Investigation on the thermal performance of flat-plate heat pipes with various working fluids under different inclination angles

被引:19
|
作者
Zhang, Bo [1 ]
He, Zhaoyang [1 ]
Wang, Wei [2 ]
Wang, Jin [1 ,3 ]
Mikulcic, Hrvoje [4 ]
Klemes, Jiri Jaromir [3 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Innovat & Entrepreneurial Ctr, Tianjin 300401, Peoples R China
[3] Brno Univ Technol VUT Brno, Fac Mech Engn, NETME Ctr, Sustainable Proc Integrat Lab SPIL, Techn 2896-2, Brno 61669, Czech Republic
[4] Univ Zagreb, Fac Mech Engn & Naval Architecture, Dept Energy Power Engn & Environm, Zagreb 10002, Croatia
基金
中国国家自然科学基金;
关键词
Available online xxxx; Flat -plate heat pipe; Inclination angle; Liquid filling ratio; Thermal resistance; Working fluid; EVAPORATOR RESISTANCE MEASUREMENT; COOLING PERFORMANCE; VISUALIZATION; WATER; NANOFLUID; SECTION; ACETONE; LENGTH; WICK;
D O I
10.1016/j.egyr.2022.06.040
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As one promising high-efficiency equipment, flat-plate heat pipes show an important influence on the thermal management of energy systems. This research experimentally investigates the effects of working fluids (acetone, ethanol, and 1.0 wt% Al2O3 water-based nanofluid), liquid filling ratios (30%, 45%, 60%, and 80%), and inclination angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees) on thermal resistance and equivalent heat transfer coefficient of flat-plate heat pipes under input powers of 15 W, 30 W, 45 W, and 60 W. Results indicate that the flat-plate heat pipe with filling ratio of 60% has the minimum thermal resistance of 2.50 degrees C/W. Compared with filling ratios of 30%, 45%, and 80%, thermal resistance for 60% filling ratio decreases by 42.8%, 27.8%, and 50.7%. The thermal resistances for inclination angles of 0 degrees, 30 degrees, and 90 degrees increase by 88.9%, 2.97%, and 11.8% compared to that with an inclination angle of 60 degrees. The equivalent heat transfer coefficient of the flat-plate heat pipe increases by 90.8% when the inclination angle increases from 0 degrees to 60 degrees due to an effect of gravity. The heat transfer coefficient of the flat-plate heat pipe decreases by 7.2% when the inclination angle increases from 60 degrees to 90 degrees. The thermal resistance of the flat-plate heat pipe using Al2O3 nanofluid as the working medium decreases by 15.2% and 58.7% compared to those with acetone and ethanol. It is observed that partial dryout occurs when the input power is above 30 W. The evaporator with 5 cm length shows the best heat transfer performance of the flat-plate heat pipe.
引用
收藏
页码:8017 / 8026
页数:10
相关论文
共 50 条
  • [41] Ultrahigh Thermal Conductivity of Three-Dimensional Flat-Plate Oscillating Heat Pipes for Electromagnetic Launcher Cooling
    Thompson, Scott M.
    Tessler, Bradley S.
    Ma, Hongbin
    Smith, Douglas E.
    Sobel, Annette
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (05) : 1326 - 1331
  • [42] Visualization and thermal resistance measurement for the sintered mesh-wick evaporator in operating flat-plate heat pipes
    Department of Power Mechanical Engineering, National Tsing Hua University, Hsin-Chu, 300, Taiwan
    Int. J. Heat Mass Transf., 7-8 (1498-1506):
  • [43] Investigation and optimization of design parameters for the thermal performance of a flat-plate solar air heater with sensible heat storage medium
    Selvaraj, Mariyappan
    Sadagopan, Palaniswamy
    Vijayan, Selvaraj
    DESALINATION AND WATER TREATMENT, 2023, 315 : 287 - 303
  • [44] Thermal performance of heat pipe at different internal groove ratios and working fluids: An experimental investigation
    Gomaa, Abdalla
    Rady, Wael Ahmed
    Youssef, Amir Z.
    Elsaid, Ashraf Mimi
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
  • [45] Experimental Investigation and optimization of interconnecting channel design for Flat-Plate Closed-Loop Pulsating heat pipes
    Ebrahimi, Mohsen
    Khalili, Mohammad
    Shafii, Mohammad Behshad
    Moghadamrad, Hossein
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [46] VISUALIZATION AND THERMAL RESISTANCE MEASUREMENT FOR THE SINTERED MESH-WICK EVAPORATOR IN OPERATING FLAT-PLATE HEAT PIPES
    Liou, Jhan-Hong
    Chang, Chia-Wei
    Chao, Chi
    Wong, Shwin-Chung
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER, VOL 3, 2009, : 237 - 243
  • [47] Visualization and thermal resistance measurement for the sintered mesh-wick evaporator in operating flat-plate heat pipes
    Liou, Jhan-Hong
    Chang, Chia-Wei
    Chao, Chi
    Wong, Shwin-Chung
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (7-8) : 1498 - 1506
  • [48] Thermal performance enhancement of flat-plate solar collectors by means of three different nanofluids
    Ziyadanogullari, N. Budak
    Yucel, H. L.
    Yildiz, C.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 55 - 65
  • [49] Simple model for heat transfer analysis of flat-plate heat exchanger with PCM and thermal performance simulation
    Kang, Yanbing
    Zhang, Yinping
    Jiang, Yi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2000, 21 (02): : 121 - 127
  • [50] Numerical Investigation on the Thermal Management Performance of a Liquid-Cooled Cold Plate with Different Working Fluids
    Zhao, Liang
    Lv, Qian
    PROCEEDINGS OF THE SEVENTH ASIA INTERNATIONAL SYMPOSIUM ON MECHATRONICS, VOL II, 2020, 589 : 413 - 423