimize measurement errors. Future studies involving DXA in measuring body composition should report their scanning and analysis protocol with their associated typical errors of measurement so that the level of reliability can be assessed.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [41] Precision of dual energy x-ray absorptiometry for body composition measurements in cats
    Borges, N. C.
    Vasconcellos, R. S.
    Canola, J. C.
    Paula, F. J. A.
    Carciofi, A. C.
    Pereira, G. T.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2008, 60 (01) : 263 - 266
  • [42] Whole-body dual-energy X-ray absorptiometry
    Braillon, Pierre
    PEDIATRIC RADIOLOGY, 2009, 39 (11) : 1256 - 1257
  • [43] Body Fluid Redistribution Affects Dual-Energy X-Ray Absorptiometry Body Composition Scores
    Moncada-Jimenez, Jose
    Carpio-Rivera, Elizabeth
    Chacon-Araya, Yamileth
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 806 - 807
  • [44] Accuracy of dual-energy X-ray absorptiometry (DXA) for determining body composition of rats
    Carroll, WF
    Nagy, TR
    PEDIATRIC RESEARCH, 2002, 51 (04) : 401A - 402A
  • [45] DETECTION OF SMALL CHANGES IN BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOING, SB
    MASSETT, MP
    HALL, MC
    BARE, LA
    ROOT, PA
    WILLIAMS, DP
    LOHMAN, TG
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06): : 845 - 850
  • [46] Body composition by dual-energy X-ray absorptiometry in black compared with white women
    Aloia, JF
    Vaswani, A
    Mikhail, M
    Flaster, ER
    OSTEOPOROSIS INTERNATIONAL, 1999, 10 (02) : 114 - 119
  • [47] Whole-body dual-energy X-ray absorptiometry
    Pierre Braillon
    Pediatric Radiology, 2009, 39 : 1256 - 1257
  • [48] Total Body Bone Measurements in Spinal Osteoporosis by Dual-Energy X-Ray Absorptiometry
    R. M. Revilla
    E. R. Hernández
    L. F. Villa
    C. Seco
    A. Sanchez-Atrio
    H. Rico
    Calcified Tissue International, 1997, 61 : 44 - 47
  • [49] DETERMINATION OF BODY-COMPOSITION - A COMPARISON OF DUAL-ENERGY X-RAY ABSORPTIOMETRY AND HYDRODENSITOMETRY
    JOHANSSON, AG
    FORSLUND, A
    SJODIN, A
    MALLMIN, H
    HAMBRAEUS, L
    LJUNGHALL, S
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (03): : 323 - 326
  • [50] COMPARATIVE-STUDY OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    ALOIA, JF
    VASWANI, A
    MA, RM
    FLASTER, E
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (08) : 1392 - 1397