Imaging of Arthroplasties: Improved Image Quality and Lesion Detection With Iterative Metal Artifact Reduction, a New CT Metal Artifact Reduction Technique

被引:40
|
作者
Subhas, Naveen [1 ]
Polster, Joshua M. [1 ]
Obuchowski, Nancy A. [2 ]
Primak, Andrew N. [3 ]
Dong, Frank F. [4 ]
Herts, Brian R. [1 ]
Iannotti, Joseph P. [5 ]
机构
[1] Cleveland Clin, Dept Radiol, 9500 Euclid Ave,Ste A21, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44106 USA
[3] Siemens Healthcare, Malvern, PA USA
[4] Cleveland Clin, Sect Med Phys, Cleveland, OH 44106 USA
[5] Cleveland Clin, Dept Orthoped Surg, Cleveland, OH 44106 USA
关键词
artifacts; CT; metallic hardware; techniques; COMPUTED-TOMOGRAPHY; HIP PROSTHESES; RECONSTRUCTIONS; VISUALIZATION;
D O I
10.2214/AJR.15.15850
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 x 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS. For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p <= 0.04) with higher confidence (p <= 0.01) with iMAR than with FBP in the phantom model. CONCLUSION. The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [21] Metal artifact reduction for improving quantitative SPECT/CT imaging
    Takahiro Konishi
    Takayuki Shibutani
    Koichi Okuda
    Hiroto Yoneyama
    Riku Moribe
    Masahisa Onoguchi
    Kenichi Nakajima
    Seigo Kinuya
    Annals of Nuclear Medicine, 2021, 35 : 291 - 298
  • [22] Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling—improved image quality by iterative metal artifact reduction
    Georg Bier
    Malte Niklas Bongers
    Johann-Martin Hempel
    Anja Örgel
    Till-Karsten Hauser
    Ulrike Ernemann
    Florian Hennersdorf
    Neuroradiology, 2017, 59 : 649 - 654
  • [23] Automated-Adaptive Iterative Metal Artifact Reduction: Quantitative Evaluation of Streak Artifact Reduction When Reconstructing CT Images in Presence of Metal
    Mistry, N.
    Duba, I.
    Halaweish, A.
    Schmidt, B.
    Hofmann, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E637 - E637
  • [24] Metal Artifact Reduction
    Brown, Norman Lee
    Mistry, N.
    Maniawski, P.
    Angel, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3070 - 3070
  • [25] Artifact Reduction in the Diagnosis of Vasospasm in Computed Tomographic Perfusion: Potential of Iterative Metal Artifact Reduction
    Hauser, Till-Karsten
    Oergel, Anja
    Hurth, Helene
    Ernemann, Ulrike
    Seeger, Achim
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (04) : 553 - 558
  • [26] Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
    Abdoli, Mehrsima
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    MEDICAL PHYSICS, 2012, 39 (06) : 3343 - 3360
  • [27] CLIMAR: classified linear interpolation based metal artifact reduction for severe metal artifact reduction in x-ray CT imaging
    Yoon, Huisu
    Lee, Kyoung-Yong
    Bechwati, Ibrahim
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [28] Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software
    Pessis, Eric
    Sverzut, Jean-Michel
    Campagna, Raphael
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 446 - 455
  • [29] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [30] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Oliver Watzke
    Willi A. Kalender
    European Radiology, 2004, 14 : 849 - 856