Imaging of Arthroplasties: Improved Image Quality and Lesion Detection With Iterative Metal Artifact Reduction, a New CT Metal Artifact Reduction Technique

被引:40
|
作者
Subhas, Naveen [1 ]
Polster, Joshua M. [1 ]
Obuchowski, Nancy A. [2 ]
Primak, Andrew N. [3 ]
Dong, Frank F. [4 ]
Herts, Brian R. [1 ]
Iannotti, Joseph P. [5 ]
机构
[1] Cleveland Clin, Dept Radiol, 9500 Euclid Ave,Ste A21, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44106 USA
[3] Siemens Healthcare, Malvern, PA USA
[4] Cleveland Clin, Sect Med Phys, Cleveland, OH 44106 USA
[5] Cleveland Clin, Dept Orthoped Surg, Cleveland, OH 44106 USA
关键词
artifacts; CT; metallic hardware; techniques; COMPUTED-TOMOGRAPHY; HIP PROSTHESES; RECONSTRUCTIONS; VISUALIZATION;
D O I
10.2214/AJR.15.15850
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 x 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS. For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p <= 0.04) with higher confidence (p <= 0.01) with iMAR than with FBP in the phantom model. CONCLUSION. The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [31] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Watzke, O
    Kalender, WA
    EUROPEAN RADIOLOGY, 2004, 14 (05) : 849 - 856
  • [32] Unintended Consequences: Review of New Artifacts Introduced by Iterative Reconstruction CT Metal Artifact Reduction in Spine Imaging
    Wayer, D. R.
    Kim, N. Y.
    Otto, B. J.
    Grayev, A. M.
    Kuner, A. D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (11) : 1973 - 1975
  • [33] Metal Artifact Reduction with a Deep Image Prior
    Xu, Q.
    Wang, J.
    Shirato, H.
    Xing, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E704 - E704
  • [34] Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling-improved image quality by iterative metal artifact reduction
    Bier, Georg
    Bongers, Malte Niklas
    Hempel, Johann-Martin
    Oergel, Anja
    Hauser, Till-Karsten
    Ernemann, Ulrike
    Hennersdorf, Florian
    NEURORADIOLOGY, 2017, 59 (07) : 649 - 654
  • [35] CT in Patients With External Fixation for Complex Lower Extremity Fractures: Impact of Iterative Metal Artifact Reduction Techniques on Metal Artifact Burden and Subjective Quality
    Brendlin, Andreas Stefan
    Reinert, Christian Philipp
    Baumgartner, Heiko
    Bongers, Malte Niklas
    Thomas, Christoph
    Afat, Saif
    Springer, Fabian
    Almansour, Haidara
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 300 - 309
  • [36] Metal artifact reduction in CT using fusion based prior image
    Wang, Jun
    Wang, Shijie
    Chen, Yang
    Wu, Jiasong
    Coatrieux, Jean-Louis
    Luo, Limin
    MEDICAL PHYSICS, 2013, 40 (08)
  • [37] Metal Artifact Reduction in CT images of Head by Image Processing Techniques
    Safdari, Mohsen
    Karimian, Alireza
    Yazdchi, Mohammadreza
    2011 INTERNATIONAL CONFERENCE ON PHYSICS SCIENCE AND TECHNOLOGY (ICPST), 2011, 22 : 209 - 211
  • [38] Development of a CT Metal Artifact Reduction Technique Based On Deep Learning
    Lee, J.
    Cho, H.
    Kim, H.
    Chae, H.
    Ye, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E500 - E500
  • [39] Fast iterative algorithm for metal artifact reduction in X-ray CT
    Wang, G
    Frei, T
    Vannier, MW
    ACADEMIC RADIOLOGY, 2000, 7 (08) : 607 - 614
  • [40] Metal pin artifact reduction with masked iterative nano-CT reconstruction
    Li, Mengzhou
    Cooley, Victoria
    Nikitin, Viktor
    Stock, Stuart R.
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242