Comparison of Acuros XB, AAA and PBC dose calculations for clinical treatment plans

被引:0
|
作者
Jones, C. [1 ]
Wells, E. [1 ]
Meehan, C. [1 ]
Trouncer, R. [1 ]
Banks, C. [1 ]
机构
[1] Royal Marsden NHS Fdn Trust, Med Phys, London, England
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1460
引用
收藏
页码:S791 / S791
页数:1
相关论文
共 50 条
  • [21] Dosimetric and Radiobiological Variations in Different Dose Calculation Grid Sizes Between Acuros XB and AAA Algorithms for Prostate VMAT Plans
    Kim, K.
    Chung, J.
    Kang, S.
    Kang, S.
    Kim, J.
    Eom, K.
    Song, C.
    Suh, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E301 - E301
  • [22] Implementation and Validation of 4D Acuros XB Dose Calculations
    Thomas, S.
    Huang, V.
    Milette, M.
    Yuen, C.
    Teke, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3441 - 3441
  • [23] Dose calculation validation of AAA and Acuros XB algorithms in presence of titanium spinal implants
    Tait, J.
    Williams, T.
    Stacey, C. F.
    Hussein, M.
    Clark, C. H.
    Johnson, U.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1364 - S1365
  • [24] Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer
    Tsuruta, Yusuke
    Nakata, Manabu
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Higashimura, Kyoji
    Monzen, Hajime
    Mizowaki, Takashi
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2014, 41 (08) : 189 - 197
  • [25] Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms
    Ong, Chloe C. H.
    Ang, Khong Wei
    Soh, Roger C. X.
    Tin, Kah Ming
    Yap, Jerome H. H.
    Lee, James C. L.
    Bragg, Christopher M.
    MEDICAL DOSIMETRY, 2017, 42 (03) : 216 - 222
  • [26] Comparison of XVMC Monte Carlo Dose Calculations with Eclipse AAA Calculations for RapidArc Plans
    Stelljes, T.
    Alber, M.
    Poppe, B.
    Laub, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3818 - 3818
  • [27] Clinical Implementation of Acuros-XB From AAA for Breast: Changes in Plan Characteristics
    Conroy, L.
    Guebert, A.
    Weppler, S.
    Alghamdi, M.
    Conway, J.
    Harper, L.
    Phan, T.
    Olivotto, I.
    Smith, W.
    Quirk, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2929 - 2929
  • [28] Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc® stereotactic treatments
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    MEDICAL PHYSICS, 2011, 38 (11) : 6228 - 6237
  • [29] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221
  • [30] Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA)
    Rana, S.
    Rogers, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3827 - 3827