Electrochemical DNA biosensor based on gold nanoparticles and partially reduced graphene oxide modified electrode for the detection of Listeria monocytogenes hly gene sequence

被引:57
|
作者
Niu, Xueliang [1 ]
Zheng, Wen [2 ]
Yin, Chunxiao [2 ]
Weng, Wenju [2 ]
Li, Guangjiu [2 ]
Sun, Wei [1 ]
Men, Yongling [1 ]
机构
[1] Hainan Normal Univ, Key Lab Trop Med Plant Chem, Coll Chem & Chem Engn, Minist Educ, Haikou 571158, Hainan, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Partially reduced graphene oxide; Listeria monocytogenes My gene; Carbon ionic liquid electrode; Electrochemical DNA biosensor; GLASSY-CARBON ELECTRODE; FUSION GENE; URIC-ACID; SENSOR; NANOCOMPOSITE; SHEETS; NANOSTRUCTURES; HEMOGLOBIN; DOPAMINE; PROBE;
D O I
10.1016/j.jelechem.2017.10.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study an electrochemical DNA biosensor with gold nanoparticles (AuNPs) and partially reduced graphene oxide (p-RGO) modified electrode was constructed to detect Listeria monocytogenes My gene sequence. AuNPs were electrodeposited on the surface of carbon ionic liquid electrode (CILE) and then p-RGO was further deposited at controlled electroreduction conditions. On the p-RGO surface unreduced oxygenal groups were present and could covalently interact with the amine group at the 5'-end of probe ssDNA through carbodiimide linkage, and the resulted ssDNA/p-RGO/AuNPs/CILE could be used to hybridize with the target ssDNA sequence. Differential pulse voltammetry was applied to monitor the DNA hybridization with methylene blue as electrochemical indicator. Under the optimal conditions, the electrochemical biosensor could be applied to the detection of target DNA sequence in the concentration range from 1.0 x 10(-13)-1.0 x 10(-6) mol/L with the detection limit of 3.17 x 10(-14) mol/L (3S(0)/S). The sensor exhibited good stability and selectivity to one or three-base mismatched ssDNA sequences. PCR sample of Listeria monocytogenes hly gene sequence was successfully detected, indicating the real application of this biosensor.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
  • [41] An electrochemical DNA biosensor based on nitrogen-doped graphene nanosheets decorated with gold nanoparticles for genetically modified maize detection
    Fuli Liu
    Kai Li
    Yukun Zhang
    Jiaqi Ding
    Tingting Wen
    Xinwu Pei
    Yongliang Yan
    Wei Ji
    Jian Liu
    Xiao Zhang
    Liang Li
    Microchimica Acta, 2020, 187
  • [42] An electrochemical DNA biosensor based on nitrogen-doped graphene nanosheets decorated with gold nanoparticles for genetically modified maize detection
    Liu, Fuli
    Li, Kai
    Zhang, Yukun
    Ding, Jiaqi
    Wen, Tingting
    Pei, Xinwu
    Yan, Yongliang
    Ji, Wei
    Liu, Jian
    Zhang, Xiao
    Li, Liang
    MICROCHIMICA ACTA, 2020, 187 (10)
  • [43] Reduced graphene oxide modified with silver nanoparticles for the electrochemical detection of estriol
    Donini, Caruane Alves
    Leme da Silva, Martin Kassio
    Simoes, Rafael Plana
    Cesarino, Ivana
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 809 : 67 - 73
  • [44] A Reduced Graphene Oxide/Gold Nanoparticles Composite Modified Glassy Carbon Electrode as Electrochemical Sensor for Calcium Ions Detection in Bottled Water
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    Oraby, Hesham F.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (06): : 5500 - 5511
  • [45] Reduced Graphene Oxide and Gold Nanoparticles-Modified Electrochemical Aptasensor for Highly Sensitive Detection of Doxorubicin
    Kong, Fanli
    Luo, Jinping
    Jing, Luyi
    Wang, Yiding
    Shen, Huayu
    Yu, Rong
    Sun, Shuai
    Xing, Yu
    Ming, Tao
    Liu, Meiting
    Jin, Hongyan
    Cai, Xinxia
    NANOMATERIALS, 2023, 13 (07)
  • [46] Gold nanoparticles and reduced graphene oxide-amplified label-free DNA biosensor for dasatinib detection
    Tahernejad-Javazmi, Fahimeh
    Shabani-Nooshabadi, Mehdi
    Karimi-Maleh, Hassan
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (19) : 16378 - 16383
  • [47] Acetylcholinesterase biosensor based on a gold nanoparticle-polypyrrole-reduced graphene oxide nanocomposite modified electrode for the amperometric detection of organophosphorus pesticides
    Yang, Yuqi
    Asiri, Abdullah Mohamed
    Du, Dan
    Lin, Yuehe
    ANALYST, 2014, 139 (12) : 3055 - 3060
  • [48] Electrochemical immunoassay based on gold nanoparticles and reduced graphene oxide functionalized carbon ionic liquid electrode
    Yu, Sheng
    Cao, Xiaoyu
    Yu, Meng
    MICROCHEMICAL JOURNAL, 2012, 103 : 125 - 130
  • [49] Evaluation of a Nanocomposite Based on Reduced Graphene Oxide and Gold Nanoparticles as an Electrochemical Platform for Detection of Sulfamethazine
    Silva, Martin
    Cesarino, Ivana
    JOURNAL OF COMPOSITES SCIENCE, 2019, 3 (02):
  • [50] CuNi / β-cyclodextrin / reduced graphene oxide modified electrode for electrochemical detection of dopamine
    Fu, Shanshan
    Zhu, Yuan
    He, Donghui
    Chinese Journal of Analysis Laboratory, 2022, 41 (02) : 125 - 129