Comparison of the high vacuum standard parameters computed from two models

被引:0
|
作者
Niewinski, M. [1 ]
机构
[1] Warsaw Univ Technol, Fac Elect & Informat Technol, Inst Microelect & Optoelect, PL-00662 Warsaw, Poland
关键词
high vacuum standards; Monte Carlo; free molecular flow;
D O I
10.1016/j.vacuum.2008.01.032
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the results of analyses of the high vacuum standard obtained with the use of two models: traditional and the new, so-called 'global'. It was found that the assumptions used in the traditional approach i.e. uniform and cosine gas flux density distribution at the orifice plane and the uniform distributions of the gas flux on the calibration and pumping chamber walls, are not fully fulfilled. These effects cause the effective pumping speed calculated with both models to differ and the relative difference equals 4 x 10(-4). Additionally it was found that the uncertainty of the vacuum standard due to the orifice dimensions measurements being imprecisely computed using the global model is twice smaller taking into account the gas beaming effect. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1141 / 1144
页数:4
相关论文
共 50 条
  • [21] Comparison of two models to estimate genetic parameters for number of born alive in pigs
    Konta, Ayane
    Ogawa, Shinichiro
    Kimata, Makoto
    Ishii, Kazuo
    Uemoto, Yoshinobu
    Satoh, Masahiro
    ANIMAL SCIENCE JOURNAL, 2020, 91 (01)
  • [22] Comparison of high-resolution and standard ECG parameters of myocardial ischemia during PTCA
    Lander, P
    Gomis, P
    Gates, K
    Hartman, G
    Lazzara, R
    Wagner, G
    JOURNAL OF ELECTROCARDIOLOGY, 1996, 29 : 167 - 167
  • [23] The interacting vacuum and tensions: A comparison of theoretical models
    Sebastianutti, Marco
    Hogg, Natalie B.
    Bruni, Marco
    PHYSICS OF THE DARK UNIVERSE, 2024, 46
  • [24] COMPARISON OF LATTICE-PARAMETERS OBTAINED FROM AN INTERNAL SILICON MONOCRYSTAL STANDARD
    HARTWIG, J
    BAKMISIUK, J
    BERGER, H
    BRUHL, HG
    OKADA, Y
    GROSSWIG, S
    WOKULSKA, K
    WOLF, J
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1994, 142 (01): : 19 - 26
  • [26] Comparison of Computed 88% TCP Dose for SBRT of NSCLC From Different Models
    Ruggieri, R.
    Stavreva, N.
    Naccarato, S.
    Alongi, F.
    Nahum, A. E.
    Stavrev, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S896 - S897
  • [27] Cosmological constraints on two vacuum decay models
    Yang, Yupeng
    Wang, Yicheng
    Dai, Xinyi
    EUROPEAN PHYSICAL JOURNAL C, 2025, 85 (03):
  • [28] Comparison of ERMI results for dust collected from homes by an electrostatic cloth and by the standard vacuum method
    Vesper, Stephen
    Wymer, Larry
    Cox, David
    Dewalt, Gary
    Pinzer, Eugene
    Friedman, Warren
    Ashley, Peter J.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2021, 18 (09) : 423 - 429
  • [29] Comparison of Two Realisations of a Power Standard
    Budovsky, I.
    Gubler, G. B.
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [30] Standard setting: Comparison of two methods
    George S.
    Haque M.S.
    Oyebode F.
    BMC Medical Education, 6 (1)