Investigation on the thermal performance of flat-plate heat pipes with various working fluids under different inclination angles

被引:19
|
作者
Zhang, Bo [1 ]
He, Zhaoyang [1 ]
Wang, Wei [2 ]
Wang, Jin [1 ,3 ]
Mikulcic, Hrvoje [4 ]
Klemes, Jiri Jaromir [3 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Innovat & Entrepreneurial Ctr, Tianjin 300401, Peoples R China
[3] Brno Univ Technol VUT Brno, Fac Mech Engn, NETME Ctr, Sustainable Proc Integrat Lab SPIL, Techn 2896-2, Brno 61669, Czech Republic
[4] Univ Zagreb, Fac Mech Engn & Naval Architecture, Dept Energy Power Engn & Environm, Zagreb 10002, Croatia
基金
中国国家自然科学基金;
关键词
Available online xxxx; Flat -plate heat pipe; Inclination angle; Liquid filling ratio; Thermal resistance; Working fluid; EVAPORATOR RESISTANCE MEASUREMENT; COOLING PERFORMANCE; VISUALIZATION; WATER; NANOFLUID; SECTION; ACETONE; LENGTH; WICK;
D O I
10.1016/j.egyr.2022.06.040
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As one promising high-efficiency equipment, flat-plate heat pipes show an important influence on the thermal management of energy systems. This research experimentally investigates the effects of working fluids (acetone, ethanol, and 1.0 wt% Al2O3 water-based nanofluid), liquid filling ratios (30%, 45%, 60%, and 80%), and inclination angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees) on thermal resistance and equivalent heat transfer coefficient of flat-plate heat pipes under input powers of 15 W, 30 W, 45 W, and 60 W. Results indicate that the flat-plate heat pipe with filling ratio of 60% has the minimum thermal resistance of 2.50 degrees C/W. Compared with filling ratios of 30%, 45%, and 80%, thermal resistance for 60% filling ratio decreases by 42.8%, 27.8%, and 50.7%. The thermal resistances for inclination angles of 0 degrees, 30 degrees, and 90 degrees increase by 88.9%, 2.97%, and 11.8% compared to that with an inclination angle of 60 degrees. The equivalent heat transfer coefficient of the flat-plate heat pipe increases by 90.8% when the inclination angle increases from 0 degrees to 60 degrees due to an effect of gravity. The heat transfer coefficient of the flat-plate heat pipe decreases by 7.2% when the inclination angle increases from 60 degrees to 90 degrees. The thermal resistance of the flat-plate heat pipe using Al2O3 nanofluid as the working medium decreases by 15.2% and 58.7% compared to those with acetone and ethanol. It is observed that partial dryout occurs when the input power is above 30 W. The evaporator with 5 cm length shows the best heat transfer performance of the flat-plate heat pipe.
引用
收藏
页码:8017 / 8026
页数:10
相关论文
共 50 条
  • [31] Thermal Performance of Elliptical Fin-and-Tube Heat Exchangers with Vortex Generator under Various Inclination Angles
    Yucheng Wang
    Wensheng Zhao
    Pengfei Wang
    Jin Jiang
    Xiangyu Luo
    Journal of Thermal Science, 2021, 30 : 257 - 270
  • [32] Thermal Performance of Elliptical Fin-and-Tube Heat Exchangers with Vortex Generator under Various Inclination Angles
    Wang, Yucheng
    Zhao, Wensheng
    Wang, Pengfei
    Jiang, Jin
    Luo, Xiangyu
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (01) : 257 - 270
  • [33] Numerical investigation of solar flat plate collector using different working fluids
    Narayana Prasad P.
    Kalla S.
    International Journal of Ambient Energy, 2023, 44 (01) : 483 - 493
  • [34] Thermal performance of a medium temperature cesium heat pipe at different inclination angles
    Chen, Hong-Xia
    Guo, Yu-Xiang
    Yuan, Da-Zhong
    Ji, Yang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 138
  • [36] THERMAL PERFORMANCE OF FLAT PLATE PULSATING HEAT PIPES WITH MINI- AND MICROCHANNELS
    Jang, Dong Soo
    Lee, Eun-Ji
    Lee, Sang Hun
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (04)
  • [37] Thermal performance analysis of a new multiple flat-plate latent heat storage heat exchanger
    Wang, Meijie
    Liu, Weijie
    JOURNAL OF ENERGY STORAGE, 2024, 98
  • [38] Cooling performance of flat plate heat pipes with different liquid filling ratios
    Chen, Jung-Shun
    Chou, Jung-Hua
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 : 874 - 882
  • [39] Theoretical and experimental investigation of the thermal performance of a double exposure flat-plate solar collector
    Nikolic, N.
    Lukic, N.
    SOLAR ENERGY, 2015, 119 : 100 - 113
  • [40] Experimental investigation of the novel BIPV/T system employing micro-channel flat-plate heat pipes
    Wang, Zhangyuan
    Huang, Zicong
    Chen, Fucheng
    Zhao, Xudong
    Guo, Peng
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2018, 39 (05): : 540 - 556