Electrochemical DNA biosensor based on gold nanoparticles and partially reduced graphene oxide modified electrode for the detection of Listeria monocytogenes hly gene sequence

被引:57
|
作者
Niu, Xueliang [1 ]
Zheng, Wen [2 ]
Yin, Chunxiao [2 ]
Weng, Wenju [2 ]
Li, Guangjiu [2 ]
Sun, Wei [1 ]
Men, Yongling [1 ]
机构
[1] Hainan Normal Univ, Key Lab Trop Med Plant Chem, Coll Chem & Chem Engn, Minist Educ, Haikou 571158, Hainan, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Partially reduced graphene oxide; Listeria monocytogenes My gene; Carbon ionic liquid electrode; Electrochemical DNA biosensor; GLASSY-CARBON ELECTRODE; FUSION GENE; URIC-ACID; SENSOR; NANOCOMPOSITE; SHEETS; NANOSTRUCTURES; HEMOGLOBIN; DOPAMINE; PROBE;
D O I
10.1016/j.jelechem.2017.10.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study an electrochemical DNA biosensor with gold nanoparticles (AuNPs) and partially reduced graphene oxide (p-RGO) modified electrode was constructed to detect Listeria monocytogenes My gene sequence. AuNPs were electrodeposited on the surface of carbon ionic liquid electrode (CILE) and then p-RGO was further deposited at controlled electroreduction conditions. On the p-RGO surface unreduced oxygenal groups were present and could covalently interact with the amine group at the 5'-end of probe ssDNA through carbodiimide linkage, and the resulted ssDNA/p-RGO/AuNPs/CILE could be used to hybridize with the target ssDNA sequence. Differential pulse voltammetry was applied to monitor the DNA hybridization with methylene blue as electrochemical indicator. Under the optimal conditions, the electrochemical biosensor could be applied to the detection of target DNA sequence in the concentration range from 1.0 x 10(-13)-1.0 x 10(-6) mol/L with the detection limit of 3.17 x 10(-14) mol/L (3S(0)/S). The sensor exhibited good stability and selectivity to one or three-base mismatched ssDNA sequences. PCR sample of Listeria monocytogenes hly gene sequence was successfully detected, indicating the real application of this biosensor.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
  • [21] A reduced graphene oxide based electrochemical biosensor for tyrosine detection
    Wei, Junhua
    Qiu, Jingjing
    Li, Li
    Ren, Liqiang
    Zhang, Xianwen
    Chaudhuri, Jharna
    Wang, Shiren
    NANOTECHNOLOGY, 2012, 23 (33)
  • [22] Electrochemical DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles and graphene for sensitive determination of Klebsiella pneumoniae carbapenemase
    Pan, Hong-zhi
    Yu, Hong-wei
    Wang, Na
    Zhang, Ze
    Wan, Guang-cai
    Liu, Hao
    Guan, Xue
    Chang, Dong
    JOURNAL OF BIOTECHNOLOGY, 2015, 214 : 133 - 138
  • [23] Electrochemical sensor based on graphene doped gold nanoparticles modified electrode for detection of diethylstilboestrol
    Ma, Xinying
    Chen, Meifeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 445 - 450
  • [24] Nano-biosensor based on reduced graphene oxide and gold nanoparticles, for detection of phenylketonuria-associated DNA mutation
    Seifati, Seyed Morteza
    Nasirizadeh, Navid
    Azimzadeh, Mostafa
    IET NANOBIOTECHNOLOGY, 2018, 12 (04) : 417 - 422
  • [25] Electrochemical H2O2 biosensor based on horseradish peroxidase encapsulated protein nanoparticles with reduced graphene oxide-modified gold electrode
    Shin, Jeong-Hyeop
    Lee, Myeong-Jun
    Choi, Jin-Ha
    Song, Ji-ae
    Kim, Tae-Hwan
    Oh, Byung-Keun
    NANO CONVERGENCE, 2020, 7 (01)
  • [26] Electrochemical H2O2 biosensor based on horseradish peroxidase encapsulated protein nanoparticles with reduced graphene oxide-modified gold electrode
    Jeong-Hyeop Shin
    Myeong-Jun Lee
    Jin-Ha Choi
    Ji-ae Song
    Tae-Hwan Kim
    Byung-Keun Oh
    Nano Convergence, 7
  • [27] Electrochemical Biosensor for L-phenylalanine Based on a Gold Electrode Modified with Graphene Oxide Nanosheets and Chitosan
    Naghib, Seyed Morteza
    Rabiee, Mohammad
    Omidinia, Eskandar
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05): : 2341 - 2353
  • [28] An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 144 - 150
  • [29] Ultrasensitive and Highly Selective Electrochemical Biosensor for HIV Gene Detection Based on Amino-Reduced Graphene Oxide and β-cyclodextrin Modified Glassy Carbon Electrode
    Li, Jiawen
    Jin, Xiaoyu
    Feng, Mengmeng
    Huang, Shan
    Feng, Jinrong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (03): : 2727 - 2738
  • [30] Gold nanorods-coated reduced graphene oxide as a modified electrode for the electrochemical sensory detection of NADH
    Marlinda, A. R.
    Sagadevan, Suresh
    Yusoff, N.
    Pandikumar, A.
    Huang, N. M.
    Akbarzadeh, Omid
    Johan, M. R.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 847