A new rebinning algorithm for 3D PET data

被引:1
|
作者
Erlandsson, Kjell [1 ]
van Heertum, Ronald [1 ]
Mann, J. John [1 ]
机构
[1] Columbia Univ, Dept Psychiat, New York, NY USA
关键词
D O I
10.1109/NSSMIC.2006.353720
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
3D acquisition mode in PET is a way to increase the sensitivity of the scanner. To reconstruct the 3D data it is necessary to use either a fully 3D reconstruction algorithm or, alternatively, a rebinning algorithm followed by 2D reconstruction. The advantages of the 2(nd) approach are higher speed and reduced data size. Rebinning algorithms may become more important in the future with time-of-flight PET due to the increased dimensionality of the projection data. Although two exact rebinning algorithms have been developed, the most commonly used method today is the approximate Fourier rebinning algorithm. These three methods are based on analytic solutions in the frequency domain and involve geometric approximations, which may be significant for some scanner geometries. They also require attenuation corrected data, which can lead to complications since some reconstruction algorithms work better with non-attenuation corrected data. We have developed a novel rebinning algorithm, called reprojection rebinning (RP-RB), which is free from theoretical and geometric approximations as well as from the requirement of attenuation correction. It is based on an initial reconstruction of a 2D data-subset, which results in a somewhat sub-optimal utilization of the oblique data. The results can be improved, however, by an iterative procedure. We have tested RP-RB using simulated phantom data, showing an SD reduction in the central transaxial plane after the 1(st), 2(nd) and 3(rd) iteration by a factor of 3.0, 3.5 and 4.1, respectively, as compared to 2D data only. There was also a very good spatial accuracy in images reconstructed from noiseless data, even for scanner geometries with large acceptance angles.
引用
收藏
页码:3346 / 3350
页数:5
相关论文
共 50 条
  • [31] Efficiency normalization techniques for 3D PET data
    Kinahan, PE
    Townsend, DW
    Bailey, DL
    Sashin, D
    Jadali, F
    Mintun, MA
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1021 - 1025
  • [32] Fourier rebinning of time-of-flight PET data
    Defrise, M
    Casey, ME
    Michel, C
    Conti, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (12): : 2749 - 2763
  • [33] Optimal Rebinning of Time-of-Flight PET Data
    Ahn, Sangtae
    Cho, Sanghee
    Li, Quanzheng
    Lin, Yanguang
    Leahy, Richard M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (10) : 1808 - 1818
  • [34] EVALUATION OF A 3D RECONSTRUCTION ALGORITHM FOR MULTISLICE PET SCANNERS
    CHERRY, SR
    DAHLBOM, M
    HOFFMAN, EJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 779 - 790
  • [35] Self normalization for continuous 3D whole body emission data in 3D PET
    Ishikawa, A
    Kitamura, K
    Mizuta, T
    Tanaka, K
    Amano, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3634 - 3637
  • [36] A new clustering segmentation algorithm of 3D medical data field based on data mining
    Xinwu L.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (04) : 174 - 181
  • [37] Fully-3D binning and Fourier-space rebinning of PET data acquired with rotating planar detectors.
    Kadrmas, DJ
    Di Bella, EV
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 196P - 196P
  • [38] Continuous and discrete data rebinning in time-of-flight PET
    Defrise, Michel
    Panin, Vladimir
    Michel, Christian
    Casey, Michael E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1310 - 1322
  • [39] Comparison between rebinning methods and geometric re-projection for the estimation of missing oblique data in 3D-PET
    Ben Bouallegue, Faycal
    Crouzet, Jean-Francois
    Mariano-Goulart, Denis
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (09) : 821 - 827
  • [40] Self-normalization of emission data in 3D PET
    Univ of Washington, Seattle, United States
    IEEE Trans Nucl Sci, 3 II (709-712):