Performance analysis of the "MicroMED" Optical Particle Counter in windy conditions

被引:0
|
作者
Mongelluzzo, Giuseppe [1 ,2 ]
Franzese, Gabriele [1 ]
Cozzolino, Fabio [1 ]
Esposito, Francesca [1 ]
Ruggeri, Alan Cosimo [1 ]
Porto, Carmen [1 ]
Molfese, Cesare [1 ]
Silvestro, Simone [1 ,3 ]
Popa, Ciprian Ionut [1 ]
Scaccabarozzi, Diego [4 ]
Saggin, Bortolino [4 ]
Martin-Ortega, Alberto [5 ]
Arruego, Ignacio [5 ]
Ramon De Mingo, Jose [5 ]
Andres Santiuste, Nuria [5 ]
Brienza, Daniele [6 ]
Cortecchia, Fausto [7 ]
Merrison, Jonathan P. [8 ]
Iversen, Jens Jacob [8 ]
机构
[1] INAF Osservatorio Astron Capodimonte, Salita Moiariello 16, I-80131 Naples, Italy
[2] Univ Naples Federico II, Dept Ind Engn, Piazzale Tecchio 80, I-80125 Naples, Italy
[3] Carl Sagan Ctr, SETI Inst, Mountain View, CA USA
[4] Politecn Milano Polo Lecco, Dept Mech Engn, Via Previati 1-c, I-23900 Lecce, Italy
[5] Inst Nacl Tecn Aerosp INTA, Ctra Ajalvir Km 4, Madrid, Spain
[6] INAF Inst Space Astrophys & Planetol IAPS, Via Fosso Cavaliere 100, I-00133 Rome, Italy
[7] INAF Astrophys & Space Sci Observ OAS, Via Piero Gobetti 101, I-40129 Bologna, Italy
[8] Aarhus Univ, Dept Phys & Astron, Ny Munkegade 120,Bldg 1525,222, DK-8000 Aarhus C, Denmark
来源
2021 IEEE 8TH INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (IEEE METROAEROSPACE) | 2021年
关键词
MicroMED instrument; ExoMars; 2020; mission; Airborne Dust; Mars; AWTS II; Europlanet project;
D O I
10.1109/METROAEROSPACE51421.2021.9511691
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The Optical Particle Counter "MicroMED" will be part of the ExoMars 2022 mission and aims to provide the first ever direct measurement of airborne Martian dust. The instrument has been tested at the INAF - OAC premises, where a Martian chamber is present, simulating the Martian environment in terms of pressure, instrument temperature, atmosphere composition and the presence of dust. However, tests in the presence of wind are also needed for the instrument characterization. To this purpose, a test campaign at the AWTS II simulator at the Aarhus University (Denmark) was performed, testing the instrument in the presence of winds up to 15 m/s. Such tests are important since wind is the main agent of landscape modification on Mars. The present work describes the results of such tests, showing the variation of the instrument detecting ability with the wind speed, as well as the influence of temperature on performances.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 50 条
  • [41] ICE PARTICLE-WATER DROPLET DISCRIMINATION WITH AN OPTICAL ICE PARTICLE COUNTER
    SCHEMENAUER, RS
    CURRY, MJ
    JOURNAL OF APPLIED METEOROLOGY, 1979, 18 (02): : 215 - 224
  • [42] Comparative analysis of the thermal insulation performance of a fasade enclosure integrated by vegetation under simultaneous windy and rainy climatic conditions
    Nicolini, Elvira
    Olivieri, Francesca
    Germana, Maria Luisa
    Marcon, Giulia
    Chiodi, Marcello
    Olivieri, Lorenzo
    BUILDING AND ENVIRONMENT, 2023, 239
  • [43] Degradation mechanism of measuring performance of optical particle counter under temperature-pressure coupling effect
    Lu, Lifeng
    Li, Yanbo
    Wang, Yixin
    Wu, Xin
    Xiong, Liling
    Liu, Longlong
    Wei, Liejiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (07)
  • [44] The effect of screens on air-cooled steam condenser performance under windy conditions
    Owen, M. T. F.
    Kroeger, D. G.
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2610 - 2615
  • [45] Investigation of early drying shrinkage of ultrahigh-performance concrete under windy conditions
    Du, Yang
    Zhang, Lifeng
    Ruan, Shaoqin
    Qian, Xiaoqian
    Qian, Kuangliang
    JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [46] Coupled analysis of unsteady aerodynamics and vehicle motion of a road vehicle in windy conditions
    Nakashima, T. (nakashima@hiroshima-u.ac.jp), 1600, Elsevier Ltd (80):
  • [47] Coupled analysis of unsteady aerodynamics and vehicle motion of a road vehicle in windy conditions
    Nakashima, Takuji
    Tsubokura, Makoto
    Vazquez, Mariano
    Owen, Herbert
    Doi, Yasuaki
    COMPUTERS & FLUIDS, 2013, 80 : 1 - 9
  • [48] ON PARTICLE COUNTING ANALYSIS OF A PERSPEX CERENKOV COUNTER
    MAHESH, K
    SRIVASTAVA, BN
    NUCLEAR INSTRUMENTS & METHODS, 1967, 52 (02): : 241 - +
  • [49] A model for aerosol mass concentration using an optical particle counter
    顾芳
    杨娟
    保民
    贺安之
    Chinese Optics Letters, 2008, (03) : 214 - 217
  • [50] Quantitative characterization of noise in the measurement chain of an optical particle counter
    Borggräfe, P
    Trampe, A
    Fissan, H
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 445 - 450