Comparison of the high vacuum standard parameters computed from two models

被引:0
|
作者
Niewinski, M. [1 ]
机构
[1] Warsaw Univ Technol, Fac Elect & Informat Technol, Inst Microelect & Optoelect, PL-00662 Warsaw, Poland
关键词
high vacuum standards; Monte Carlo; free molecular flow;
D O I
10.1016/j.vacuum.2008.01.032
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the results of analyses of the high vacuum standard obtained with the use of two models: traditional and the new, so-called 'global'. It was found that the assumptions used in the traditional approach i.e. uniform and cosine gas flux density distribution at the orifice plane and the uniform distributions of the gas flux on the calibration and pumping chamber walls, are not fully fulfilled. These effects cause the effective pumping speed calculated with both models to differ and the relative difference equals 4 x 10(-4). Additionally it was found that the uncertainty of the vacuum standard due to the orifice dimensions measurements being imprecisely computed using the global model is twice smaller taking into account the gas beaming effect. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1141 / 1144
页数:4
相关论文
共 50 条
  • [31] COMPARISON OF STANDARD AND HIGH-RESOLUTION DETECTORS IN COMPUTED RADIOGRAPHY UNDER THE SAME INCIDENT DOSE CONDITIONS
    UEDA, K
    YAMAGUCHI, RT
    NISHIHARA, S
    OHMURA, K
    OHTSUKA, A
    YAMAUCHI, S
    YOSHIDA, K
    RADIOLOGY, 1992, 185 : 159 - 159
  • [32] Standard of calibration for vacuum gauges by direct comparison with reference gauge
    Akimichi, Hitoshi
    Shinku/Journal of the Vacuum Society of Japan, 2007, 50 (08) : 512 - 516
  • [33] DESIGN AND EVALUATION OF A PRIMARY HIGH-VACUUM STANDARD
    JITSCHIN, W
    JOUSTEN, K
    WANDREY, D
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1992, 10 (05): : 3344 - 3351
  • [34] COMPARISON BETWEEN STANDARD EVOLUTION MODELS FOR HIGH AMPLITUDE DELTA-SCT STARS
    CLARET, A
    RODRIGUEZ, E
    GARCIA, JM
    REVISTA MEXICANA DE ASTRONOMIA Y ASTROFISICA, 1990, 21 (SI) : 389 - 390
  • [35] Changes in Parameters after High Tibial Osteotomy: Comparison of EOS System and Computed Tomographic Analysis
    Yoo, Hyun-Jin
    Choi, Jae-Kyu
    Heo, Youn-Moo
    Moon, Sung-Jun
    Oh, Byung-Hak
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (17)
  • [36] COMPARISON OF HIGH VACUUM STILLS AND TENSIMETERS
    HICKMAN, KCD
    TREVOY, DJ
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1952, 44 (08): : 1903 - 1911
  • [37] A comparison of standard coherence models for inflow turbulence with estimates from field measurements
    Saranyasoontorn, K
    Manuel, L
    Veers, PS
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 1069 - 1082
  • [38] Accurate Induction Machines Efficiency Mapping Computed by Standard Test Parameters
    Stiscia, Ornella
    Rubino, Sandro
    Vaschetto, Silvio
    Cavagnino, Andrea
    Tenconi, Alberto
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (03) : 3522 - 3532
  • [39] Estimation of Wind Power Extraction from Kites Flying at High Altitudes Comparison of Two Mathematical Models
    Sanno, Kumari
    Rao, K. V. S.
    PROCEEDINGS OF 2014 1ST INTERNATIONAL CONFERENCE ON NON CONVENTIONAL ENERGY (ICONCE 2014), 2014, : 193 - 197
  • [40] Comparison of the quality of two ECRIS vacuum stands
    Pivarc, J
    Tumanov, KD
    Kutner, VB
    Ivanenko, AI
    Pivarc, J
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 3604 - 3606