Comparison of the high vacuum standard parameters computed from two models

被引:0
|
作者
Niewinski, M. [1 ]
机构
[1] Warsaw Univ Technol, Fac Elect & Informat Technol, Inst Microelect & Optoelect, PL-00662 Warsaw, Poland
关键词
high vacuum standards; Monte Carlo; free molecular flow;
D O I
10.1016/j.vacuum.2008.01.032
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the results of analyses of the high vacuum standard obtained with the use of two models: traditional and the new, so-called 'global'. It was found that the assumptions used in the traditional approach i.e. uniform and cosine gas flux density distribution at the orifice plane and the uniform distributions of the gas flux on the calibration and pumping chamber walls, are not fully fulfilled. These effects cause the effective pumping speed calculated with both models to differ and the relative difference equals 4 x 10(-4). Additionally it was found that the uncertainty of the vacuum standard due to the orifice dimensions measurements being imprecisely computed using the global model is twice smaller taking into account the gas beaming effect. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1141 / 1144
页数:4
相关论文
共 50 条
  • [1] Performance comparison of an extrapolation chamber in computed tomography standard beams of two laboratories
    Castro, Maysa C.
    Silva, Natalia F.
    Santos, William S.
    Caldas, Linda V. E.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [2] Development of the Vacuum Comparison Standard Device
    Zhang Shufeng
    Song Ruihai
    Gao Ming
    Wang Huan
    Jia Junwei
    Tian Hulin
    18TH INTERNATIONAL VACUUM CONGRESS (IVC-18), 2012, 32 : 78 - 87
  • [3] Sensitivity of high vacuum standard parameters to the share of molecule specular reflections in the gas scattering
    Niewinski, M.
    Szwemin, P.
    VACUUM, 2008, 82 (10) : 1099 - 1102
  • [4] Comparison of Two Standard Physical Models of GaN HEMTs: MVSG and ASM
    Ma, Shuqi
    Liu, Jun
    Wang, Jie
    Xia, Ying
    2021 IEEE MTT-S INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2021), 2021,
  • [5] VACUUM ALIGNMENT IN COMPOSITE TECHNICOLOR STANDARD MODELS
    LUTY, MA
    PHYSICS LETTERS B, 1992, 292 (1-2) : 113 - 118
  • [6] Comparison of Dosimetry Parameters for Two Xoft Axxent Source Models
    Walter, A.
    Anderson, D.
    DeWerd, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E726 - E727
  • [7] The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging
    Aykut, Aktas
    Bumin, Degirmenci
    Omer, Yilmaz
    Mustafa, Kayan
    Meltem, Cetin
    Orhan, Celik
    Nisa, Unlu
    Hikmet, Orhan
    Hakan, Demirtas
    Mert, Koroglu
    AFRICAN HEALTH SCIENCES, 2015, 15 (03) : 925 - 930
  • [8] Comparison of reduced and standard light application in photodynamic treatment in two rabbit models
    Framme, C
    Flucke, B
    Birngruber, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U81 - U81
  • [9] Comparison of Two Parameters Models for clay brick masonry confined by FRP
    Ramaglia, Giancarlo
    Lignola, Gian Piero
    Prota, Andrea
    FRATTURA ED INTEGRITA STRUTTURALE, 2020, 14 (51): : 288 - 312
  • [10] Comparison of two vacuum circuit breaker arc models for small inductive current switching
    Popov, M
    van der Sluis, L
    ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2000, 19 : 438 - 442