Lead isotopic compositions of environmental certified reference materials for an inter-laboratory comparison of lead isotope analysis

被引:16
|
作者
Aung, NN [1 ]
Uryu, T [1 ]
Yoshinaga, J [1 ]
机构
[1] Univ Tokyo, Inst Environm Studies, Tokyo 1130033, Japan
关键词
D O I
10.2116/analsci.20.195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lead isotope ratios, viz. Pb-207/Pb-206 and Pb-208/Pb-206, of the commercially available certified reference materials (CRMs) issued in Japan are presented with an objective to provide a data set, which will be useful for the quality assurance of analytical procedures, instrumental performance and method validation of the laboratories involved in environmental lead isotope ratio analysis. The analytical method used in the present study was inductively coupled plasma quadrupole mass spectrometry (ICPQMS) preceded by acid digestion and with/without chemical separation of lead from the matrix. The precision of the measurements in terms of the relative standard deviation (RSD) of triplicated analyses was 0.19% and 0.14%, for Pb-207/Pb-206 and Pb-208/Pb-206, respectively. The trueness of lead isotope ratio measurements of the present study was tested with a few CRMs, which have been analyzed by other analytical methods and reported in various literature. The lead isotopic ratios of 18 environmental matrix CRMs (including 6 CRMs analyzed for our method validation) are presented and the distribution of their ratios is briefly discussed.
引用
收藏
页码:195 / 198
页数:4
相关论文
共 50 条
  • [21] Inter-laboratory calibration of new silver orthophosphate comparison materials for the stable oxygen isotope analysis of phosphates
    Halas, Stanislaw
    Skrzypek, Grzegorz
    Meier-Augenstein, Wolfram
    Pelc, Andrzej
    Kemp, Helen F.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (05) : 579 - 584
  • [22] INTER-LABORATORY VARIATION IN MEASUREMENT OF BLOOD-LEAD LEVELS
    BROWNE, RC
    ELLIS, RW
    WEIGHTMAN, D
    LANCET, 1974, 2 (7889): : 1112 - 1113
  • [23] ENVIRONMENTAL LEAD - NEED FOR REFERENCE MATERIALS
    SUBRAMANIAN, KS
    IYENGAR, GV
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (1-2): : 232 - 235
  • [24] Lead contamination and transfer in urban environmental compartments analyzed by lead levels and Isotopic compositions
    Hu, Xin
    Sun, Yuanyuan
    Ding, Zhuhong
    Zhang, Yun
    Wu, Jichun
    Lian, Hongzhen
    Wang, Tijian
    ENVIRONMENTAL POLLUTION, 2014, 187 : 42 - 48
  • [25] Design of a Reference Device for Surge Immunity Inter-laboratory Comparison
    Tas, Emrah
    Pythoud, Frederic
    Muehlemann, Beat
    2018 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2018, : 482 - 487
  • [26] Design of a Reference Device for Radiated Immunity Inter-laboratory Comparison
    Pythoud, Frederic
    Tas, Emrah
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,
  • [27] Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR
    Dobnik, David
    Demsar, Tina
    Huber, Ingrid
    Gerdes, Lars
    Broeders, Sylvia
    Roosens, Nancy
    Debode, Frederic
    Berben, Gilbert
    Zel, Jana
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (01) : 211 - 221
  • [28] Analysis of lead isotope-ratios in standard reference materials.
    Givler, KA
    Foust, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U71 - U71
  • [29] Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR
    David Dobnik
    Tina Demšar
    Ingrid Huber
    Lars Gerdes
    Sylvia Broeders
    Nancy Roosens
    Frederic Debode
    Gilbert Berben
    Jana Žel
    Analytical and Bioanalytical Chemistry, 2018, 410 : 211 - 221
  • [30] Reference measurements of cadmium and lead contents in candidates for new environmental certified materials by isotope dilution inductively coupled plasma mass spectrometry
    Krata, Agnieszka Anna
    Wojciechowski, Marcin
    Kalabun, Mateusz
    Bulska, Ewa
    MICROCHEMICAL JOURNAL, 2018, 142 : 36 - 42