Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People

被引:139
|
作者
Nana, Alisa [1 ,2 ]
Slater, Gary J. [3 ]
Hopkins, Will G. [4 ]
Burke, Louise M. [1 ]
机构
[1] Australian Inst Sport, AIS Sports Nutr, Canberra, ACT, Australia
[2] RMIT Univ, Exercise Metab Grp, Bundoora, Vic, Australia
[3] Univ Sunshine Coast, Maroochydore, Qld, Australia
[4] Auckland Univ Technol, Auckland, New Zealand
来源
关键词
DXA; LEAN MASS; BODY FAT; RELIABILITY; ATHLETES; FOOTBALL SOCCER PLAYERS; SOFT-TISSUE COMPOSITION; FAT MEASUREMENT; SPORTS-MEDICINE; MINERAL-CONTENT; BONE-DENSITY; DXA; MODEL; VALIDATION; PERFORMANCE;
D O I
10.1249/MSS.0b013e318228b60e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
NANA, A., G. J. SLATER, W. G. HOPKINS, and L. M. BURKE. Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 180-189, 2012. Purpose: Dual-energy x-ray absorptiometry (DXA) is becoming a popular tool to measure body composition in athletes, owing to its ease of operation and comprehensive analysis of body composition. This study represents the first systematic investigation of the reliability of DXA measurements of body composition in trained individuals and includes measurements of daily variability as well as the specific effect of the intake of a meal. Methods: Physically active young adults (15 females, 16 males) underwent five whole-body DXA scans during a 2-d period: in the morning after an overnight fast, similar to 5 min later after repositioning on the scanning bed, similar to 8 h later after usual daily activities, and the next morning before and similar to 30 min after consumption of a simple breakfast. Magnitudes of typical (standard) errors of measurement and changes in the mean of DXA measures were assessed by standardization. Results: Repositioning produced trivial typical errors for whole-body composition, whereas regional body composition showed substantial errors. Daily activities and consumption of breakfast generally produced a substantial increase in the typical error and mean of DXA estimates of total and regional lean mass and associated body mass. Conclusions: Having a standardized scanning protocol and fasted subjects is the most practical way to minimize measurement errors. Future studies involving DXA in measuring body composition should report their scanning and analysis protocol with their associated typical errors of measurement so that the level of reliability can be assessed.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [21] Precision of dual-energy X-ray absorptiometry for determining body composition of rats
    Carroll, WF
    Nagy, TR
    OBESITY RESEARCH, 2001, 9 : 108S - 108S
  • [22] Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
    He, M
    Li, ETS
    Kung, AWC
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (12) : 933 - 937
  • [23] ASSESSMENT OF WHOLE-BODY COMPOSITION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SLOSMAN, DO
    CASEZ, JP
    PICHARD, C
    ROCHAT, T
    FERY, F
    RIZZOLI, R
    BONJOUR, JP
    MORABIA, A
    DONATH, A
    RADIOLOGY, 1992, 185 (02) : 593 - 598
  • [24] Body composition analysis of small pigs by dual-energy X-ray absorptiometry
    Mitchell, AD
    Scholz, AM
    Conway, JM
    JOURNAL OF ANIMAL SCIENCE, 1998, 76 (09) : 2392 - 2398
  • [25] Dual-energy X-ray absorptiometry study of body composition in patients with lipodystrophy
    Valerio, Cynthia M.
    Godoy-Matos, Amelio
    Moreira, Rodrigo O.
    Carraro, Lucia
    Guedes, Erika P.
    Moises, Regina S.
    Mory, Patricia B.
    de Souza, Luciana Lopes
    Russo, Luis Augusto
    Melazzi, Ana Claudia
    DIABETES CARE, 2007, 30 (07) : 1857 - 1859
  • [26] Calibration of dual-energy x-ray absorptiometry estimating pig body composition
    Kipper, M.
    Marcoux, M.
    Andretta, I
    Pomar, C.
    ENERGY AND PROTEIN METABOLISM AND NUTRITION, 2019, 138 : 427 - 429
  • [27] Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis
    Messina, Carmelo
    Monaco, Cristian Giuseppe
    Ulivieri, Fabio Massimo
    Sardanelli, Francesco
    Sconfienza, Luca Maria
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (08) : 1493 - 1498
  • [28] Effects of silicone breast prostheses on the assessment of body composition by dual-energy X-ray absorptiometry
    Madsen, OR
    Lorentzen, JS
    Lauridsen, UB
    Egsmose, C
    Sorensen, OH
    CLINICAL PHYSIOLOGY, 2000, 20 (04): : 279 - 282
  • [29] Comparison of two phantoms for body composition with dual-energy X-ray absorptiometry
    Diessel, E
    Shepherd, JA
    Fuerst, T
    Gonzalez, M
    Genant, HK
    Carew, B
    Looker, A
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 107 - 110
  • [30] Effects of variations in regional composition on soft tissue measurements by dual-energy X-ray absorptiometry
    Milliken, LA
    Going, SB
    Lohman, TG
    INTERNATIONAL JOURNAL OF OBESITY, 1996, 20 (07) : 677 - 682